Cargando…

Calibration of Steel Rings for the Measurement of Strain and Shrinkage Stress for Cement-Based Composites

Concrete shrinkage is a phenomenon that results in a decrease of volume in the composite material during the curing period. The method for determining the effects of restrained shrinkage is described in Standard ASTM C 1581/C 1581M–09a. This article shows the calibration of measuring rings with resp...

Descripción completa

Detalles Bibliográficos
Autores principales: Zieliński, Adam, Kaszyńska, Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7372365/
https://www.ncbi.nlm.nih.gov/pubmed/32630742
http://dx.doi.org/10.3390/ma13132963
_version_ 1783561299699957760
author Zieliński, Adam
Kaszyńska, Maria
author_facet Zieliński, Adam
Kaszyńska, Maria
author_sort Zieliński, Adam
collection PubMed
description Concrete shrinkage is a phenomenon that results in a decrease of volume in the composite material during the curing period. The method for determining the effects of restrained shrinkage is described in Standard ASTM C 1581/C 1581M–09a. This article shows the calibration of measuring rings with respect to the theory of elasticity and the analysis of the relationship of steel ring deformation to high-performance concrete tensile stress as a function of time. Steel rings equipped with strain gauges are used for measurement of the strain during the compression of the samples. The strain is caused by the shrinkage of the concrete ring specimen that tightens around steel rings. The method allows registering the changes to the shrinkage process in time and evaluating the susceptibility of concrete to cracking. However, the standard does not focus on the details of the mechanical design of the test bench. To acquire accurate measurements, the test bench needs to be calibrated. Measurement errors may be caused by an improper, uneven installation of strain gauges, imprecise geometry of the steel measuring rings, or incorrect equipment settings. The calibration method makes it possible to determine the stress in a concrete sample leading to its cracking at specific deformation of the steel ring.
format Online
Article
Text
id pubmed-7372365
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73723652020-08-05 Calibration of Steel Rings for the Measurement of Strain and Shrinkage Stress for Cement-Based Composites Zieliński, Adam Kaszyńska, Maria Materials (Basel) Article Concrete shrinkage is a phenomenon that results in a decrease of volume in the composite material during the curing period. The method for determining the effects of restrained shrinkage is described in Standard ASTM C 1581/C 1581M–09a. This article shows the calibration of measuring rings with respect to the theory of elasticity and the analysis of the relationship of steel ring deformation to high-performance concrete tensile stress as a function of time. Steel rings equipped with strain gauges are used for measurement of the strain during the compression of the samples. The strain is caused by the shrinkage of the concrete ring specimen that tightens around steel rings. The method allows registering the changes to the shrinkage process in time and evaluating the susceptibility of concrete to cracking. However, the standard does not focus on the details of the mechanical design of the test bench. To acquire accurate measurements, the test bench needs to be calibrated. Measurement errors may be caused by an improper, uneven installation of strain gauges, imprecise geometry of the steel measuring rings, or incorrect equipment settings. The calibration method makes it possible to determine the stress in a concrete sample leading to its cracking at specific deformation of the steel ring. MDPI 2020-07-02 /pmc/articles/PMC7372365/ /pubmed/32630742 http://dx.doi.org/10.3390/ma13132963 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zieliński, Adam
Kaszyńska, Maria
Calibration of Steel Rings for the Measurement of Strain and Shrinkage Stress for Cement-Based Composites
title Calibration of Steel Rings for the Measurement of Strain and Shrinkage Stress for Cement-Based Composites
title_full Calibration of Steel Rings for the Measurement of Strain and Shrinkage Stress for Cement-Based Composites
title_fullStr Calibration of Steel Rings for the Measurement of Strain and Shrinkage Stress for Cement-Based Composites
title_full_unstemmed Calibration of Steel Rings for the Measurement of Strain and Shrinkage Stress for Cement-Based Composites
title_short Calibration of Steel Rings for the Measurement of Strain and Shrinkage Stress for Cement-Based Composites
title_sort calibration of steel rings for the measurement of strain and shrinkage stress for cement-based composites
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7372365/
https://www.ncbi.nlm.nih.gov/pubmed/32630742
http://dx.doi.org/10.3390/ma13132963
work_keys_str_mv AT zielinskiadam calibrationofsteelringsforthemeasurementofstrainandshrinkagestressforcementbasedcomposites
AT kaszynskamaria calibrationofsteelringsforthemeasurementofstrainandshrinkagestressforcementbasedcomposites