Cargando…

Analysis and Testing of a Suitable Compatible Electrode’s Material for Continuous Measurement of Glucose Concentration

The subject of the submitted work is the proposal of electrodes for the continual measurement of the glucose concentration for the purpose of specifying further hemodynamic parameters. The proposal includes the design of the electronic measuring system, the construction of the electrodes themselves...

Descripción completa

Detalles Bibliográficos
Autores principales: Slaninova, Nikola, Fiedorova, Klara, Selamat, Ali, Danisova, Karolina, Kubicek, Jan, Tkacz, Ewaryst, Augustynek, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7374362/
https://www.ncbi.nlm.nih.gov/pubmed/32629993
http://dx.doi.org/10.3390/s20133666
_version_ 1783561681305075712
author Slaninova, Nikola
Fiedorova, Klara
Selamat, Ali
Danisova, Karolina
Kubicek, Jan
Tkacz, Ewaryst
Augustynek, Martin
author_facet Slaninova, Nikola
Fiedorova, Klara
Selamat, Ali
Danisova, Karolina
Kubicek, Jan
Tkacz, Ewaryst
Augustynek, Martin
author_sort Slaninova, Nikola
collection PubMed
description The subject of the submitted work is the proposal of electrodes for the continual measurement of the glucose concentration for the purpose of specifying further hemodynamic parameters. The proposal includes the design of the electronic measuring system, the construction of the electrodes themselves and the functionality of the entire system, verified experimentally using various electrode materials. The proposed circuit works on the basis of micro-ammeter measuring the size of the flowing electric current and the electrochemical measurement method is used for specifying the glucose concentration. The electrode system is comprised of two electrodes embedded in a silicon tube. The solution consists of the measurement with three types of materials, which are verified by using three solutions with a precisely given concentration of glucose in the form of a mixed solution and enzyme glucose oxidase. For the testing of the proposed circuit and the selection of a suitable material, the testing did not take place on measurements in whole blood. For the construction of the electrodes, the three most frequently used materials for the construction of electrodes used in clinical practice for sensing biopotentials, specifically the materials Ag/AgCl, Cu and Au, were used. The performed experiments showed that the material Ag/AgCl, which had the greatest sensitivity for the measurement even without the enzyme, was the most suitable material for the electrode. This conclusion is supported by the performed statistical analysis. On the basis of the testing, we can come to the conclusion that even if the Ag/AgCl electrode appears to be the most suitable, showing high stability, gold-plated electrodes showed stability throughout the measurement similarly to Ag/AgCl electrodes, but did not achieve the same qualities in sensitivity and readability of the measured results.
format Online
Article
Text
id pubmed-7374362
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73743622020-08-06 Analysis and Testing of a Suitable Compatible Electrode’s Material for Continuous Measurement of Glucose Concentration Slaninova, Nikola Fiedorova, Klara Selamat, Ali Danisova, Karolina Kubicek, Jan Tkacz, Ewaryst Augustynek, Martin Sensors (Basel) Article The subject of the submitted work is the proposal of electrodes for the continual measurement of the glucose concentration for the purpose of specifying further hemodynamic parameters. The proposal includes the design of the electronic measuring system, the construction of the electrodes themselves and the functionality of the entire system, verified experimentally using various electrode materials. The proposed circuit works on the basis of micro-ammeter measuring the size of the flowing electric current and the electrochemical measurement method is used for specifying the glucose concentration. The electrode system is comprised of two electrodes embedded in a silicon tube. The solution consists of the measurement with three types of materials, which are verified by using three solutions with a precisely given concentration of glucose in the form of a mixed solution and enzyme glucose oxidase. For the testing of the proposed circuit and the selection of a suitable material, the testing did not take place on measurements in whole blood. For the construction of the electrodes, the three most frequently used materials for the construction of electrodes used in clinical practice for sensing biopotentials, specifically the materials Ag/AgCl, Cu and Au, were used. The performed experiments showed that the material Ag/AgCl, which had the greatest sensitivity for the measurement even without the enzyme, was the most suitable material for the electrode. This conclusion is supported by the performed statistical analysis. On the basis of the testing, we can come to the conclusion that even if the Ag/AgCl electrode appears to be the most suitable, showing high stability, gold-plated electrodes showed stability throughout the measurement similarly to Ag/AgCl electrodes, but did not achieve the same qualities in sensitivity and readability of the measured results. MDPI 2020-06-30 /pmc/articles/PMC7374362/ /pubmed/32629993 http://dx.doi.org/10.3390/s20133666 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Slaninova, Nikola
Fiedorova, Klara
Selamat, Ali
Danisova, Karolina
Kubicek, Jan
Tkacz, Ewaryst
Augustynek, Martin
Analysis and Testing of a Suitable Compatible Electrode’s Material for Continuous Measurement of Glucose Concentration
title Analysis and Testing of a Suitable Compatible Electrode’s Material for Continuous Measurement of Glucose Concentration
title_full Analysis and Testing of a Suitable Compatible Electrode’s Material for Continuous Measurement of Glucose Concentration
title_fullStr Analysis and Testing of a Suitable Compatible Electrode’s Material for Continuous Measurement of Glucose Concentration
title_full_unstemmed Analysis and Testing of a Suitable Compatible Electrode’s Material for Continuous Measurement of Glucose Concentration
title_short Analysis and Testing of a Suitable Compatible Electrode’s Material for Continuous Measurement of Glucose Concentration
title_sort analysis and testing of a suitable compatible electrode’s material for continuous measurement of glucose concentration
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7374362/
https://www.ncbi.nlm.nih.gov/pubmed/32629993
http://dx.doi.org/10.3390/s20133666
work_keys_str_mv AT slaninovanikola analysisandtestingofasuitablecompatibleelectrodesmaterialforcontinuousmeasurementofglucoseconcentration
AT fiedorovaklara analysisandtestingofasuitablecompatibleelectrodesmaterialforcontinuousmeasurementofglucoseconcentration
AT selamatali analysisandtestingofasuitablecompatibleelectrodesmaterialforcontinuousmeasurementofglucoseconcentration
AT danisovakarolina analysisandtestingofasuitablecompatibleelectrodesmaterialforcontinuousmeasurementofglucoseconcentration
AT kubicekjan analysisandtestingofasuitablecompatibleelectrodesmaterialforcontinuousmeasurementofglucoseconcentration
AT tkaczewaryst analysisandtestingofasuitablecompatibleelectrodesmaterialforcontinuousmeasurementofglucoseconcentration
AT augustynekmartin analysisandtestingofasuitablecompatibleelectrodesmaterialforcontinuousmeasurementofglucoseconcentration