Cargando…

Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandibular Condyle. A Comparative Study Using a Surface-to-Surface Matching Technique

The aim of this study was to assess the accuracy of 3D rendering of the mandibular condylar region obtained from different semi-automatic segmentation methodology. A total of 10 Cone beam computed tomography (CBCT) were selected to perform semi-automatic segmentation of the condyles by using three f...

Descripción completa

Detalles Bibliográficos
Autores principales: Lo Giudice, Antonino, Quinzi, Vincenzo, Ronsivalle, Vincenzo, Farronato, Marco, Nicotra, Carmelo, Indelicato, Francesco, Isola, Gaetano
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7370104/
https://www.ncbi.nlm.nih.gov/pubmed/32635238
http://dx.doi.org/10.3390/ijerph17134789
_version_ 1783560923719401472
author Lo Giudice, Antonino
Quinzi, Vincenzo
Ronsivalle, Vincenzo
Farronato, Marco
Nicotra, Carmelo
Indelicato, Francesco
Isola, Gaetano
author_facet Lo Giudice, Antonino
Quinzi, Vincenzo
Ronsivalle, Vincenzo
Farronato, Marco
Nicotra, Carmelo
Indelicato, Francesco
Isola, Gaetano
author_sort Lo Giudice, Antonino
collection PubMed
description The aim of this study was to assess the accuracy of 3D rendering of the mandibular condylar region obtained from different semi-automatic segmentation methodology. A total of 10 Cone beam computed tomography (CBCT) were selected to perform semi-automatic segmentation of the condyles by using three free-source software (Invesalius, version 3.0.0, Centro de Tecnologia da Informação Renato Archer, Campinas, SP, Brazil; ITK-Snap, version2.2.0; Slicer 3D, version 4.10.2) and one commercially available software Dolphin 3D (Dolphin Imaging, version 11.0, Chatsworth, CA, USA). The same models were also manually segmented (Mimics, version 17.01, Materialise, Leuven, Belgium) and set as ground truth. The accuracy of semi-automatic segmentation was evaluated by (1) comparing the volume of each semi-automatic 3D rendered condylar model with that obtained with manual segmentation, (2) deviation analysis of each 3D rendered mandibular models with those obtained from manual segmentation. No significant differences were found in the volumetric dimensions of the condylar models among the tested software (p > 0.05). However, the color-coded map showed underestimation of the condylar models obtained with ITK-Snap and Slicer 3D, and overestimation with Dolphin 3D and Invesalius. Excellent reliability was found for both intra-observer and inter-observer readings. Despite the excellent reliability, the present findings suggest that data of condylar morphology obtained with semi-automatic segmentation should be taken with caution when an accurate definition of condylar boundaries is required.
format Online
Article
Text
id pubmed-7370104
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73701042020-07-21 Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandibular Condyle. A Comparative Study Using a Surface-to-Surface Matching Technique Lo Giudice, Antonino Quinzi, Vincenzo Ronsivalle, Vincenzo Farronato, Marco Nicotra, Carmelo Indelicato, Francesco Isola, Gaetano Int J Environ Res Public Health Article The aim of this study was to assess the accuracy of 3D rendering of the mandibular condylar region obtained from different semi-automatic segmentation methodology. A total of 10 Cone beam computed tomography (CBCT) were selected to perform semi-automatic segmentation of the condyles by using three free-source software (Invesalius, version 3.0.0, Centro de Tecnologia da Informação Renato Archer, Campinas, SP, Brazil; ITK-Snap, version2.2.0; Slicer 3D, version 4.10.2) and one commercially available software Dolphin 3D (Dolphin Imaging, version 11.0, Chatsworth, CA, USA). The same models were also manually segmented (Mimics, version 17.01, Materialise, Leuven, Belgium) and set as ground truth. The accuracy of semi-automatic segmentation was evaluated by (1) comparing the volume of each semi-automatic 3D rendered condylar model with that obtained with manual segmentation, (2) deviation analysis of each 3D rendered mandibular models with those obtained from manual segmentation. No significant differences were found in the volumetric dimensions of the condylar models among the tested software (p > 0.05). However, the color-coded map showed underestimation of the condylar models obtained with ITK-Snap and Slicer 3D, and overestimation with Dolphin 3D and Invesalius. Excellent reliability was found for both intra-observer and inter-observer readings. Despite the excellent reliability, the present findings suggest that data of condylar morphology obtained with semi-automatic segmentation should be taken with caution when an accurate definition of condylar boundaries is required. MDPI 2020-07-03 2020-07 /pmc/articles/PMC7370104/ /pubmed/32635238 http://dx.doi.org/10.3390/ijerph17134789 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lo Giudice, Antonino
Quinzi, Vincenzo
Ronsivalle, Vincenzo
Farronato, Marco
Nicotra, Carmelo
Indelicato, Francesco
Isola, Gaetano
Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandibular Condyle. A Comparative Study Using a Surface-to-Surface Matching Technique
title Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandibular Condyle. A Comparative Study Using a Surface-to-Surface Matching Technique
title_full Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandibular Condyle. A Comparative Study Using a Surface-to-Surface Matching Technique
title_fullStr Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandibular Condyle. A Comparative Study Using a Surface-to-Surface Matching Technique
title_full_unstemmed Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandibular Condyle. A Comparative Study Using a Surface-to-Surface Matching Technique
title_short Evaluation of Imaging Software Accuracy for 3-Dimensional Analysis of the Mandibular Condyle. A Comparative Study Using a Surface-to-Surface Matching Technique
title_sort evaluation of imaging software accuracy for 3-dimensional analysis of the mandibular condyle. a comparative study using a surface-to-surface matching technique
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7370104/
https://www.ncbi.nlm.nih.gov/pubmed/32635238
http://dx.doi.org/10.3390/ijerph17134789
work_keys_str_mv AT logiudiceantonino evaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibularcondyleacomparativestudyusingasurfacetosurfacematchingtechnique
AT quinzivincenzo evaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibularcondyleacomparativestudyusingasurfacetosurfacematchingtechnique
AT ronsivallevincenzo evaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibularcondyleacomparativestudyusingasurfacetosurfacematchingtechnique
AT farronatomarco evaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibularcondyleacomparativestudyusingasurfacetosurfacematchingtechnique
AT nicotracarmelo evaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibularcondyleacomparativestudyusingasurfacetosurfacematchingtechnique
AT indelicatofrancesco evaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibularcondyleacomparativestudyusingasurfacetosurfacematchingtechnique
AT isolagaetano evaluationofimagingsoftwareaccuracyfor3dimensionalanalysisofthemandibularcondyleacomparativestudyusingasurfacetosurfacematchingtechnique