Skeletal muscle is considered as a near-constant volume system, and the contractions of the muscle are related to the changes in tissue thickness. Assessment of the skeletal muscle contractile parameters such as maximum contraction thickness ([Formula: see text]), contraction time ([Formula: see tex...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7374409/ https://www.ncbi.nlm.nih.gov/pubmed/32605006 http://dx.doi.org/10.3390/s20133616 |
_version_ | 1783561692518547456 |
---|---|
author | AlMohimeed, Ibrahim Ono, Yuu |
author_facet | AlMohimeed, Ibrahim Ono, Yuu |
author_sort | AlMohimeed, Ibrahim |
collection | PubMed |
description | Skeletal muscle is considered as a near-constant volume system, and the contractions of the muscle are related to the changes in tissue thickness. Assessment of the skeletal muscle contractile parameters such as maximum contraction thickness ([Formula: see text]), contraction time ([Formula: see text]), contraction velocity ([Formula: see text]), sustain time ([Formula: see text]), and half-relaxation ([Formula: see text]) provides valuable information for various medical applications. This paper presents a single-element wearable ultrasonic sensor (WUS) and a method to measure the skeletal muscle contractile parameters in A-mode ultrasonic data acquisition. The developed WUS was made of double-layer polyvinylidene fluoride (PVDF) piezoelectric polymer films with a simple and low-cost fabrication process. A flexible, lightweight, thin, and small size WUS would provide a secure attachment to the skin surface without affecting the muscle contraction dynamics of interest. The developed WUS was employed to monitor the contractions of gastrocnemius (GC) muscle of a human subject. The GC muscle contractions were evoked by the electrical muscle stimulation (EMS) at varying EMS frequencies from 2 Hz up to 30 Hz. The tissue thickness changes due to the muscle contractions were measured by utilizing a time-of-flight method in the ultrasonic through-transmission mode. The developed WUS demonstrated the capability to monitor the tissue thickness changes during the unfused and fused tetanic contractions. The tetanic progression level was quantitatively assessed using the parameter of the fusion index (FI) obtained. In addition, the contractile parameters ([Formula: see text] , [Formula: see text] , [Formula: see text] , [Formula: see text] , and [Formula: see text]) were successfully extracted from the measured tissue thickness changes. In addition, the unfused and fused tetanus frequencies were estimated from the obtained FI-EMS frequency curve. The WUS and ultrasonic method proposed in this study could be a valuable tool for inexpensive, non-invasive, and continuous monitoring of the skeletal muscle contractile properties. |
format | Online Article Text |
id | pubmed-7374409 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-73744092020-08-06 Ultrasound Measurement of Skeletal Muscle Contractile Parameters Using Flexible and Wearable Single-Element Ultrasonic Sensor AlMohimeed, Ibrahim Ono, Yuu Sensors (Basel) Article Skeletal muscle is considered as a near-constant volume system, and the contractions of the muscle are related to the changes in tissue thickness. Assessment of the skeletal muscle contractile parameters such as maximum contraction thickness ([Formula: see text]), contraction time ([Formula: see text]), contraction velocity ([Formula: see text]), sustain time ([Formula: see text]), and half-relaxation ([Formula: see text]) provides valuable information for various medical applications. This paper presents a single-element wearable ultrasonic sensor (WUS) and a method to measure the skeletal muscle contractile parameters in A-mode ultrasonic data acquisition. The developed WUS was made of double-layer polyvinylidene fluoride (PVDF) piezoelectric polymer films with a simple and low-cost fabrication process. A flexible, lightweight, thin, and small size WUS would provide a secure attachment to the skin surface without affecting the muscle contraction dynamics of interest. The developed WUS was employed to monitor the contractions of gastrocnemius (GC) muscle of a human subject. The GC muscle contractions were evoked by the electrical muscle stimulation (EMS) at varying EMS frequencies from 2 Hz up to 30 Hz. The tissue thickness changes due to the muscle contractions were measured by utilizing a time-of-flight method in the ultrasonic through-transmission mode. The developed WUS demonstrated the capability to monitor the tissue thickness changes during the unfused and fused tetanic contractions. The tetanic progression level was quantitatively assessed using the parameter of the fusion index (FI) obtained. In addition, the contractile parameters ([Formula: see text] , [Formula: see text] , [Formula: see text] , [Formula: see text] , and [Formula: see text]) were successfully extracted from the measured tissue thickness changes. In addition, the unfused and fused tetanus frequencies were estimated from the obtained FI-EMS frequency curve. The WUS and ultrasonic method proposed in this study could be a valuable tool for inexpensive, non-invasive, and continuous monitoring of the skeletal muscle contractile properties. MDPI 2020-06-27 /pmc/articles/PMC7374409/ /pubmed/32605006 http://dx.doi.org/10.3390/s20133616 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article AlMohimeed, Ibrahim Ono, Yuu Ultrasound Measurement of Skeletal Muscle Contractile Parameters Using Flexible and Wearable Single-Element Ultrasonic Sensor |
title | Ultrasound Measurement of Skeletal Muscle Contractile Parameters Using Flexible and Wearable Single-Element Ultrasonic Sensor |
title_full | Ultrasound Measurement of Skeletal Muscle Contractile Parameters Using Flexible and Wearable Single-Element Ultrasonic Sensor |
title_fullStr | Ultrasound Measurement of Skeletal Muscle Contractile Parameters Using Flexible and Wearable Single-Element Ultrasonic Sensor |
title_full_unstemmed | Ultrasound Measurement of Skeletal Muscle Contractile Parameters Using Flexible and Wearable Single-Element Ultrasonic Sensor |
title_short | Ultrasound Measurement of Skeletal Muscle Contractile Parameters Using Flexible and Wearable Single-Element Ultrasonic Sensor |
title_sort | ultrasound measurement of skeletal muscle contractile parameters using flexible and wearable single-element ultrasonic sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7374409/ https://www.ncbi.nlm.nih.gov/pubmed/32605006 http://dx.doi.org/10.3390/s20133616 |
work_keys_str_mv | AT almohimeedibrahim ultrasoundmeasurementofskeletalmusclecontractileparametersusingflexibleandwearablesingleelementultrasonicsensor AT onoyuu ultrasoundmeasurementofskeletalmusclecontractileparametersusingflexibleandwearablesingleelementultrasonicsensor |