Pacemaker implantation after aortic valve replacement: rapid-deployment Intuity(®) compared to conventional bioprostheses

OBJECTIVES: The aim of this study was to compare the incidence of permanent pacemaker (PPM) implantation after aortic valve replacement by rapid-deployment bioprosthesis (RDB) and standard valve (Standard). METHODS: All patients undergoing aortic valve replacement between 2015 and 2018, in 1 centre,...