A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators
BACKGROUND: This unblinded randomised crossover study compares two endotracheal tube introducers (ETIs): the FROVA and the “Flexible Tip Bougie” (FTB), in an airway manikin mimicking difficult intubation with a percentage of glottic opening view of 30%. Participants were Emergency Medicine and Anaes...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7366560/ https://www.ncbi.nlm.nih.gov/pubmed/32680456 http://dx.doi.org/10.1186/s12245-020-00298-6 |
_version_ | 1783560243968475136 |
---|---|
author | Cormack, John Langley, Bridget Bhanabhai, Louisa-Rose Kluger, Roman |
author_facet | Cormack, John Langley, Bridget Bhanabhai, Louisa-Rose Kluger, Roman |
author_sort | Cormack, John |
collection | PubMed |
description | BACKGROUND: This unblinded randomised crossover study compares two endotracheal tube introducers (ETIs): the FROVA and the “Flexible Tip Bougie” (FTB), in an airway manikin mimicking difficult intubation with a percentage of glottic opening view of 30%. Participants were Emergency Medicine and Anaesthesia trainees with recent experience of less than twenty patient intubations. The primary outcome was time to intubation, further divided into time taken to pass the ETI and time to railroad the endotracheal tube (ETT) over the ETI. The secondary outcome was the difficulty of intubation. RESULTS: The median total time to ETT placement was significantly shorter with the FTB (37.5 s) compared with the FROVA ETI (63.0 s), P = 0.0006. The median difficulty reported (scores 0–10 with 0 being no difficulty) with the FTB was 2 compared with 5 for the FROVA, P < 0.0001. CONCLUSIONS: The FTB enabled significantly faster and easier placement of the endotracheal tube compared with the FROVA in inexperienced hands intubating a difficult intubation manikin. |
format | Online Article Text |
id | pubmed-7366560 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-73665602020-07-20 A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators Cormack, John Langley, Bridget Bhanabhai, Louisa-Rose Kluger, Roman Int J Emerg Med Original Research BACKGROUND: This unblinded randomised crossover study compares two endotracheal tube introducers (ETIs): the FROVA and the “Flexible Tip Bougie” (FTB), in an airway manikin mimicking difficult intubation with a percentage of glottic opening view of 30%. Participants were Emergency Medicine and Anaesthesia trainees with recent experience of less than twenty patient intubations. The primary outcome was time to intubation, further divided into time taken to pass the ETI and time to railroad the endotracheal tube (ETT) over the ETI. The secondary outcome was the difficulty of intubation. RESULTS: The median total time to ETT placement was significantly shorter with the FTB (37.5 s) compared with the FROVA ETI (63.0 s), P = 0.0006. The median difficulty reported (scores 0–10 with 0 being no difficulty) with the FTB was 2 compared with 5 for the FROVA, P < 0.0001. CONCLUSIONS: The FTB enabled significantly faster and easier placement of the endotracheal tube compared with the FROVA in inexperienced hands intubating a difficult intubation manikin. Springer Berlin Heidelberg 2020-07-17 /pmc/articles/PMC7366560/ /pubmed/32680456 http://dx.doi.org/10.1186/s12245-020-00298-6 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Original Research Cormack, John Langley, Bridget Bhanabhai, Louisa-Rose Kluger, Roman A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators |
title | A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators |
title_full | A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators |
title_fullStr | A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators |
title_full_unstemmed | A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators |
title_short | A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators |
title_sort | randomised crossover comparison of two endotracheal tube introducers: the frova and the flexible tip bougie for glidescope intubation of a difficult airway manikin by infrequent intubators |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7366560/ https://www.ncbi.nlm.nih.gov/pubmed/32680456 http://dx.doi.org/10.1186/s12245-020-00298-6 |
work_keys_str_mv | AT cormackjohn arandomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators AT langleybridget arandomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators AT bhanabhailouisarose arandomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators AT klugerroman arandomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators AT cormackjohn randomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators AT langleybridget randomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators AT bhanabhailouisarose randomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators AT klugerroman randomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators |