Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany

This study investigates the effect of anthropogenic heat emissions from air conditioning systems (AC) on air temperature and AC energy consumption in Berlin, Germany. We conduct simulations applying the model system CCLM/DCEP-BEM, a coupled system of the mesoscale climate model COSMO-CLM (CCLM) and...

Descripción completa

Detalles Bibliográficos
Autores principales: Jin, Luxi, Schubert, Sebastian, Hefny Salim, Mohamed, Schneider, Christoph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7369797/
https://www.ncbi.nlm.nih.gov/pubmed/32605212
http://dx.doi.org/10.3390/ijerph17134645
_version_ 1783560851425329152
author Jin, Luxi
Schubert, Sebastian
Hefny Salim, Mohamed
Schneider, Christoph
author_facet Jin, Luxi
Schubert, Sebastian
Hefny Salim, Mohamed
Schneider, Christoph
author_sort Jin, Luxi
collection PubMed
description This study investigates the effect of anthropogenic heat emissions from air conditioning systems (AC) on air temperature and AC energy consumption in Berlin, Germany. We conduct simulations applying the model system CCLM/DCEP-BEM, a coupled system of the mesoscale climate model COSMO-CLM (CCLM) and the urban Double Canyon Effect Parameterization scheme with a building energy model (DCEP-BEM), for a summer period of 2018. The DCEP-BEM model is designed to explicitly compute the anthropogenic heat emissions from urban buildings and the heat flux transfer between buildings and the atmosphere. We investigate two locations where the AC outdoor units are installed: either on the wall of a building (VerAC) or on the rooftop of a building (HorAC). AC waste heat emissions considerably increase the near-surface air temperature. Compared to a reference scenario without AC systems, the VerAC scenario with a target indoor temperature of 22 [Formula: see text] results in a temperature increase of up to [Formula: see text] [Formula: see text]. The increase is more pronounced during the night and for urban areas. The effect of HorAC on air temperature is overall smaller than in VerAC. With the target indoor temperature of 22 [Formula: see text] , an urban site’s daily average AC energy consumption per floor area of a room is [Formula: see text] [Formula: see text] , which is 35% more than that of a suburban site. This energy-saving results from the urban heat island effect and different building parameters between both sits. The maximum AC energy consumption occurs in the afternoon. When the target indoor temperature rises, the AC energy consumption decreases at a rate of about 16% per 2 [Formula: see text] change in indoor temperature. The nighttime near-surface temperature in VerAC scenarios shows a declining trend ([Formula: see text] [Formula: see text] per 2 [Formula: see text] change) with increasing target indoor temperature. This feature is not obvious in HorAC scenarios which further confirms that HorAC has a smaller impact on near-surface air temperature.
format Online
Article
Text
id pubmed-7369797
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73697972020-07-21 Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany Jin, Luxi Schubert, Sebastian Hefny Salim, Mohamed Schneider, Christoph Int J Environ Res Public Health Article This study investigates the effect of anthropogenic heat emissions from air conditioning systems (AC) on air temperature and AC energy consumption in Berlin, Germany. We conduct simulations applying the model system CCLM/DCEP-BEM, a coupled system of the mesoscale climate model COSMO-CLM (CCLM) and the urban Double Canyon Effect Parameterization scheme with a building energy model (DCEP-BEM), for a summer period of 2018. The DCEP-BEM model is designed to explicitly compute the anthropogenic heat emissions from urban buildings and the heat flux transfer between buildings and the atmosphere. We investigate two locations where the AC outdoor units are installed: either on the wall of a building (VerAC) or on the rooftop of a building (HorAC). AC waste heat emissions considerably increase the near-surface air temperature. Compared to a reference scenario without AC systems, the VerAC scenario with a target indoor temperature of 22 [Formula: see text] results in a temperature increase of up to [Formula: see text] [Formula: see text]. The increase is more pronounced during the night and for urban areas. The effect of HorAC on air temperature is overall smaller than in VerAC. With the target indoor temperature of 22 [Formula: see text] , an urban site’s daily average AC energy consumption per floor area of a room is [Formula: see text] [Formula: see text] , which is 35% more than that of a suburban site. This energy-saving results from the urban heat island effect and different building parameters between both sits. The maximum AC energy consumption occurs in the afternoon. When the target indoor temperature rises, the AC energy consumption decreases at a rate of about 16% per 2 [Formula: see text] change in indoor temperature. The nighttime near-surface temperature in VerAC scenarios shows a declining trend ([Formula: see text] [Formula: see text] per 2 [Formula: see text] change) with increasing target indoor temperature. This feature is not obvious in HorAC scenarios which further confirms that HorAC has a smaller impact on near-surface air temperature. MDPI 2020-06-28 2020-07 /pmc/articles/PMC7369797/ /pubmed/32605212 http://dx.doi.org/10.3390/ijerph17134645 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jin, Luxi
Schubert, Sebastian
Hefny Salim, Mohamed
Schneider, Christoph
Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany
title Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany
title_full Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany
title_fullStr Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany
title_full_unstemmed Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany
title_short Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany
title_sort impact of air conditioning systems on the outdoor thermal environment during summer in berlin, germany
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7369797/
https://www.ncbi.nlm.nih.gov/pubmed/32605212
http://dx.doi.org/10.3390/ijerph17134645
work_keys_str_mv AT jinluxi impactofairconditioningsystemsontheoutdoorthermalenvironmentduringsummerinberlingermany
AT schubertsebastian impactofairconditioningsystemsontheoutdoorthermalenvironmentduringsummerinberlingermany
AT hefnysalimmohamed impactofairconditioningsystemsontheoutdoorthermalenvironmentduringsummerinberlingermany
AT schneiderchristoph impactofairconditioningsystemsontheoutdoorthermalenvironmentduringsummerinberlingermany