Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany
This study investigates the effect of anthropogenic heat emissions from air conditioning systems (AC) on air temperature and AC energy consumption in Berlin, Germany. We conduct simulations applying the model system CCLM/DCEP-BEM, a coupled system of the mesoscale climate model COSMO-CLM (CCLM) and...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7369797/ https://www.ncbi.nlm.nih.gov/pubmed/32605212 http://dx.doi.org/10.3390/ijerph17134645 |
_version_ | 1783560851425329152 |
---|---|
author | Jin, Luxi Schubert, Sebastian Hefny Salim, Mohamed Schneider, Christoph |
author_facet | Jin, Luxi Schubert, Sebastian Hefny Salim, Mohamed Schneider, Christoph |
author_sort | Jin, Luxi |
collection | PubMed |
description | This study investigates the effect of anthropogenic heat emissions from air conditioning systems (AC) on air temperature and AC energy consumption in Berlin, Germany. We conduct simulations applying the model system CCLM/DCEP-BEM, a coupled system of the mesoscale climate model COSMO-CLM (CCLM) and the urban Double Canyon Effect Parameterization scheme with a building energy model (DCEP-BEM), for a summer period of 2018. The DCEP-BEM model is designed to explicitly compute the anthropogenic heat emissions from urban buildings and the heat flux transfer between buildings and the atmosphere. We investigate two locations where the AC outdoor units are installed: either on the wall of a building (VerAC) or on the rooftop of a building (HorAC). AC waste heat emissions considerably increase the near-surface air temperature. Compared to a reference scenario without AC systems, the VerAC scenario with a target indoor temperature of 22 [Formula: see text] results in a temperature increase of up to [Formula: see text] [Formula: see text]. The increase is more pronounced during the night and for urban areas. The effect of HorAC on air temperature is overall smaller than in VerAC. With the target indoor temperature of 22 [Formula: see text] , an urban site’s daily average AC energy consumption per floor area of a room is [Formula: see text] [Formula: see text] , which is 35% more than that of a suburban site. This energy-saving results from the urban heat island effect and different building parameters between both sits. The maximum AC energy consumption occurs in the afternoon. When the target indoor temperature rises, the AC energy consumption decreases at a rate of about 16% per 2 [Formula: see text] change in indoor temperature. The nighttime near-surface temperature in VerAC scenarios shows a declining trend ([Formula: see text] [Formula: see text] per 2 [Formula: see text] change) with increasing target indoor temperature. This feature is not obvious in HorAC scenarios which further confirms that HorAC has a smaller impact on near-surface air temperature. |
format | Online Article Text |
id | pubmed-7369797 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-73697972020-07-21 Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany Jin, Luxi Schubert, Sebastian Hefny Salim, Mohamed Schneider, Christoph Int J Environ Res Public Health Article This study investigates the effect of anthropogenic heat emissions from air conditioning systems (AC) on air temperature and AC energy consumption in Berlin, Germany. We conduct simulations applying the model system CCLM/DCEP-BEM, a coupled system of the mesoscale climate model COSMO-CLM (CCLM) and the urban Double Canyon Effect Parameterization scheme with a building energy model (DCEP-BEM), for a summer period of 2018. The DCEP-BEM model is designed to explicitly compute the anthropogenic heat emissions from urban buildings and the heat flux transfer between buildings and the atmosphere. We investigate two locations where the AC outdoor units are installed: either on the wall of a building (VerAC) or on the rooftop of a building (HorAC). AC waste heat emissions considerably increase the near-surface air temperature. Compared to a reference scenario without AC systems, the VerAC scenario with a target indoor temperature of 22 [Formula: see text] results in a temperature increase of up to [Formula: see text] [Formula: see text]. The increase is more pronounced during the night and for urban areas. The effect of HorAC on air temperature is overall smaller than in VerAC. With the target indoor temperature of 22 [Formula: see text] , an urban site’s daily average AC energy consumption per floor area of a room is [Formula: see text] [Formula: see text] , which is 35% more than that of a suburban site. This energy-saving results from the urban heat island effect and different building parameters between both sits. The maximum AC energy consumption occurs in the afternoon. When the target indoor temperature rises, the AC energy consumption decreases at a rate of about 16% per 2 [Formula: see text] change in indoor temperature. The nighttime near-surface temperature in VerAC scenarios shows a declining trend ([Formula: see text] [Formula: see text] per 2 [Formula: see text] change) with increasing target indoor temperature. This feature is not obvious in HorAC scenarios which further confirms that HorAC has a smaller impact on near-surface air temperature. MDPI 2020-06-28 2020-07 /pmc/articles/PMC7369797/ /pubmed/32605212 http://dx.doi.org/10.3390/ijerph17134645 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jin, Luxi Schubert, Sebastian Hefny Salim, Mohamed Schneider, Christoph Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany |
title | Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany |
title_full | Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany |
title_fullStr | Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany |
title_full_unstemmed | Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany |
title_short | Impact of Air Conditioning Systems on the Outdoor Thermal Environment during Summer in Berlin, Germany |
title_sort | impact of air conditioning systems on the outdoor thermal environment during summer in berlin, germany |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7369797/ https://www.ncbi.nlm.nih.gov/pubmed/32605212 http://dx.doi.org/10.3390/ijerph17134645 |
work_keys_str_mv | AT jinluxi impactofairconditioningsystemsontheoutdoorthermalenvironmentduringsummerinberlingermany AT schubertsebastian impactofairconditioningsystemsontheoutdoorthermalenvironmentduringsummerinberlingermany AT hefnysalimmohamed impactofairconditioningsystemsontheoutdoorthermalenvironmentduringsummerinberlingermany AT schneiderchristoph impactofairconditioningsystemsontheoutdoorthermalenvironmentduringsummerinberlingermany |