Performance Analysis of PCM Ceiling Coupling with Earth-Air Heat Exchanger for Building Cooling

In recent years, the systematic application of phase change materials (PCM) is continuously developing. In this paper, an innovative PCM ceiling coupled with earth-air heat exchanger (EAHE) cooling system was proposed for building cooling. The system aimed to combine the cooling capacity of soil and...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, Shilei, Liang, Bin, Li, Xinhua, Kong, Xiangfei, Jia, Wei, Wang, Lu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7372354/
https://www.ncbi.nlm.nih.gov/pubmed/32605066
http://dx.doi.org/10.3390/ma13132890
_version_ 1783561297113120768
author Lu, Shilei
Liang, Bin
Li, Xinhua
Kong, Xiangfei
Jia, Wei
Wang, Lu
author_facet Lu, Shilei
Liang, Bin
Li, Xinhua
Kong, Xiangfei
Jia, Wei
Wang, Lu
author_sort Lu, Shilei
collection PubMed
description In recent years, the systematic application of phase change materials (PCM) is continuously developing. In this paper, an innovative PCM ceiling coupled with earth-air heat exchanger (EAHE) cooling system was proposed for building cooling. The system aimed to combine the cooling capacity of soil and the energy storage capacity of PCM, thus improving the indoor thermal environment. Performance of the system was tested by experimental method while data analysis focused on the indoor side. To research the effect of cold storage time on the performance of the system, two different operation strategies were adopted for comparison: 8-h cold storage strategy and 12-h cold storage strategy. Moreover, a control group was set up to observe the performance of the system on indoor temperature under the same weather conditions. The result showed that the experimental room in which we installed this system could reduce peak temperature by 2.1 °C under 8-h timed cold storage strategy and 2.7 °C under 12-h timed cold storage strategy. What is more, under the two operation strategies, temperature and heat flux of the PCM ceiling had similar distribution characteristics. Different strategies mainly affected the sustainability of the system and phase transition efficiency of the PCM ceiling.
format Online
Article
Text
id pubmed-7372354
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73723542020-08-05 Performance Analysis of PCM Ceiling Coupling with Earth-Air Heat Exchanger for Building Cooling Lu, Shilei Liang, Bin Li, Xinhua Kong, Xiangfei Jia, Wei Wang, Lu Materials (Basel) Article In recent years, the systematic application of phase change materials (PCM) is continuously developing. In this paper, an innovative PCM ceiling coupled with earth-air heat exchanger (EAHE) cooling system was proposed for building cooling. The system aimed to combine the cooling capacity of soil and the energy storage capacity of PCM, thus improving the indoor thermal environment. Performance of the system was tested by experimental method while data analysis focused on the indoor side. To research the effect of cold storage time on the performance of the system, two different operation strategies were adopted for comparison: 8-h cold storage strategy and 12-h cold storage strategy. Moreover, a control group was set up to observe the performance of the system on indoor temperature under the same weather conditions. The result showed that the experimental room in which we installed this system could reduce peak temperature by 2.1 °C under 8-h timed cold storage strategy and 2.7 °C under 12-h timed cold storage strategy. What is more, under the two operation strategies, temperature and heat flux of the PCM ceiling had similar distribution characteristics. Different strategies mainly affected the sustainability of the system and phase transition efficiency of the PCM ceiling. MDPI 2020-06-27 /pmc/articles/PMC7372354/ /pubmed/32605066 http://dx.doi.org/10.3390/ma13132890 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lu, Shilei
Liang, Bin
Li, Xinhua
Kong, Xiangfei
Jia, Wei
Wang, Lu
Performance Analysis of PCM Ceiling Coupling with Earth-Air Heat Exchanger for Building Cooling
title Performance Analysis of PCM Ceiling Coupling with Earth-Air Heat Exchanger for Building Cooling
title_full Performance Analysis of PCM Ceiling Coupling with Earth-Air Heat Exchanger for Building Cooling
title_fullStr Performance Analysis of PCM Ceiling Coupling with Earth-Air Heat Exchanger for Building Cooling
title_full_unstemmed Performance Analysis of PCM Ceiling Coupling with Earth-Air Heat Exchanger for Building Cooling
title_short Performance Analysis of PCM Ceiling Coupling with Earth-Air Heat Exchanger for Building Cooling
title_sort performance analysis of pcm ceiling coupling with earth-air heat exchanger for building cooling
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7372354/
https://www.ncbi.nlm.nih.gov/pubmed/32605066
http://dx.doi.org/10.3390/ma13132890
work_keys_str_mv AT lushilei performanceanalysisofpcmceilingcouplingwithearthairheatexchangerforbuildingcooling
AT liangbin performanceanalysisofpcmceilingcouplingwithearthairheatexchangerforbuildingcooling
AT lixinhua performanceanalysisofpcmceilingcouplingwithearthairheatexchangerforbuildingcooling
AT kongxiangfei performanceanalysisofpcmceilingcouplingwithearthairheatexchangerforbuildingcooling
AT jiawei performanceanalysisofpcmceilingcouplingwithearthairheatexchangerforbuildingcooling
AT wanglu performanceanalysisofpcmceilingcouplingwithearthairheatexchangerforbuildingcooling