Cargando…
Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study
BACKGROUND: To investigate in the conventional techniques of the pedicle screws using triggered screw electromyography (t-EMG), considering different threshold cutoffs: 10, 15, 20 25 mA, for predicting pedicle screw positioning during surgery of the adolescent with idiopathic scoliosis (AIS). METHOD...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7372782/ https://www.ncbi.nlm.nih.gov/pubmed/32689992 http://dx.doi.org/10.1186/s12891-020-03491-z |
_version_ | 1783561380815699968 |
---|---|
author | Barsotti, Carlos Eduardo Gavassi, Bruno Moreira Prado, Francisco Eugenio Batista, Bernardo Nogueira de Resende Pratali, Raphael Ribeiro, Ana Paula de Oliveira, Carlos Eduardo Soares Ferreira, Ricardo Rodrigues |
author_facet | Barsotti, Carlos Eduardo Gavassi, Bruno Moreira Prado, Francisco Eugenio Batista, Bernardo Nogueira de Resende Pratali, Raphael Ribeiro, Ana Paula de Oliveira, Carlos Eduardo Soares Ferreira, Ricardo Rodrigues |
author_sort | Barsotti, Carlos Eduardo |
collection | PubMed |
description | BACKGROUND: To investigate in the conventional techniques of the pedicle screws using triggered screw electromyography (t-EMG), considering different threshold cutoffs: 10, 15, 20 25 mA, for predicting pedicle screw positioning during surgery of the adolescent with idiopathic scoliosis (AIS). METHODS: Sixteen patients (4 males, 12 females, average age 16.6 years) were included, with an average curve magnitude of 50 degrees and placement of 226 pedicle screws. Each screw was classified as “at risk for nerve injury” (ARNI) or “no risk for nerve injury” (NRNI) using CT and the diagnostic accuracy of EMG considering different threshold cutoffs (10,15, 20 and 25 mA) in the axial and Sagittal planes for predicting screw positions ARNI was investigated. RESULTS: The EMG exam accuracy, in the axial plane, 90.3% screws were considered NRNI. In the sagittal plane, 81% pedicle screws were considered NRNI. A 1-mA decrease in the EMG threshold was associated with a 12% increase in the odds of the screw position ARNI. In the axial and sagittal planes, the ORs were 1.09 and 1.12, respectively. At every threshold cutoff evaluated, the PPV of EMG for predicting screws ARNI was very low in the different threshold cutoff (10 and 15); the highest PPV was 18% with a threshold cutoff of 25 mA. The PPV was always slightly higher for predicting screws ARNI in the sagittal plane than in the axial plane. In contrast, there was a moderate to high NPV (78–93%) for every cutoff analyzed. CONCLUSIONS: EMG had a moderate to high accuracy for positive predicting value screws ARNI with increase threshold cutoffs of 20 and 25 mA. In addition, showed to be effective for minimizing false-negative screws ARNI in the different threshold cutoffs of the EMG in adolescent with idiopathic scoliosis (AIS). |
format | Online Article Text |
id | pubmed-7372782 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-73727822020-07-21 Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study Barsotti, Carlos Eduardo Gavassi, Bruno Moreira Prado, Francisco Eugenio Batista, Bernardo Nogueira de Resende Pratali, Raphael Ribeiro, Ana Paula de Oliveira, Carlos Eduardo Soares Ferreira, Ricardo Rodrigues BMC Musculoskelet Disord Research Article BACKGROUND: To investigate in the conventional techniques of the pedicle screws using triggered screw electromyography (t-EMG), considering different threshold cutoffs: 10, 15, 20 25 mA, for predicting pedicle screw positioning during surgery of the adolescent with idiopathic scoliosis (AIS). METHODS: Sixteen patients (4 males, 12 females, average age 16.6 years) were included, with an average curve magnitude of 50 degrees and placement of 226 pedicle screws. Each screw was classified as “at risk for nerve injury” (ARNI) or “no risk for nerve injury” (NRNI) using CT and the diagnostic accuracy of EMG considering different threshold cutoffs (10,15, 20 and 25 mA) in the axial and Sagittal planes for predicting screw positions ARNI was investigated. RESULTS: The EMG exam accuracy, in the axial plane, 90.3% screws were considered NRNI. In the sagittal plane, 81% pedicle screws were considered NRNI. A 1-mA decrease in the EMG threshold was associated with a 12% increase in the odds of the screw position ARNI. In the axial and sagittal planes, the ORs were 1.09 and 1.12, respectively. At every threshold cutoff evaluated, the PPV of EMG for predicting screws ARNI was very low in the different threshold cutoff (10 and 15); the highest PPV was 18% with a threshold cutoff of 25 mA. The PPV was always slightly higher for predicting screws ARNI in the sagittal plane than in the axial plane. In contrast, there was a moderate to high NPV (78–93%) for every cutoff analyzed. CONCLUSIONS: EMG had a moderate to high accuracy for positive predicting value screws ARNI with increase threshold cutoffs of 20 and 25 mA. In addition, showed to be effective for minimizing false-negative screws ARNI in the different threshold cutoffs of the EMG in adolescent with idiopathic scoliosis (AIS). BioMed Central 2020-07-20 /pmc/articles/PMC7372782/ /pubmed/32689992 http://dx.doi.org/10.1186/s12891-020-03491-z Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Barsotti, Carlos Eduardo Gavassi, Bruno Moreira Prado, Francisco Eugenio Batista, Bernardo Nogueira de Resende Pratali, Raphael Ribeiro, Ana Paula de Oliveira, Carlos Eduardo Soares Ferreira, Ricardo Rodrigues Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study |
title | Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study |
title_full | Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study |
title_fullStr | Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study |
title_full_unstemmed | Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study |
title_short | Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study |
title_sort | diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7372782/ https://www.ncbi.nlm.nih.gov/pubmed/32689992 http://dx.doi.org/10.1186/s12891-020-03491-z |
work_keys_str_mv | AT barsotticarloseduardo diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy AT gavassibrunomoreira diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy AT pradofranciscoeugenio diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy AT batistabernardonogueira diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy AT deresendeprataliraphael diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy AT ribeiroanapaula diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy AT deoliveiracarloseduardosoares diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy AT ferreiraricardorodrigues diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy |