Cargando…
Glucose Oxidase/Nano-ZnO/Thin Film Deposit FTO as an Innovative Clinical Transducer: A Sensitive Glucose Biosensor
In the present research, a new biocompatible electrode is proposed as a rapid and direct glucose biosensing technique that improves on the deficiencies of fast clinical devices in laboratory investigations. Nano-ZnO (nanostructured zinc oxide) was sputtered by reactive direct current magnetron sputt...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7374262/ https://www.ncbi.nlm.nih.gov/pubmed/32760694 http://dx.doi.org/10.3389/fchem.2020.00503 |
_version_ | 1783561658711408640 |
---|---|
author | Naderi Asrami, Padideh Aberoomand Azar, Parviz Saber Tehrani, Mohammad Mozaffari, Sayed Ahmad |
author_facet | Naderi Asrami, Padideh Aberoomand Azar, Parviz Saber Tehrani, Mohammad Mozaffari, Sayed Ahmad |
author_sort | Naderi Asrami, Padideh |
collection | PubMed |
description | In the present research, a new biocompatible electrode is proposed as a rapid and direct glucose biosensing technique that improves on the deficiencies of fast clinical devices in laboratory investigations. Nano-ZnO (nanostructured zinc oxide) was sputtered by reactive direct current magnetron sputtering system on a precovered fluorinated tin oxide (FTO) conductive layer. Spin-coated polyvinyl alcohol (PVA) at optimized instrumental deposition conditions was applied to prepare the effective medium for glucose oxidase enzyme (GOx) covalent immobilization through cyanuric chloride (GOx/nano-ZnO/PVA/FTO). The electrochemical behavior of glucose on the fabricated GOx/nano-ZnO/PVA/FTO biosensor was investigated by I-V techniques. In addition, field emission scanning electron microscopy and electrochemical impedance spectroscopy were applied to assess the morphology of the modified electrode surface. The I-V results indicated good sensitivity for glucose detection (0.041 mA per mM) within 0.2–20 mM and the limit of detection was 2.0 μM. We believe that such biodevices have good potential for tracing a number of biocompounds in biological fluids along with excellent accuracy, selectivity, and precise analysis. The fast response time of the fabricated GOx/nano-ZnO/PVA/FTO biosensor (less than 3 s) could allow most types of real-time analysis. |
format | Online Article Text |
id | pubmed-7374262 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-73742622020-08-04 Glucose Oxidase/Nano-ZnO/Thin Film Deposit FTO as an Innovative Clinical Transducer: A Sensitive Glucose Biosensor Naderi Asrami, Padideh Aberoomand Azar, Parviz Saber Tehrani, Mohammad Mozaffari, Sayed Ahmad Front Chem Chemistry In the present research, a new biocompatible electrode is proposed as a rapid and direct glucose biosensing technique that improves on the deficiencies of fast clinical devices in laboratory investigations. Nano-ZnO (nanostructured zinc oxide) was sputtered by reactive direct current magnetron sputtering system on a precovered fluorinated tin oxide (FTO) conductive layer. Spin-coated polyvinyl alcohol (PVA) at optimized instrumental deposition conditions was applied to prepare the effective medium for glucose oxidase enzyme (GOx) covalent immobilization through cyanuric chloride (GOx/nano-ZnO/PVA/FTO). The electrochemical behavior of glucose on the fabricated GOx/nano-ZnO/PVA/FTO biosensor was investigated by I-V techniques. In addition, field emission scanning electron microscopy and electrochemical impedance spectroscopy were applied to assess the morphology of the modified electrode surface. The I-V results indicated good sensitivity for glucose detection (0.041 mA per mM) within 0.2–20 mM and the limit of detection was 2.0 μM. We believe that such biodevices have good potential for tracing a number of biocompounds in biological fluids along with excellent accuracy, selectivity, and precise analysis. The fast response time of the fabricated GOx/nano-ZnO/PVA/FTO biosensor (less than 3 s) could allow most types of real-time analysis. Frontiers Media S.A. 2020-07-15 /pmc/articles/PMC7374262/ /pubmed/32760694 http://dx.doi.org/10.3389/fchem.2020.00503 Text en Copyright © 2020 Naderi Asrami, Aberoomand Azar, Saber Tehrani and Mozaffari. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Chemistry Naderi Asrami, Padideh Aberoomand Azar, Parviz Saber Tehrani, Mohammad Mozaffari, Sayed Ahmad Glucose Oxidase/Nano-ZnO/Thin Film Deposit FTO as an Innovative Clinical Transducer: A Sensitive Glucose Biosensor |
title | Glucose Oxidase/Nano-ZnO/Thin Film Deposit FTO as an Innovative Clinical Transducer: A Sensitive Glucose Biosensor |
title_full | Glucose Oxidase/Nano-ZnO/Thin Film Deposit FTO as an Innovative Clinical Transducer: A Sensitive Glucose Biosensor |
title_fullStr | Glucose Oxidase/Nano-ZnO/Thin Film Deposit FTO as an Innovative Clinical Transducer: A Sensitive Glucose Biosensor |
title_full_unstemmed | Glucose Oxidase/Nano-ZnO/Thin Film Deposit FTO as an Innovative Clinical Transducer: A Sensitive Glucose Biosensor |
title_short | Glucose Oxidase/Nano-ZnO/Thin Film Deposit FTO as an Innovative Clinical Transducer: A Sensitive Glucose Biosensor |
title_sort | glucose oxidase/nano-zno/thin film deposit fto as an innovative clinical transducer: a sensitive glucose biosensor |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7374262/ https://www.ncbi.nlm.nih.gov/pubmed/32760694 http://dx.doi.org/10.3389/fchem.2020.00503 |
work_keys_str_mv | AT naderiasramipadideh glucoseoxidasenanoznothinfilmdepositftoasaninnovativeclinicaltransducerasensitiveglucosebiosensor AT aberoomandazarparviz glucoseoxidasenanoznothinfilmdepositftoasaninnovativeclinicaltransducerasensitiveglucosebiosensor AT sabertehranimohammad glucoseoxidasenanoznothinfilmdepositftoasaninnovativeclinicaltransducerasensitiveglucosebiosensor AT mozaffarisayedahmad glucoseoxidasenanoznothinfilmdepositftoasaninnovativeclinicaltransducerasensitiveglucosebiosensor |