Cargando…

Serum periostin reflects dynamic hyperinflation in patients with asthma

INTRODUCTION: Dynamic hyperinflation (DH) is sometimes observed and is associated with impaired daily life activities of asthma. We assessed the relationship between DH and asthma biomarkers (blood eosinophil, fractional exhaled nitric oxide (F(eNO)) and serum periostin) in patients with asthma. MET...

Descripción completa

Detalles Bibliográficos
Autores principales: Asano, Takamitsu, Ohbayashi, Hiroyuki, Ariga, Mitsue, Furuta, Osamu, Kudo, Sahori, Ono, Junya, Izuhara, Kenji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: European Respiratory Society 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7369445/
https://www.ncbi.nlm.nih.gov/pubmed/32714962
http://dx.doi.org/10.1183/23120541.00347-2019
_version_ 1783560783468167168
author Asano, Takamitsu
Ohbayashi, Hiroyuki
Ariga, Mitsue
Furuta, Osamu
Kudo, Sahori
Ono, Junya
Izuhara, Kenji
author_facet Asano, Takamitsu
Ohbayashi, Hiroyuki
Ariga, Mitsue
Furuta, Osamu
Kudo, Sahori
Ono, Junya
Izuhara, Kenji
author_sort Asano, Takamitsu
collection PubMed
description INTRODUCTION: Dynamic hyperinflation (DH) is sometimes observed and is associated with impaired daily life activities of asthma. We assessed the relationship between DH and asthma biomarkers (blood eosinophil, fractional exhaled nitric oxide (F(eNO)) and serum periostin) in patients with asthma. METHODS: Fifty patients with stable asthma were prospectively recruited and underwent blood test, F(eNO) measurement, spirometry and metronome-paced tachypnoea (MPT) test to assess DH. In MPT tests, inspiratory capacity (IC) was measured at baseline and after 30 s of MPT with breathing frequencies of 20, 30 and 40 breaths·min(−1). DH was assessed by the decline of IC from baseline, and maximal IC reduction ≥10% was considered as positive DH. RESULTS: Thirty patients (60%) showed positive DH. Patients with positive DH showed higher serum periostin levels (107.0±30.7 ng·mL(−1)) than patients with negative DH (89.7±23.7) (p=0.04). Patients in Global Initiative for Asthma treatment steps 4–5 (n=19) showed higher serum periostin levels (p=0.01) and more severe IC reduction after MPT (p<0.0001) than patients in steps 1–3 (n=31). Maximal IC reduction after MPT was significantly correlated with asthma control test score (r=−0.28, p=0.05), forced expiratory volume in 1 s (r=−0.56, p<0.0001), and serum periostin levels (r=0.41, p=0.003). CONCLUSION: Serum periostin may have the possibility to reflect DH in patients with stable asthma.
format Online
Article
Text
id pubmed-7369445
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher European Respiratory Society
record_format MEDLINE/PubMed
spelling pubmed-73694452020-07-23 Serum periostin reflects dynamic hyperinflation in patients with asthma Asano, Takamitsu Ohbayashi, Hiroyuki Ariga, Mitsue Furuta, Osamu Kudo, Sahori Ono, Junya Izuhara, Kenji ERJ Open Res Original Articles INTRODUCTION: Dynamic hyperinflation (DH) is sometimes observed and is associated with impaired daily life activities of asthma. We assessed the relationship between DH and asthma biomarkers (blood eosinophil, fractional exhaled nitric oxide (F(eNO)) and serum periostin) in patients with asthma. METHODS: Fifty patients with stable asthma were prospectively recruited and underwent blood test, F(eNO) measurement, spirometry and metronome-paced tachypnoea (MPT) test to assess DH. In MPT tests, inspiratory capacity (IC) was measured at baseline and after 30 s of MPT with breathing frequencies of 20, 30 and 40 breaths·min(−1). DH was assessed by the decline of IC from baseline, and maximal IC reduction ≥10% was considered as positive DH. RESULTS: Thirty patients (60%) showed positive DH. Patients with positive DH showed higher serum periostin levels (107.0±30.7 ng·mL(−1)) than patients with negative DH (89.7±23.7) (p=0.04). Patients in Global Initiative for Asthma treatment steps 4–5 (n=19) showed higher serum periostin levels (p=0.01) and more severe IC reduction after MPT (p<0.0001) than patients in steps 1–3 (n=31). Maximal IC reduction after MPT was significantly correlated with asthma control test score (r=−0.28, p=0.05), forced expiratory volume in 1 s (r=−0.56, p<0.0001), and serum periostin levels (r=0.41, p=0.003). CONCLUSION: Serum periostin may have the possibility to reflect DH in patients with stable asthma. European Respiratory Society 2020-07-20 /pmc/articles/PMC7369445/ /pubmed/32714962 http://dx.doi.org/10.1183/23120541.00347-2019 Text en Copyright ©ERS 2020 http://creativecommons.org/licenses/by-nc/4.0/This article is open access and distributed under the terms of the Creative Commons Attribution Non-Commercial Licence 4.0.
spellingShingle Original Articles
Asano, Takamitsu
Ohbayashi, Hiroyuki
Ariga, Mitsue
Furuta, Osamu
Kudo, Sahori
Ono, Junya
Izuhara, Kenji
Serum periostin reflects dynamic hyperinflation in patients with asthma
title Serum periostin reflects dynamic hyperinflation in patients with asthma
title_full Serum periostin reflects dynamic hyperinflation in patients with asthma
title_fullStr Serum periostin reflects dynamic hyperinflation in patients with asthma
title_full_unstemmed Serum periostin reflects dynamic hyperinflation in patients with asthma
title_short Serum periostin reflects dynamic hyperinflation in patients with asthma
title_sort serum periostin reflects dynamic hyperinflation in patients with asthma
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7369445/
https://www.ncbi.nlm.nih.gov/pubmed/32714962
http://dx.doi.org/10.1183/23120541.00347-2019
work_keys_str_mv AT asanotakamitsu serumperiostinreflectsdynamichyperinflationinpatientswithasthma
AT ohbayashihiroyuki serumperiostinreflectsdynamichyperinflationinpatientswithasthma
AT arigamitsue serumperiostinreflectsdynamichyperinflationinpatientswithasthma
AT furutaosamu serumperiostinreflectsdynamichyperinflationinpatientswithasthma
AT kudosahori serumperiostinreflectsdynamichyperinflationinpatientswithasthma
AT onojunya serumperiostinreflectsdynamichyperinflationinpatientswithasthma
AT izuharakenji serumperiostinreflectsdynamichyperinflationinpatientswithasthma