Cargando…
Radial Meniscal Tears Are Best Repaired by a Modified “Cross” Tie-Grip Suture Based on a Biomechanical Comparison of 4 Repair Techniques in a Porcine Model
BACKGROUND: The tie-grip suture can fix radial tears more rigidly than simple conventional sutures. However, one shortcoming is the residual gap at the central margin of the tear. The tie-grip suture was modified to address this issue and named the “cross tie-grip suture.” PURPOSE/HYPOTHESIS: The pu...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7366409/ https://www.ncbi.nlm.nih.gov/pubmed/32728592 http://dx.doi.org/10.1177/2325967120935810 |
Sumario: | BACKGROUND: The tie-grip suture can fix radial tears more rigidly than simple conventional sutures. However, one shortcoming is the residual gap at the central margin of the tear. The tie-grip suture was modified to address this issue and named the “cross tie-grip suture.” PURPOSE/HYPOTHESIS: The purpose of this study was to compare the suture stability and strength among 4 suturing techniques: the original tie-grip, cross tie-grip, and 2 conventional sutures (double horizontal and cross). It was hypothesized that the cross tie-grip suture would show the least displacement and resist the greatest maximum load. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 40 fresh-frozen porcine knees were dissected to acquire 80 menisci; 20 menisci were tested in each suture group. A radial tear was created at the middle third of the meniscal body. Repair was performed with the following: original tie-grip, cross tie-grip, double horizontal, and cross sutures. The mechanical strength of sutured menisci was evaluated using a tensile testing machine. All menisci underwent submaximal loading and load to failure. The gap distance and ultimate failure load were compared using analysis of variance. The failure mode was recorded after load-to-failure testing. RESULTS: Displacement after 500 cycles was significantly smaller in the cross tie-grip group (0.4 ± 0.3 mm) compared with the tie-grip (0.9 ± 0.6 mm), double horizontal (1.2 ± 0.7 mm), and cross suture groups (1.4 ± 0.6 mm) (P < .05). The ultimate failure load was significantly greater in the cross tie-grip (154.9 ± 29.0 N) and tie-grip (145.2 ± 39.1 N) groups compared with the double horizontal (81.2 ± 19.9 N) and cross suture groups (87.3 ± 17.7 N) (P < .05). Tissue failure was the most common mode of failure in all groups. CONCLUSION: Upon repair of radial meniscal tears, the cross tie-grip suture showed less displacement compared with that of the tie-grip, double horizontal, and cross sutures and demonstrated equivalent load to failure to that of the tie-grip suture at time zero. CLINICAL RELEVANCE: The cross tie-grip suture provided high resistance to displacement after repair of radial tears and may be advantageous in healing for radial meniscal tears. |
---|