Cargando…

Construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root

OBJECTIVE: To evaluate the construction reproducibility of a composite tooth model (CTM) composed of an intraoral-scanned crown and a cone-beam computed tomography (CBCT)-scanned root. METHODS: The study assessed 240 teeth (30 central incisors, 30 canines, 30 second premolars, and 30 first molars in...

Descripción completa

Detalles Bibliográficos
Autores principales: Lim, Seung-Weon, Moon, Ryu-Jin, Kim, Min-Seok, Oh, Min-Hee, Lee, Kyung-Min, Hwang, Hyeon-Shik, Kim, Tae-Woo, Baek, Seung-Hak, Cho, Jin-Hyoung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Association of Orthodontists 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7369385/
https://www.ncbi.nlm.nih.gov/pubmed/32632042
http://dx.doi.org/10.4041/kjod.2020.50.4.229
_version_ 1783560769924759552
author Lim, Seung-Weon
Moon, Ryu-Jin
Kim, Min-Seok
Oh, Min-Hee
Lee, Kyung-Min
Hwang, Hyeon-Shik
Kim, Tae-Woo
Baek, Seung-Hak
Cho, Jin-Hyoung
author_facet Lim, Seung-Weon
Moon, Ryu-Jin
Kim, Min-Seok
Oh, Min-Hee
Lee, Kyung-Min
Hwang, Hyeon-Shik
Kim, Tae-Woo
Baek, Seung-Hak
Cho, Jin-Hyoung
author_sort Lim, Seung-Weon
collection PubMed
description OBJECTIVE: To evaluate the construction reproducibility of a composite tooth model (CTM) composed of an intraoral-scanned crown and a cone-beam computed tomography (CBCT)-scanned root. METHODS: The study assessed 240 teeth (30 central incisors, 30 canines, 30 second premolars, and 30 first molars in the maxillary and mandibular arches) from 15 young adult patients whose pre-treatment intraoral scan and CBCT were available. Examiner-Reference (3 years’ experience in CTM construction) and Examiners-A and Examiner-B (no experience) constructed the individual CTMs independently by performing the following steps: image acquisition and processing into a three-dimensional model, integration of intraoral-scanned crowns and CBCT-scanned teeth, and replacement of the CBCT-scanned crown with the intraoral-scanned crown. The tooth axis angle in terms of mesiodistal angulation and buccolingual inclination of the CTMs constructed by the three examiners were measured. To assess the construction reproducibility of CTMs, intraclass correlation coefficient (ICC) assessments were performed. RESULTS: The ICC values of mesiodistal angulation and buccolingual inclination among the 3 examiners showed excellent agreement (0.950–0.992 and 0.965–0.993; 0.976–0.994 and 0.973–0.995 in the maxillary and mandibular arches, respectively). CONCLUSIONS: The CTM showed excellent construction reproducibility in mesiodistal angulation and buccolingual inclination regardless of the construction skill and experience levels of the examiners.
format Online
Article
Text
id pubmed-7369385
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Korean Association of Orthodontists
record_format MEDLINE/PubMed
spelling pubmed-73693852020-07-29 Construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root Lim, Seung-Weon Moon, Ryu-Jin Kim, Min-Seok Oh, Min-Hee Lee, Kyung-Min Hwang, Hyeon-Shik Kim, Tae-Woo Baek, Seung-Hak Cho, Jin-Hyoung Korean J Orthod Original Article OBJECTIVE: To evaluate the construction reproducibility of a composite tooth model (CTM) composed of an intraoral-scanned crown and a cone-beam computed tomography (CBCT)-scanned root. METHODS: The study assessed 240 teeth (30 central incisors, 30 canines, 30 second premolars, and 30 first molars in the maxillary and mandibular arches) from 15 young adult patients whose pre-treatment intraoral scan and CBCT were available. Examiner-Reference (3 years’ experience in CTM construction) and Examiners-A and Examiner-B (no experience) constructed the individual CTMs independently by performing the following steps: image acquisition and processing into a three-dimensional model, integration of intraoral-scanned crowns and CBCT-scanned teeth, and replacement of the CBCT-scanned crown with the intraoral-scanned crown. The tooth axis angle in terms of mesiodistal angulation and buccolingual inclination of the CTMs constructed by the three examiners were measured. To assess the construction reproducibility of CTMs, intraclass correlation coefficient (ICC) assessments were performed. RESULTS: The ICC values of mesiodistal angulation and buccolingual inclination among the 3 examiners showed excellent agreement (0.950–0.992 and 0.965–0.993; 0.976–0.994 and 0.973–0.995 in the maxillary and mandibular arches, respectively). CONCLUSIONS: The CTM showed excellent construction reproducibility in mesiodistal angulation and buccolingual inclination regardless of the construction skill and experience levels of the examiners. Korean Association of Orthodontists 2020-07-25 2020-07-25 /pmc/articles/PMC7369385/ /pubmed/32632042 http://dx.doi.org/10.4041/kjod.2020.50.4.229 Text en © 2020 The Korean Association of Orthodontists. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lim, Seung-Weon
Moon, Ryu-Jin
Kim, Min-Seok
Oh, Min-Hee
Lee, Kyung-Min
Hwang, Hyeon-Shik
Kim, Tae-Woo
Baek, Seung-Hak
Cho, Jin-Hyoung
Construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root
title Construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root
title_full Construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root
title_fullStr Construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root
title_full_unstemmed Construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root
title_short Construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root
title_sort construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7369385/
https://www.ncbi.nlm.nih.gov/pubmed/32632042
http://dx.doi.org/10.4041/kjod.2020.50.4.229
work_keys_str_mv AT limseungweon constructionreproducibilityofacompositetoothmodelcomposedofanintraoralscannedcrownandaconebeamcomputedtomographyscannedroot
AT moonryujin constructionreproducibilityofacompositetoothmodelcomposedofanintraoralscannedcrownandaconebeamcomputedtomographyscannedroot
AT kimminseok constructionreproducibilityofacompositetoothmodelcomposedofanintraoralscannedcrownandaconebeamcomputedtomographyscannedroot
AT ohminhee constructionreproducibilityofacompositetoothmodelcomposedofanintraoralscannedcrownandaconebeamcomputedtomographyscannedroot
AT leekyungmin constructionreproducibilityofacompositetoothmodelcomposedofanintraoralscannedcrownandaconebeamcomputedtomographyscannedroot
AT hwanghyeonshik constructionreproducibilityofacompositetoothmodelcomposedofanintraoralscannedcrownandaconebeamcomputedtomographyscannedroot
AT kimtaewoo constructionreproducibilityofacompositetoothmodelcomposedofanintraoralscannedcrownandaconebeamcomputedtomographyscannedroot
AT baekseunghak constructionreproducibilityofacompositetoothmodelcomposedofanintraoralscannedcrownandaconebeamcomputedtomographyscannedroot
AT chojinhyoung constructionreproducibilityofacompositetoothmodelcomposedofanintraoralscannedcrownandaconebeamcomputedtomographyscannedroot