Cargando…

Dry Electrodes for Human Bioelectrical Signal Monitoring

Bioelectrical or electrophysiological signals generated by living cells or tissues during daily physiological activities are closely related to the state of the body and organ functions, and therefore are widely used in clinical diagnosis, health monitoring, intelligent control and human-computer in...

Descripción completa

Detalles Bibliográficos
Autores principales: Fu, Yulin, Zhao, Jingjing, Dong, Ying, Wang, Xiaohao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7374322/
https://www.ncbi.nlm.nih.gov/pubmed/32610658
http://dx.doi.org/10.3390/s20133651
_version_ 1783561672011546624
author Fu, Yulin
Zhao, Jingjing
Dong, Ying
Wang, Xiaohao
author_facet Fu, Yulin
Zhao, Jingjing
Dong, Ying
Wang, Xiaohao
author_sort Fu, Yulin
collection PubMed
description Bioelectrical or electrophysiological signals generated by living cells or tissues during daily physiological activities are closely related to the state of the body and organ functions, and therefore are widely used in clinical diagnosis, health monitoring, intelligent control and human-computer interaction. Ag/AgCl electrodes with wet conductive gels are widely used to pick up these bioelectrical signals using electrodes and record them in the form of electroencephalograms, electrocardiograms, electromyography, electrooculograms, etc. However, the inconvenience, instability and infection problems resulting from the use of gel with Ag/AgCl wet electrodes can’t meet the needs of long-term signal acquisition, especially in wearable applications. Hence, focus has shifted toward the study of dry electrodes that can work without gels or adhesives. In this paper, a retrospective overview of the development of dry electrodes used for monitoring bioelectrical signals is provided, including the sensing principles, material selection, device preparation, and measurement performance. In addition, the challenges regarding the limitations of materials, fabrication technologies and wearable performance of dry electrodes are discussed. Finally, the development obstacles and application advantages of different dry electrodes are analyzed to make a comparison and reveal research directions for future studies.
format Online
Article
Text
id pubmed-7374322
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73743222020-08-06 Dry Electrodes for Human Bioelectrical Signal Monitoring Fu, Yulin Zhao, Jingjing Dong, Ying Wang, Xiaohao Sensors (Basel) Review Bioelectrical or electrophysiological signals generated by living cells or tissues during daily physiological activities are closely related to the state of the body and organ functions, and therefore are widely used in clinical diagnosis, health monitoring, intelligent control and human-computer interaction. Ag/AgCl electrodes with wet conductive gels are widely used to pick up these bioelectrical signals using electrodes and record them in the form of electroencephalograms, electrocardiograms, electromyography, electrooculograms, etc. However, the inconvenience, instability and infection problems resulting from the use of gel with Ag/AgCl wet electrodes can’t meet the needs of long-term signal acquisition, especially in wearable applications. Hence, focus has shifted toward the study of dry electrodes that can work without gels or adhesives. In this paper, a retrospective overview of the development of dry electrodes used for monitoring bioelectrical signals is provided, including the sensing principles, material selection, device preparation, and measurement performance. In addition, the challenges regarding the limitations of materials, fabrication technologies and wearable performance of dry electrodes are discussed. Finally, the development obstacles and application advantages of different dry electrodes are analyzed to make a comparison and reveal research directions for future studies. MDPI 2020-06-29 /pmc/articles/PMC7374322/ /pubmed/32610658 http://dx.doi.org/10.3390/s20133651 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Fu, Yulin
Zhao, Jingjing
Dong, Ying
Wang, Xiaohao
Dry Electrodes for Human Bioelectrical Signal Monitoring
title Dry Electrodes for Human Bioelectrical Signal Monitoring
title_full Dry Electrodes for Human Bioelectrical Signal Monitoring
title_fullStr Dry Electrodes for Human Bioelectrical Signal Monitoring
title_full_unstemmed Dry Electrodes for Human Bioelectrical Signal Monitoring
title_short Dry Electrodes for Human Bioelectrical Signal Monitoring
title_sort dry electrodes for human bioelectrical signal monitoring
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7374322/
https://www.ncbi.nlm.nih.gov/pubmed/32610658
http://dx.doi.org/10.3390/s20133651
work_keys_str_mv AT fuyulin dryelectrodesforhumanbioelectricalsignalmonitoring
AT zhaojingjing dryelectrodesforhumanbioelectricalsignalmonitoring
AT dongying dryelectrodesforhumanbioelectricalsignalmonitoring
AT wangxiaohao dryelectrodesforhumanbioelectricalsignalmonitoring