Evaluating the accuracy of hand models obtained from two 3D scanning techniques

The aim of this study was to identify an efficient approach for 3D imaging of hand. The 3D photographs of hand were taken with Gemini structured-light scanning system (SL scanning) and CT scanning. The 3D photographs, average time of scanning and reconstruction were compared between these two indire...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Fang, Zeng, Lei, Pan, Ding, Sui, Xinlei, Tang, Juyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7367881/
https://www.ncbi.nlm.nih.gov/pubmed/32681038
http://dx.doi.org/10.1038/s41598-020-68457-6
Descripción
Sumario:The aim of this study was to identify an efficient approach for 3D imaging of hand. The 3D photographs of hand were taken with Gemini structured-light scanning system (SL scanning) and CT scanning. The 3D photographs, average time of scanning and reconstruction were compared between these two indirect techniques. The reliability, reproducibility and accuracy were evaluated in these two indirect techniques and the direct measurement (DM). Statistical differences in the measurements were assessed by 99% probability, with clinical significance at > 0.5 mm. The Gemini structured-light scanning system established a complete and smooth 3D hand photograph with shorter scanning and reconstruction time. Reproducibility of CT scanning and SL scanning methods was better (P < 0.01, both) than the DM, but did not differ significantly from each other (P = 0.462). Of the 19 (31.58%) measurements obtained, 6 showed significant differences (P < 0.01). Significant differences were observed more often for circumference dimensions (5/9, 55.56%) than for length dimensions (1/10, 10%). Mean absolute error (AE) of the 10 subjects was very low for 3D CT (0.29 ± 0.10 mm) and SL scanning (0.30 ± 0.11 mm). Absolute percentage error (APE) was 4.69 ± 2.33% and 4.88 ± 2.22% for 3D CT and SL scanning, respectively. AE for the PIP circumference between the 3rd finger (0.58 mm) and 4th finger (0.53 mm) scan was > 0.5 mm, indicating significant difference between DM and CT scanning at the level of 99% probability. In this study, the Gemini structured-light scanning system not only successfully established a complete and smooth 3D hand photograph, but also shortened the scanning and reconstruction time. Compared to the DM, measurements obtained using the two indirect techniques did not show any statistically or clinically insignificant difference in the values of the remaining 17 of 19 measurements (89.47%). Therefore, either of the two alternative techniques could be used instead of the direct measurement method.