Cargando…

Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development

Complex cell cultures are more representative of in vivo conditions than conventionally used monolayer cultures, and are hence being investigated for predictive screening of therapeutic agents. Poly lactide co-glycolide (PLGA) polymer is frequently used in the development of porous substrates for co...

Descripción completa

Detalles Bibliográficos
Autores principales: Dhamecha, Dinesh, Le, Duong, Movsas, Rachel, Gonsalves, Andrea, Menon, Jyothi U.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7365955/
https://www.ncbi.nlm.nih.gov/pubmed/32754585
http://dx.doi.org/10.3389/fbioe.2020.00799
_version_ 1783560131591536640
author Dhamecha, Dinesh
Le, Duong
Movsas, Rachel
Gonsalves, Andrea
Menon, Jyothi U.
author_facet Dhamecha, Dinesh
Le, Duong
Movsas, Rachel
Gonsalves, Andrea
Menon, Jyothi U.
author_sort Dhamecha, Dinesh
collection PubMed
description Complex cell cultures are more representative of in vivo conditions than conventionally used monolayer cultures, and are hence being investigated for predictive screening of therapeutic agents. Poly lactide co-glycolide (PLGA) polymer is frequently used in the development of porous substrates for complex cell culture. Substrates or scaffolds with highly interconnected, micrometric pores have been shown to positively impact tissue model formation by enhancing cell attachment and infiltration. We report a novel alginate microsphere (AMS)-based controlled pore formation method for the development of porous, biodegradable PLGA microspheres (PPMS), for tissue engineered lung tumor model development. The AMS porogen, non-porous PLGA microspheres (PLGAMS) and PPMS had spherical morphology (mean diameters: 10.3 ± 4, 79 ± 21.8, and 103 ± 30 μm, respectively). The PPMS had relatively uniform pores and a porosity of 45.5%. Degradation studies show that PPMS effectively maintained their structural integrity with time whereas PLGAMS showed shrunken morphology. The optimized cell seeding density on PPMS was 25 × 10(3) cells/mg of particles/well. Collagen coating on PPMS significantly enhanced the attachment and proliferation of co-cultures of A549 lung adenocarcinoma and MRC-5 lung fibroblast cells. Preliminary proof-of-concept drug screening studies using mono- and combination anti-cancer therapies demonstrated that the tissue-engineered lung tumor model had a significantly higher resistance to the tested drugs than the monolayer co-cultures. These studies indicate that the PPMS with controllable pore diameters may be a suitable platform for the development of complex tumor cultures for early in vitro drug screening applications.
format Online
Article
Text
id pubmed-7365955
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-73659552020-08-03 Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development Dhamecha, Dinesh Le, Duong Movsas, Rachel Gonsalves, Andrea Menon, Jyothi U. Front Bioeng Biotechnol Bioengineering and Biotechnology Complex cell cultures are more representative of in vivo conditions than conventionally used monolayer cultures, and are hence being investigated for predictive screening of therapeutic agents. Poly lactide co-glycolide (PLGA) polymer is frequently used in the development of porous substrates for complex cell culture. Substrates or scaffolds with highly interconnected, micrometric pores have been shown to positively impact tissue model formation by enhancing cell attachment and infiltration. We report a novel alginate microsphere (AMS)-based controlled pore formation method for the development of porous, biodegradable PLGA microspheres (PPMS), for tissue engineered lung tumor model development. The AMS porogen, non-porous PLGA microspheres (PLGAMS) and PPMS had spherical morphology (mean diameters: 10.3 ± 4, 79 ± 21.8, and 103 ± 30 μm, respectively). The PPMS had relatively uniform pores and a porosity of 45.5%. Degradation studies show that PPMS effectively maintained their structural integrity with time whereas PLGAMS showed shrunken morphology. The optimized cell seeding density on PPMS was 25 × 10(3) cells/mg of particles/well. Collagen coating on PPMS significantly enhanced the attachment and proliferation of co-cultures of A549 lung adenocarcinoma and MRC-5 lung fibroblast cells. Preliminary proof-of-concept drug screening studies using mono- and combination anti-cancer therapies demonstrated that the tissue-engineered lung tumor model had a significantly higher resistance to the tested drugs than the monolayer co-cultures. These studies indicate that the PPMS with controllable pore diameters may be a suitable platform for the development of complex tumor cultures for early in vitro drug screening applications. Frontiers Media S.A. 2020-07-10 /pmc/articles/PMC7365955/ /pubmed/32754585 http://dx.doi.org/10.3389/fbioe.2020.00799 Text en Copyright © 2020 Dhamecha, Le, Movsas, Gonsalves and Menon. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Dhamecha, Dinesh
Le, Duong
Movsas, Rachel
Gonsalves, Andrea
Menon, Jyothi U.
Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development
title Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development
title_full Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development
title_fullStr Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development
title_full_unstemmed Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development
title_short Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development
title_sort porous polymeric microspheres with controllable pore diameters for tissue engineered lung tumor model development
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7365955/
https://www.ncbi.nlm.nih.gov/pubmed/32754585
http://dx.doi.org/10.3389/fbioe.2020.00799
work_keys_str_mv AT dhamechadinesh porouspolymericmicrosphereswithcontrollableporediametersfortissueengineeredlungtumormodeldevelopment
AT leduong porouspolymericmicrosphereswithcontrollableporediametersfortissueengineeredlungtumormodeldevelopment
AT movsasrachel porouspolymericmicrosphereswithcontrollableporediametersfortissueengineeredlungtumormodeldevelopment
AT gonsalvesandrea porouspolymericmicrosphereswithcontrollableporediametersfortissueengineeredlungtumormodeldevelopment
AT menonjyothiu porouspolymericmicrosphereswithcontrollableporediametersfortissueengineeredlungtumormodeldevelopment