Cargando…

A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators

BACKGROUND: This unblinded randomised crossover study compares two endotracheal tube introducers (ETIs): the FROVA and the “Flexible Tip Bougie” (FTB), in an airway manikin mimicking difficult intubation with a percentage of glottic opening view of 30%. Participants were Emergency Medicine and Anaes...

Descripción completa

Detalles Bibliográficos
Autores principales: Cormack, John, Langley, Bridget, Bhanabhai, Louisa-Rose, Kluger, Roman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7366560/
https://www.ncbi.nlm.nih.gov/pubmed/32680456
http://dx.doi.org/10.1186/s12245-020-00298-6
_version_ 1783560243968475136
author Cormack, John
Langley, Bridget
Bhanabhai, Louisa-Rose
Kluger, Roman
author_facet Cormack, John
Langley, Bridget
Bhanabhai, Louisa-Rose
Kluger, Roman
author_sort Cormack, John
collection PubMed
description BACKGROUND: This unblinded randomised crossover study compares two endotracheal tube introducers (ETIs): the FROVA and the “Flexible Tip Bougie” (FTB), in an airway manikin mimicking difficult intubation with a percentage of glottic opening view of 30%. Participants were Emergency Medicine and Anaesthesia trainees with recent experience of less than twenty patient intubations. The primary outcome was time to intubation, further divided into time taken to pass the ETI and time to railroad the endotracheal tube (ETT) over the ETI. The secondary outcome was the difficulty of intubation. RESULTS: The median total time to ETT placement was significantly shorter with the FTB (37.5 s) compared with the FROVA ETI (63.0 s), P = 0.0006. The median difficulty reported (scores 0–10 with 0 being no difficulty) with the FTB was 2 compared with 5 for the FROVA, P < 0.0001. CONCLUSIONS: The FTB enabled significantly faster and easier placement of the endotracheal tube compared with the FROVA in inexperienced hands intubating a difficult intubation manikin.
format Online
Article
Text
id pubmed-7366560
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-73665602020-07-20 A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators Cormack, John Langley, Bridget Bhanabhai, Louisa-Rose Kluger, Roman Int J Emerg Med Original Research BACKGROUND: This unblinded randomised crossover study compares two endotracheal tube introducers (ETIs): the FROVA and the “Flexible Tip Bougie” (FTB), in an airway manikin mimicking difficult intubation with a percentage of glottic opening view of 30%. Participants were Emergency Medicine and Anaesthesia trainees with recent experience of less than twenty patient intubations. The primary outcome was time to intubation, further divided into time taken to pass the ETI and time to railroad the endotracheal tube (ETT) over the ETI. The secondary outcome was the difficulty of intubation. RESULTS: The median total time to ETT placement was significantly shorter with the FTB (37.5 s) compared with the FROVA ETI (63.0 s), P = 0.0006. The median difficulty reported (scores 0–10 with 0 being no difficulty) with the FTB was 2 compared with 5 for the FROVA, P < 0.0001. CONCLUSIONS: The FTB enabled significantly faster and easier placement of the endotracheal tube compared with the FROVA in inexperienced hands intubating a difficult intubation manikin. Springer Berlin Heidelberg 2020-07-17 /pmc/articles/PMC7366560/ /pubmed/32680456 http://dx.doi.org/10.1186/s12245-020-00298-6 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Original Research
Cormack, John
Langley, Bridget
Bhanabhai, Louisa-Rose
Kluger, Roman
A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators
title A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators
title_full A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators
title_fullStr A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators
title_full_unstemmed A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators
title_short A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators
title_sort randomised crossover comparison of two endotracheal tube introducers: the frova and the flexible tip bougie for glidescope intubation of a difficult airway manikin by infrequent intubators
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7366560/
https://www.ncbi.nlm.nih.gov/pubmed/32680456
http://dx.doi.org/10.1186/s12245-020-00298-6
work_keys_str_mv AT cormackjohn arandomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators
AT langleybridget arandomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators
AT bhanabhailouisarose arandomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators
AT klugerroman arandomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators
AT cormackjohn randomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators
AT langleybridget randomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators
AT bhanabhailouisarose randomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators
AT klugerroman randomisedcrossovercomparisonoftwoendotrachealtubeintroducersthefrovaandtheflexibletipbougieforglidescopeintubationofadifficultairwaymanikinbyinfrequentintubators