Cargando…
The effect of knee joint rotation in the sagittal and axial plane on the measurement accuracy of coronal alignment of the lower limb
BACKGROUND: Although the measurement of coronal alignment of the lower limb on conventional full-length weight-bearing anteroposterior (FLWAP) radiographs was reported to be influenced by the knee joint rotation, no comparative analysis was performed considering the effects of knee joint rotation on...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7368736/ https://www.ncbi.nlm.nih.gov/pubmed/32680484 http://dx.doi.org/10.1186/s12891-020-03487-9 |
_version_ | 1783560655438086144 |
---|---|
author | Moon, Hyun-Soo Choi, Chong-Hyuk Jung, Min Lee, Dae-Young Kim, Jung-Hwan Kim, Sung-Hwan |
author_facet | Moon, Hyun-Soo Choi, Chong-Hyuk Jung, Min Lee, Dae-Young Kim, Jung-Hwan Kim, Sung-Hwan |
author_sort | Moon, Hyun-Soo |
collection | PubMed |
description | BACKGROUND: Although the measurement of coronal alignment of the lower limb on conventional full-length weight-bearing anteroposterior (FLWAP) radiographs was reported to be influenced by the knee joint rotation, no comparative analysis was performed considering the effects of knee joint rotation on the sagittal and axial planes simultaneously using the three-dimensional images while taking into account the actual weight-bearing conditions. The aim of this study was to investigate the effect of knee joint rotation on the measurement accuracy of coronal alignment of the lower limb on the FLWAP radiograph. METHODS: Radiographic images of 90 consecutive patients (180 lower limbs) who took both the FLWAP radiograph and the EOS image were retrospectively reviewed. The relationship among delta values of mechanical tibiofemoral angle (mTFA) between the FLWAP radiographs and the EOS images (ΔmTFA), knee flexion/extension angle (sagittal plane rotation) on the EOS images, and patellar rotation (axial plane rotation) on the FLWAP radiographs were analyzed. Further, subgroup analysis according to each direction of knee joint rotation was performed. RESULTS: There was a significant correlation between ΔmTFA and sagittal plane rotation (r = 0.368, P < 0.001), whereas axial plane rotation was not correlated. In the analysis according to the direction, statistically significant correlation was observed only in the knee flexion group (r = 0.399, P < 0.001). The regression analysis showed a significant linear relationship between ΔmTFA and sagittal plane rotation (r(2) = 0.136, P < 0.001). Additional subgroup analysis in patients with the patellar rotation greater than 3% showed a similar result of a linear relationship between ΔmTFA and sagittal plane rotation (r(2) = 0.257, P < 0.001), whereas no statistically significant relationship was found in patients with the patellar rotation less than 3%. CONCLUSION: The measurement accuracy of coronal alignment of the lower limb on the FLWAP radiographs would be influenced by knee flexion, specifically when there is any subtle rotation of the knee joint in the axial plane. A strict patellar forward position without axial plane rotation of the knee could provide accurate results of the measurement even if there is a fixed flexion contracture of the knee. |
format | Online Article Text |
id | pubmed-7368736 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-73687362020-07-20 The effect of knee joint rotation in the sagittal and axial plane on the measurement accuracy of coronal alignment of the lower limb Moon, Hyun-Soo Choi, Chong-Hyuk Jung, Min Lee, Dae-Young Kim, Jung-Hwan Kim, Sung-Hwan BMC Musculoskelet Disord Research Article BACKGROUND: Although the measurement of coronal alignment of the lower limb on conventional full-length weight-bearing anteroposterior (FLWAP) radiographs was reported to be influenced by the knee joint rotation, no comparative analysis was performed considering the effects of knee joint rotation on the sagittal and axial planes simultaneously using the three-dimensional images while taking into account the actual weight-bearing conditions. The aim of this study was to investigate the effect of knee joint rotation on the measurement accuracy of coronal alignment of the lower limb on the FLWAP radiograph. METHODS: Radiographic images of 90 consecutive patients (180 lower limbs) who took both the FLWAP radiograph and the EOS image were retrospectively reviewed. The relationship among delta values of mechanical