Cargando…
Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development
Complex cell cultures are more representative of in vivo conditions than conventionally used monolayer cultures, and are hence being investigated for predictive screening of therapeutic agents. Poly lactide co-glycolide (PLGA) polymer is frequently used in the development of porous substrates for co...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7365955/ https://www.ncbi.nlm.nih.gov/pubmed/32754585 http://dx.doi.org/10.3389/fbioe.2020.00799 |
_version_ | 1783560131591536640 |
---|---|
author | Dhamecha, Dinesh Le, Duong Movsas, Rachel Gonsalves, Andrea Menon, Jyothi U. |
author_facet | Dhamecha, Dinesh Le, Duong Movsas, Rachel Gonsalves, Andrea Menon, Jyothi U. |
author_sort | Dhamecha, Dinesh |
collection | PubMed |
description | Complex cell cultures are more representative of in vivo conditions than conventionally used monolayer cultures, and are hence being investigated for predictive screening of therapeutic agents. Poly lactide co-glycolide (PLGA) polymer is frequently used in the development of porous substrates for complex cell culture. Substrates or scaffolds with highly interconnected, micrometric pores have been shown to positively impact tissue model formation by enhancing cell attachment and infiltration. We report a novel alginate microsphere (AMS)-based controlled pore formation method for the development of porous, biodegradable PLGA microspheres (PPMS), for tissue engineered lung tumor model development. The AMS porogen, non-porous PLGA microspheres (PLGAMS) and PPMS had spherical morphology (mean diameters: 10.3 ± 4, 79 ± 21.8, and 103 ± 30 μm, respectively). The PPMS had relatively uniform pores and a porosity of 45.5%. Degradation studies show that PPMS effectively maintained their structural integrity with time whereas PLGAMS showed shrunken morphology. The optimized cell seeding density on PPMS was 25 × 10(3) cells/mg of particles/well. Collagen coating on PPMS significantly enhanced the attachment and proliferation of co-cultures of A549 lung adenocarcinoma and MRC-5 lung fibroblast cells. Preliminary proof-of-concept drug screening studies using mono- and combination anti-cancer therapies demonstrated that the tissue-engineered lung tumor model had a significantly higher resistance to the tested drugs than the monolayer co-cultures. These studies indicate that the PPMS with controllable pore diameters may be a suitable platform for the development of complex tumor cultures for early in vitro drug screening applications. |
format | Online Article Text |
id | pubmed-7365955 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-73659552020-08-03 Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development Dhamecha, Dinesh Le, Duong Movsas, Rachel Gonsalves, Andrea Menon, Jyothi U. Front Bioeng Biotechnol Bioengineering and Biotechnology Complex cell cultures are more representative of in vivo conditions than conventionally used monolayer cultures, and are hence being investigated for predictive screening of therapeutic agents. Poly lactide co-glycolide (PLGA) polymer is frequently used in the development of porous substrates for complex cell culture. Substrates or scaffolds with highly interconnected, micrometric pores have been shown to positively impact tissue model formation by enhancing cell attachment and infiltration. We report a novel alginate microsphere (AMS)-based controlled pore formation method for the development of porous, biodegradable PLGA microspheres (PPMS), for tissue engineered lung tumor model development. The AMS porogen, non-porous PLGA microspheres (PLGAMS) and PPMS had spherical morphology (mean diameters: 10.3 ± 4, 79 ± 21.8, and 103 ± 30 μm, respectively). The PPMS had relatively uniform pores and a porosity of 45.5%. Degradation studies show that PPMS effectively maintained their structural integrity with time whereas PLGAMS showed shrunken morphology. The optimized cell seeding density on PPMS was 25 × 10(3) cells/mg of particles/well. Collagen coating on PPMS significantly enhanced the attachment and proliferation of co-cultures of A549 lung adenocarcinoma and MRC-5 lung fibroblast cells. Preliminary proof-of-concept drug screening studies using mono- and combination anti-cancer therapies demonstrated that the tissue-engineered lung tumor model had a significantly higher resistance to the tested drugs than the monolayer co-cultures. These studies indicate that the PPMS with controllable pore diameters may be a suitable platform for the development of complex tumor cultures for early in vitro drug screening applications. Frontiers Media S.A. 2020-07-10 /pmc/articles/PMC7365955/ /pubmed/32754585 http://dx.doi.org/10.3389/fbioe.2020.00799 Text en Copyright © 2020 Dhamecha, Le, Movsas, Gonsalves and Menon. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Dhamecha, Dinesh Le, Duong Movsas, Rachel Gonsalves, Andrea Menon, Jyothi U. Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development |
title | Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development |
title_full | Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development |
title_fullStr | Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development |
title_full_unstemmed | Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development |
title_short | Porous Polymeric Microspheres With Controllable Pore Diameters for Tissue Engineered Lung Tumor Model Development |
title_sort | porous polymeric microspheres with controllable pore diameters for tissue engineered lung tumor model development |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7365955/ https://www.ncbi.nlm.nih.gov/pubmed/32754585 http://dx.doi.org/10.3389/fbioe.2020.00799 |
work_keys_str_mv | AT dhamechadinesh porouspolymericmicrosphereswithcontrollableporediametersfortissueengineeredlungtumormodeldevelopment AT leduong porouspolymericmicrosphereswithcontrollableporediametersfortissueengineeredlungtumormodeldevelopment AT movsasrachel porouspolymericmicrosphereswithcontrollableporediametersfortissueengineeredlungtumormodeldevelopment AT gonsalvesandrea porouspolymericmicrosphereswithcontrollableporediametersfortissueengineeredlungtumormodeldevelopment AT menonjyothiu porouspolymericmicrosphereswithcontrollableporediametersfortissueengineeredlungtumormodeldevelopment |