Cargando…

Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis

STUDY DESIGN: Systematic review and meta-analysis. AIM: The purpose of this study was to compare the safety and accuracy of the C2 pedicle versus C2 pars screws placement and free-hand technique versus navigation for upper cervical fusion patients. METHODS: Databases searched included PubMed, Scopus...

Descripción completa

Detalles Bibliográficos
Autores principales: Azimi, Parisa, Yazdanian, Taravat, Benzel, Edward C., Aghaei, Hossein Nayeb, Azhari, Shirzad, Sadeghi, Sohrab, Montazeri, Ali
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7372824/
https://www.ncbi.nlm.nih.gov/pubmed/32690035
http://dx.doi.org/10.1186/s13018-020-01798-0
_version_ 1783561389722304512
author Azimi, Parisa
Yazdanian, Taravat
Benzel, Edward C.
Aghaei, Hossein Nayeb
Azhari, Shirzad
Sadeghi, Sohrab
Montazeri, Ali
author_facet Azimi, Parisa
Yazdanian, Taravat
Benzel, Edward C.
Aghaei, Hossein Nayeb
Azhari, Shirzad
Sadeghi, Sohrab
Montazeri, Ali
author_sort Azimi, Parisa
collection PubMed
description STUDY DESIGN: Systematic review and meta-analysis. AIM: The purpose of this study was to compare the safety and accuracy of the C2 pedicle versus C2 pars screws placement and free-hand technique versus navigation for upper cervical fusion patients. METHODS: Databases searched included PubMed, Scopus, Web of Science, and Cochrane Library to identify all papers published up to April 2020 that have evaluated C2 pedicle/pars screws placement accuracy. Two authors individually screened the literature according to the inclusion and exclusion criteria. The accuracy rates associated with C2 pedicle/pars were extracted. The pooled accuracy rate estimated was performed by the CMA software. A funnel plot based on accuracy rate estimate was used to evaluate publication bias. RESULTS: From 1123 potentially relevant studies, 142 full-text publications were screened. We analyzed data from 79 studies involving 4431 patients with 6026 C2 pedicle or pars screw placement. We used the Newcastle-Ottawa Scale (NOS) to evaluate the quality of studies included in this review. Overall, funnel plot and Begg’s test did not indicate obvious publication bias. The pooled analysis reveals that the accuracy rates were 93.8% for C2 pedicle screw free-hand, 93.7% for pars screw free-hand, 92.2% for navigated C2 pedicle screw, and 86.2% for navigated C2 pars screw (all, P value < 0.001). No statistically significant differences were observed between the accuracy of placement C2 pedicle versus C2 pars screws with the free-hand technique and the free-hand C2 pedicle group versus the navigated C2 pedicle group (all, P value > 0.05). CONCLUSION: Overall, there was no difference in the safety and accuracy between the free-hand and navigated techniques. Further well-conducted studies with detailed stratification are needed to complement our findings.
format Online
Article
Text
id pubmed-7372824
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-73728242020-07-21 Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis Azimi, Parisa Yazdanian, Taravat Benzel, Edward C. Aghaei, Hossein Nayeb Azhari, Shirzad Sadeghi, Sohrab Montazeri, Ali J Orthop Surg Res Systematic Review STUDY DESIGN: Systematic review and meta-analysis. AIM: The purpose of this study was to compare the safety and accuracy of the C2 pedicle versus C2 pars screws placement and free-hand technique versus navigation for upper cervical fusion patients. METHODS: Databases searched included PubMed, Scopus, Web of Science, and Cochrane Library to identify all papers published up to April 2020 that have evaluated C2 pedicle/pars screws placement accuracy. Two authors individually screened the literature according to the inclusion and exclusion criteria. The accuracy rates associated with C2 pedicle/pars were extracted. The pooled accuracy rate estimated was performed by the CMA software. A funnel plot based on accuracy rate estimate was used to evaluate publication bias. RESULTS: From 1123 potentially relevant studies, 142 full-text publications were screened. We analyzed data from 79 studies involving 4431 patients with 6026 C2 pedicle or pars screw placement. We used the Newcastle-Ottawa Scale (NOS) to evaluate the quality of studies included in this review. Overall, funnel plot and Begg’s test did not indicate obvious publication bias. The pooled analysis reveals that the accuracy rates were 93.8% for C2 pedicle screw free-hand, 93.7% for pars screw free-hand, 92.2% for navigated C2 pedicle screw, and 86.2% for navigated C2 pars screw (all, P value < 0.001). No statistically significant differences were observed between the accuracy of placement C2 pedicle versus C2 pars screws with the free-hand technique and the free-hand C2 pedicle group versus the navigated C2 pedicle group (all, P value > 0.05). CONCLUSION: Overall, there was no difference in the safety and accuracy between the free-hand and navigated techniques. Further well-conducted studies with detailed stratification are needed to complement our findings. BioMed Central 2020-07-20 /pmc/articles/PMC7372824/ /pubmed/32690035 http://dx.doi.org/10.1186/s13018-020-01798-0 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Systematic Review
Azimi, Parisa
Yazdanian, Taravat
Benzel, Edward C.
Aghaei, Hossein Nayeb
Azhari, Shirzad
Sadeghi, Sohrab
Montazeri, Ali
Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis
title Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis
title_full Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis
title_fullStr Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis
title_full_unstemmed Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis
title_short Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis
title_sort accuracy and safety of c2 pedicle or pars screw placement: a systematic review and meta-analysis
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7372824/
https://www.ncbi.nlm.nih.gov/pubmed/32690035
http://dx.doi.org/10.1186/s13018-020-01798-0
work_keys_str_mv AT azimiparisa accuracyandsafetyofc2pedicleorparsscrewplacementasystematicreviewandmetaanalysis
AT yazdaniantaravat accuracyandsafetyofc2pedicleorparsscrewplacementasystematicreviewandmetaanalysis
AT benzeledwardc accuracyandsafetyofc2pedicleorparsscrewplacementasystematicreviewandmetaanalysis
AT aghaeihosseinnayeb accuracyandsafetyofc2pedicleorparsscrewplacementasystematicreviewandmetaanalysis
AT azharishirzad accuracyandsafetyofc2pedicleorparsscrewplacementasystematicreviewandmetaanalysis
AT sadeghisohrab accuracyandsafetyofc2pedicleorparsscrewplacementasystematicreviewandmetaanalysis
AT montazeriali accuracyandsafetyofc2pedicleorparsscrewplacementasystematicreviewandmetaanalysis