Effect of Different Implant Designs on Strain and Stress Distribution under Non-Axial Loading: A Three-Dimensional Finite Element Analysis
Implant design evolved alongside the development of implant therapy. The purpose of this finite element analysis (FEA) study was to analyze the influence of different implant designs on the stress and strain distribution to the implants and surrounding bone. Three implant designs with the same lengt...
Autores principales: | Oliveira, Hélder, Brizuela Velasco, Aritza, Ríos-Santos, José-Vicente, Sánchez Lasheras, Fernando, Lemos, Bernardo Ferreira, Gil, Francisco Javier, Carvalho, Alexandrine, Herrero-Climent, Mariano |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7370002/ https://www.ncbi.nlm.nih.gov/pubmed/32630294 http://dx.doi.org/10.3390/ijerph17134738 |
Ejemplares similares
-
A Biomechanical Analysis of the Influence of the Morfology of the Bone Blocks Grafts on the Transfer of Tension or Load to the Soft Tissue by Means of the Finite Elements Method
por: Gil-Marques, Blanca, et al.
Publicado: (2022) -
Corrosion Behavior of Titanium Dental Implants with Implantoplasty
por: Lozano, Pablo, et al.
Publicado: (2022) -
Relevant Aspects of the Dental Implant Design on the Insertion Torque, Resonance Frequency Analysis (RFA) and Micromobility: An In Vitro Study
por: Herrero-Climent, Mariano, et al.
Publicado: (2023) -
Differences between the Fittings of Dental Prostheses Produced by CAD-CAM and Laser Sintering Processes
por: Herrero-Climent, Mariano, et al.
Publicado: (2023) -
Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study
por: Romero, Marta, et al.
Publicado: (2023)