BACKGROUND: To investigate in the conventional techniques of the pedicle screws using triggered screw electromyography (t-EMG), considering different threshold cutoffs: 10, 15, 20 25 mA, for predicting pedicle screw positioning during surgery of the adolescent with idiopathic scoliosis (AIS). METHOD...

Descripción completa

Detalles Bibliográficos
Autores principales: Barsotti, Carlos Eduardo, Gavassi, Bruno Moreira, Prado, Francisco Eugenio, Batista, Bernardo Nogueira, de Resende Pratali, Raphael, Ribeiro, Ana Paula, de Oliveira, Carlos Eduardo Soares, Ferreira, Ricardo Rodrigues
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7372782/
https://www.ncbi.nlm.nih.gov/pubmed/32689992
http://dx.doi.org/10.1186/s12891-020-03491-z
_version_ 1783561380815699968
author Barsotti, Carlos Eduardo
Gavassi, Bruno Moreira
Prado, Francisco Eugenio
Batista, Bernardo Nogueira
de Resende Pratali, Raphael
Ribeiro, Ana Paula
de Oliveira, Carlos Eduardo Soares
Ferreira, Ricardo Rodrigues
author_facet Barsotti, Carlos Eduardo
Gavassi, Bruno Moreira
Prado, Francisco Eugenio
Batista, Bernardo Nogueira
de Resende Pratali, Raphael
Ribeiro, Ana Paula
de Oliveira, Carlos Eduardo Soares
Ferreira, Ricardo Rodrigues
author_sort Barsotti, Carlos Eduardo
collection PubMed
description BACKGROUND: To investigate in the conventional techniques of the pedicle screws using triggered screw electromyography (t-EMG), considering different threshold cutoffs: 10, 15, 20 25 mA, for predicting pedicle screw positioning during surgery of the adolescent with idiopathic scoliosis (AIS). METHODS: Sixteen patients (4 males, 12 females, average age 16.6 years) were included, with an average curve magnitude of 50 degrees and placement of 226 pedicle screws. Each screw was classified as “at risk for nerve injury” (ARNI) or “no risk for nerve injury” (NRNI) using CT and the diagnostic accuracy of EMG considering different threshold cutoffs (10,15, 20 and 25 mA) in the axial and Sagittal planes for predicting screw positions ARNI was investigated. RESULTS: The EMG exam accuracy, in the axial plane, 90.3% screws were considered NRNI. In the sagittal plane, 81% pedicle screws were considered NRNI. A 1-mA decrease in the EMG threshold was associated with a 12% increase in the odds of the screw position ARNI. In the axial and sagittal planes, the ORs were 1.09 and 1.12, respectively. At every threshold cutoff evaluated, the PPV of EMG for predicting screws ARNI was very low in the different threshold cutoff (10 and 15); the highest PPV was 18% with a threshold cutoff of 25 mA. The PPV was always slightly higher for predicting screws ARNI in the sagittal plane than in the axial plane. In contrast, there was a moderate to high NPV (78–93%) for every cutoff analyzed. CONCLUSIONS: EMG had a moderate to high accuracy for positive predicting value screws ARNI with increase threshold cutoffs of 20 and 25 mA. In addition, showed to be effective for minimizing false-negative screws ARNI in the different threshold cutoffs of the EMG in adolescent with idiopathic scoliosis (AIS).
format Online
Article
Text
id pubmed-7372782
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-73727822020-07-21 Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study Barsotti, Carlos Eduardo Gavassi, Bruno Moreira Prado, Francisco Eugenio Batista, Bernardo Nogueira de Resende Pratali, Raphael Ribeiro, Ana Paula de Oliveira, Carlos Eduardo Soares Ferreira, Ricardo Rodrigues BMC Musculoskelet Disord Research Article BACKGROUND: To investigate in the conventional techniques of the pedicle screws using triggered screw electromyography (t-EMG), considering different threshold cutoffs: 10, 15, 20 25 mA, for predicting pedicle screw positioning during surgery of the adolescent with idiopathic scoliosis (AIS). METHODS: Sixteen patients (4 males, 12 females, average age 16.6 years) were included, with an average curve magnitude of 50 degrees and placement of 226 pedicle screws. Each screw was classified as “at risk for nerve injury” (ARNI) or “no risk for nerve injury” (NRNI) using CT and the diagnostic accuracy of EMG considering different threshold cutoffs (10,15, 20 and 25 mA) in the axial and Sagittal planes for predicting screw positions ARNI was investigated. RESULTS: The EMG exam accuracy, in the axial plane, 90.3% screws were considered NRNI. In the sagittal plane, 81% pedicle screws were considered NRNI. A 1-mA decrease in the EMG threshold was associated with a 12% increase in the odds of the screw position ARNI. In the axial and sagittal planes, the ORs were 1.09 and 1.12, respectively. At every threshold cutoff evaluated, the PPV of EMG for predicting screws ARNI was very low in the different threshold cutoff (10 and 15); the highest PPV was 18% with a threshold cutoff of 25 mA. The PPV was always slightly higher for predicting screws ARNI in the sagittal plane than in the axial plane. In contrast, there was a moderate to high NPV (78–93%) for every cutoff analyzed. CONCLUSIONS: EMG had a moderate to high accuracy for positive predicting value screws ARNI with increase threshold cutoffs of 20 and 25 mA. In addition, showed to be effective for minimizing false-negative screws ARNI in the different threshold cutoffs of the EMG in adolescent with idiopathic scoliosis (AIS). BioMed Central 2020-07-20 /pmc/articles/PMC7372782/ /pubmed/32689992 http://dx.doi.org/10.1186/s12891-020-03491-z Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Barsotti, Carlos Eduardo
Gavassi, Bruno Moreira
Prado, Francisco Eugenio
Batista, Bernardo Nogueira
de Resende Pratali, Raphael
Ribeiro, Ana Paula
de Oliveira, Carlos Eduardo Soares
Ferreira, Ricardo Rodrigues
Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study
title Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study
title_full Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study
title_fullStr Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study
title_full_unstemmed Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study
title_short Diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study
title_sort diagnostic accuracy of perioperative electromyography in the positioning of pedicle screws in adolescent idiopathic scoliosis treatment: a cross-sectional diagnostic study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7372782/
https://www.ncbi.nlm.nih.gov/pubmed/32689992
http://dx.doi.org/10.1186/s12891-020-03491-z
work_keys_str_mv AT barsotticarloseduardo diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy
AT gavassibrunomoreira diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy
AT pradofranciscoeugenio diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy
AT batistabernardonogueira diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy
AT deresendeprataliraphael diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy
AT ribeiroanapaula diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy
AT deoliveiracarloseduardosoares diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy
AT ferreiraricardorodrigues diagnosticaccuracyofperioperativeelectromyographyinthepositioningofpediclescrewsinadolescentidiopathicscoliosistreatmentacrosssectionaldiagnosticstudy