Cargando…

Outcomes Following Treatment of Complex Tibial Fractures with Circular External Fixation: A Comparison between the Taylor Spatial Frame and TrueLok-Hex

AIM: The purpose of this study was to compare the functional and radiological outcomes of complex tibia fractures treated with two different hexapod fixators. MATERIAL AND METHODS: This is a retrospective comparative study of patients treated for complex tibial fractures between 2010 and 2015. Inclu...

Descripción completa

Detalles Bibliográficos
Autores principales: Naude, Jaco, Manjra, Muhammad, Birkholtz, Franz F, Barnard, Annette-Christy, Glatt, Vaida, Tetsworth, Kevin, Hohmann, Erik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishers 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7368362/
https://www.ncbi.nlm.nih.gov/pubmed/32742430
http://dx.doi.org/10.5005/jp-journals-10080-1443
_version_ 1783560591898574848
author Naude, Jaco
Manjra, Muhammad
Birkholtz, Franz F
Barnard, Annette-Christy
Glatt, Vaida
Tetsworth, Kevin
Hohmann, Erik
author_facet Naude, Jaco
Manjra, Muhammad
Birkholtz, Franz F
Barnard, Annette-Christy
Glatt, Vaida
Tetsworth, Kevin
Hohmann, Erik
author_sort Naude, Jaco
collection PubMed
description AIM: The purpose of this study was to compare the functional and radiological outcomes of complex tibia fractures treated with two different hexapod fixators. MATERIAL AND METHODS: This is a retrospective comparative study of patients treated for complex tibial fractures between 2010 and 2015. Inclusion criteria was patients between 18 years and 60 years of age, who sustained a complex comminuted open or closed tibial fracture with or without bone loss, who had a minimum of 12 months’ follow-up, and who have been treated definitively using either Taylor Spatial Frame (TSF) or TrueLok-Hexapod System (TL-HEX). The outcome measures were Association for the Study and Application of the Method of Ilizarov (ASAMI) score, foot function index (FFI), EQ5-D, four-step square test (FSST), and timed up and go (TUG) test. Descriptive statistics were used to assess patient demographic information. Categorical variables (ASAMI and EQ5D-5L) were analysed using the χ(2) test. Continuous variables (FFI, functional tests, and radiographic outcomes) were analysed with two-tailed Student’s t tests. RESULTS: In all, 24 patients were treated with the TL-HEX and 21 with the TSF. The mean time for external fixation was 219 ± 107 days (TL-HEX) and 222 ± 98 days (TSF). Union occurred in 92% (TL-HEX) and 100% (TSF). The mean follow-up was 777 ± 278 days (TL-HEX) and 1211 ± 388 days (TSF). Using the ASAMI scores, there were 17 excellent and 6 good results for the TL-HEX and 10 excellent and 11 good results for the TSF (p = 0.33). The FFI was 30 ± 28.7 (TL-HEX) and 26.1+23.9 (TSF) (p = 0.55). The EQ5D was 0.67 ± 0.3 (TL-HEX) and 0.73 ± 0.2 (TSF) (p = 0.43). The mean TUG and FSST were 9.2 ± 3.2 and 10 ± 2.9 seconds (TL-HEX) and 8.4 ± 2.3 and 9.6 ± 3.1 seconds (TSF) (p = 0.34 and 0.69). CONCLUSION: The results of this study suggest that both hexapod external fixation devices have comparable clinical, functional, and radiographic outcomes. Either fixator can be used for the treatment of complex tibial fractures, anticipating good and excellent clinical outcomes in approximately 80% patients. LEVEL OF EVIDENCE: Therapeutic level III HOW TO CITE THIS ARTICLE: Naude J, Manjra M, Birkholtz FF, et al. Outcomes Following Treatment of Complex Tibial Fractures with Circular External Fixation: A Comparison between the Taylor Spatial Frame and TrueLok-Hex. Strategies Trauma Limb Reconstr 2019;14(3):142–147.
format Online
Article
Text
id pubmed-7368362
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Jaypee Brothers Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-73683622020-07-31 Outcomes Following Treatment of Complex Tibial Fractures with Circular External Fixation: A Comparison between the Taylor Spatial Frame and TrueLok-Hex Naude, Jaco Manjra, Muhammad Birkholtz, Franz F Barnard, Annette-Christy Glatt, Vaida Tetsworth, Kevin Hohmann, Erik Strategies Trauma Limb Reconstr Original Article AIM: The purpose of this study was to compare the functional and radiological outcomes of complex tibia fractures treated with two different hexapod fixators. MATERIAL AND METHODS: This is a retrospective comparative study of patients treated for complex tibial fractures between 2010 and 2015. Inclusion criteria was patients between 18 years and 60 years of age, who sustained a complex comminuted open or closed tibial fracture with or without bone loss, who had a minimum of 12 months’ follow-up, and who have been treated definitively using either Taylor Spatial Frame (TSF) or TrueLok-Hexapod System (TL-HEX). The outcome measures were Association for the Study and Application of the Method of Ilizarov (ASAMI) score, foot function index (FFI), EQ5-D, four-step square test (FSST), and timed up and go (TUG) test. Descriptive statistics were used to assess patient demographic information. Categorical variables (ASAMI and EQ5D-5L) were analysed using the χ(2) test. Continuous variables (FFI, functional tests, and radiographic outcomes) were analysed with two-tailed Student’s t tests. RESULTS: In all, 24 patients were treated with the TL-HEX and 21 with the TSF. The mean time for external fixation was 219 ± 107 days (TL-HEX) and 222 ± 98 days (TSF). Union occurred in 92% (TL-HEX) and 100% (TSF). The mean follow-up was 777 ± 278 days (TL-HEX) and 1211 ± 388 days (TSF). Using the ASAMI scores, there were 17 excellent and 6 good results for the TL-HEX and 10 excellent and 11 good results for the TSF (p = 0.33). The FFI was 30 ± 28.7 (TL-HEX) and 26.1+23.9 (TSF) (p = 0.55). The EQ5D was 0.67 ± 0.3 (TL-HEX) and 0.73 ± 0.2 (TSF) (p = 0.43). The mean TUG and FSST were 9.2 ± 3.2 and 10 ± 2.9 seconds (TL-HEX) and 8.4 ± 2.3 and 9.6 ± 3.1 seconds (TSF) (p = 0.34 and 0.69). CONCLUSION: The results of this study suggest that both hexapod external fixation devices have comparable clinical, functional, and radiographic outcomes. Either fixator can be used for the treatment of complex tibial fractures, anticipating good and excellent clinical outcomes in approximately 80% patients. LEVEL OF EVIDENCE: Therapeutic level III HOW TO CITE THIS ARTICLE: Naude J, Manjra M, Birkholtz FF, et al. Outcomes Following Treatment of Complex Tibial Fractures with Circular External Fixation: A Comparison between the Taylor Spatial Frame and TrueLok-Hex. Strategies Trauma Limb Reconstr 2019;14(3):142–147. Jaypee Brothers Medical Publishers 2019 /pmc/articles/PMC7368362/ /pubmed/32742430 http://dx.doi.org/10.5005/jp-journals-10080-1443 Text en Copyright © 2019; Jaypee Brothers Medical Publishers (P) Ltd. © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Original Article
Naude, Jaco
Manjra, Muhammad
Birkholtz, Franz F
Barnard, Annette-Christy
Glatt, Vaida
Tetsworth, Kevin
Hohmann, Erik
Outcomes Following Treatment of Complex Tibial Fractures with Circular External Fixation: A Comparison between the Taylor Spatial Frame and TrueLok-Hex
title Outcomes Following Treatment of Complex Tibial Fractures with Circular External Fixation: A Comparison between the Taylor Spatial Frame and TrueLok-Hex
title_full Outcomes Following Treatment of Complex Tibial Fractures with Circular External Fixation: A Comparison between the Taylor Spatial Frame and TrueLok-Hex
title_fullStr Outcomes Following Treatment of Complex Tibial Fractures with Circular External Fixation: A Comparison between the Taylor Spatial Frame and TrueLok-Hex
title_full_unstemmed Outcomes Following Treatment of Complex Tibial Fractures with Circular External Fixation: A Comparison between the Taylor Spatial Frame and TrueLok-Hex
title_short Outcomes Following Treatment of Complex Tibial Fractures with Circular External Fixation: A Comparison between the Taylor Spatial Frame and TrueLok-Hex
title_sort outcomes following treatment of complex tibial fractures with circular external fixation: a comparison between the taylor spatial frame and truelok-hex
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7368362/
https://www.ncbi.nlm.nih.gov/pubmed/32742430
http://dx.doi.org/10.5005/jp-journals-10080-1443
work_keys_str_mv AT naudejaco outcomesfollowingtreatmentofcomplextibialfractureswithcircularexternalfixationacomparisonbetweenthetaylorspatialframeandtruelokhex
AT manjramuhammad outcomesfollowingtreatmentofcomplextibialfractureswithcircularexternalfixationacomparisonbetweenthetaylorspatialframeandtruelokhex
AT birkholtzfranzf outcomesfollowingtreatmentofcomplextibialfractureswithcircularexternalfixationacomparisonbetweenthetaylorspatialframeandtruelokhex
AT barnardannettechristy outcomesfollowingtreatmentofcomplextibialfractureswithcircularexternalfixationacomparisonbetweenthetaylorspatialframeandtruelokhex
AT glattvaida outcomesfollowingtreatmentofcomplextibialfractureswithcircularexternalfixationacomparisonbetweenthetaylorspatialframeandtruelokhex
AT tetsworthkevin outcomesfollowingtreatmentofcomplextibialfractureswithcircularexternalfixationacomparisonbetweenthetaylorspatialframeandtruelokhex
AT hohmannerik outcomesfollowingtreatmentofcomplextibialfractureswithcircularexternalfixationacomparisonbetweenthetaylorspatialframeandtruelokhex