tibiofemoral angle (mTFA) between the FLWAP radiographs and the EOS images (ΔmTFA), knee flexion/extension angle (sagittal plane rotation) on the EOS images, and patellar rotation (axial plane rotation) on the FLWAP radiographs were analyzed. Further, subgroup analysis according to each direction of knee joint rotation was performed. RESULTS: There was a significant correlation between ΔmTFA and sagittal plane rotation (r = 0.368, P < 0.001), whereas axial plane rotation was not correlated. In the analysis according to the direction, statistically significant correlation was observed only in the knee flexion group (r = 0.399, P < 0.001). The regression analysis showed a significant linear relationship between ΔmTFA and sagittal plane rotation (r(2) = 0.136, P < 0.001). Additional subgroup analysis in patients with the patellar rotation greater than 3% showed a similar result of a linear relationship between ΔmTFA and sagittal plane rotation (r(2) = 0.257, P < 0.001), whereas no statistically significant relationship was found in patients with the patellar rotation less than 3%. CONCLUSION: The measurement accuracy of coronal alignment of the lower limb on the FLWAP radiographs would be influenced by knee flexion, specifically when there is any subtle rotation of the knee joint in the axial plane. A strict patellar forward position without axial plane rotation of the knee could provide accurate results of the measurement even if there is a fixed flexion contracture of the knee. BioMed Central 2020-07-17 /pmc/articles/PMC7368736/ /pubmed/32680484 http://dx.doi.org/10.1186/s12891-020-03487-9 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Moon, Hyun-Soo Choi, Chong-Hyuk Jung, Min Lee, Dae-Young Kim, Jung-Hwan Kim, Sung-Hwan The effect of knee joint rotation in the sagittal and axial plane on the measurement accuracy of coronal alignment of the lower limb |
title | The effect of knee joint rotation in the sagittal and axial plane on the measurement accuracy of coronal alignment of the lower limb |
title_full | The effect of knee joint rotation in the sagittal and axial plane on the measurement accuracy of coronal alignment of the lower limb |
title_fullStr | The effect of knee joint rotation in the sagittal and axial plane on the measurement accuracy of coronal alignment of the lower limb |
title_full_unstemmed | The effect of knee joint rotation in the sagittal and axial plane on the measurement accuracy of coronal alignment of the lower limb |
title_short | The effect of knee joint rotation in the sagittal and axial plane on the measurement accuracy of coronal alignment of the lower limb |
title_sort | effect of knee joint rotation in the sagittal and axial plane on the measurement accuracy of coronal alignment of the lower limb |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7368736/ https://www.ncbi.nlm.nih.gov/pubmed/32680484 http://dx.doi.org/10.1186/s12891-020-03487-9 |
work_keys_str_mv | AT moonhyunsoo theeffectofkneejointrotationinthesagittalandaxialplaneonthemeasurementaccuracyofcoronalalignmentofthelowerlimb AT choichonghyuk theeffectofkneejointrotationinthesagittalandaxialplaneonthemeasurementaccuracyofcoronalalignmentofthelowerlimb AT jungmin theeffectofkneejointrotationinthesagittalandaxialplaneonthemeasurementaccuracyofcoronalalignmentofthelowerlimb AT leedaeyoung theeffectofkneejointrotationinthesagittalandaxialplaneonthemeasurementaccuracyofcoronalalignmentofthelowerlimb AT kimjunghwan theeffectofkneejointrotationinthesagittalandaxialplaneonthemeasurementaccuracyofcoronalalignmentofthelowerlimb AT kimsunghwan theeffectofkneejointrotationinthesagittalandaxialplaneonthemeasurementaccuracyofcoronalalignmentofthelowerlimb AT moonhyunsoo effectofkneejointrotationinthesagittalandaxialplaneonthemeasurementaccuracyofcoronalalignmentofthelowerlimb AT choichonghyuk effectofkneejointrotationinthesagittalandaxialplaneonthemeasurementaccuracyofcoronalalignmentofthelowerlimb AT jungmin effectofkneejointrotationinthesagittalandaxialplaneonthemeasurementaccuracyofcoronalalignmentofthelowerlimb AT leedaeyoung effectofkneejointrotationinthesagittalandaxialplaneonthemeasurementaccuracyofcoronalalignmentofthelowerlimb AT kimjunghwan effectofkneejointrotationinthesagittalandaxialplaneonthemeasurementaccuracyofcoronalalignmentofthelowerlimb AT kimsunghwan effectofkneejointrotationinthesagittalandaxialplaneonthemeasurementaccuracyofcoronalalignmentofthelowerlimb |