Cargando…

Atomic Force Microscopy Imaging in Turbid Liquids: A Promising Tool in Nanomedicine

Tracking of biological and physiological processes on the nanoscale is a central part of the growing field of nanomedicine. Although atomic force microscopy (AFM) is one of the most appropriate techniques in this area, investigations in non-transparent fluids such as human blood are not possible wit...

Descripción completa

Detalles Bibliográficos
Autores principales: Leitner, Michael, Seferovic, Hannah, Stainer, Sarah, Buchroithner, Boris, Schwalb, Christian H., Deutschinger, Alexander, Ebner, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7374447/
https://www.ncbi.nlm.nih.gov/pubmed/32630829
http://dx.doi.org/10.3390/s20133715
_version_ 1783561701244796928
author Leitner, Michael
Seferovic, Hannah
Stainer, Sarah
Buchroithner, Boris
Schwalb, Christian H.
Deutschinger, Alexander
Ebner, Andreas
author_facet Leitner, Michael
Seferovic, Hannah
Stainer, Sarah
Buchroithner, Boris
Schwalb, Christian H.
Deutschinger, Alexander
Ebner, Andreas
author_sort Leitner, Michael
collection PubMed
description Tracking of biological and physiological processes on the nanoscale is a central part of the growing field of nanomedicine. Although atomic force microscopy (AFM) is one of the most appropriate techniques in this area, investigations in non-transparent fluids such as human blood are not possible with conventional AFMs due to limitations caused by the optical readout. Here, we show a promising approach based on self-sensing cantilevers (SSC) as a replacement for optical readout in biological AFM imaging. Piezo-resistors, in the form of a Wheatstone bridge, are embedded into the cantilever, whereas two of them are placed at the bending edge. This enables the deflection of the cantilever to be precisely recorded by measuring the changes in resistance. Furthermore, the conventional acoustic or magnetic vibration excitation in intermittent contact mode can be replaced by a thermal excitation using a heating loop. We show further developments of existing approaches enabling stable measurements in turbid liquids. Different readout and excitation methods are compared under various environmental conditions, ranging from dry state to human blood. To demonstrate the applicability of our laser-free bio-AFM for nanomedical research, we have selected the hemostatic process of blood coagulation as well as ultra-flat red blood cells in different turbid fluids. Furthermore, the effects on noise and scanning speed of different media are compared. The technical realization is shown (1) on a conventional optical beam deflection (OBD)-based AFM, where we replaced the optical part by a new SSC nose cone, and (2) on an all-electric AFM, which we adapted for measurements in turbid liquids.
format Online
Article
Text
id pubmed-7374447
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73744472020-08-06 Atomic Force Microscopy Imaging in Turbid Liquids: A Promising Tool in Nanomedicine Leitner, Michael Seferovic, Hannah Stainer, Sarah Buchroithner, Boris Schwalb, Christian H. Deutschinger, Alexander Ebner, Andreas Sensors (Basel) Article Tracking of biological and physiological processes on the nanoscale is a central part of the growing field of nanomedicine. Although atomic force microscopy (AFM) is one of the most appropriate techniques in this area, investigations in non-transparent fluids such as human blood are not possible with conventional AFMs due to limitations caused by the optical readout. Here, we show a promising approach based on self-sensing cantilevers (SSC) as a replacement for optical readout in biological AFM imaging. Piezo-resistors, in the form of a Wheatstone bridge, are embedded into the cantilever, whereas two of them are placed at the bending edge. This enables the deflection of the cantilever to be precisely recorded by measuring the changes in resistance. Furthermore, the conventional acoustic or magnetic vibration excitation in intermittent contact mode can be replaced by a thermal excitation using a heating loop. We show further developments of existing approaches enabling stable measurements in turbid liquids. Different readout and excitation methods are compared under various environmental conditions, ranging from dry state to human blood. To demonstrate the applicability of our laser-free bio-AFM for nanomedical research, we have selected the hemostatic process of blood coagulation as well as ultra-flat red blood cells in different turbid fluids. Furthermore, the effects on noise and scanning speed of different media are compared. The technical realization is shown (1) on a conventional optical beam deflection (OBD)-based AFM, where we replaced the optical part by a new SSC nose cone, and (2) on an all-electric AFM, which we adapted for measurements in turbid liquids. MDPI 2020-07-02 /pmc/articles/PMC7374447/ /pubmed/32630829 http://dx.doi.org/10.3390/s20133715 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Leitner, Michael
Seferovic, Hannah
Stainer, Sarah
Buchroithner, Boris
Schwalb, Christian H.
Deutschinger, Alexander
Ebner, Andreas
Atomic Force Microscopy Imaging in Turbid Liquids: A Promising Tool in Nanomedicine
title Atomic Force Microscopy Imaging in Turbid Liquids: A Promising Tool in Nanomedicine
title_full Atomic Force Microscopy Imaging in Turbid Liquids: A Promising Tool in Nanomedicine
title_fullStr Atomic Force Microscopy Imaging in Turbid Liquids: A Promising Tool in Nanomedicine
title_full_unstemmed Atomic Force Microscopy Imaging in Turbid Liquids: A Promising Tool in Nanomedicine
title_short Atomic Force Microscopy Imaging in Turbid Liquids: A Promising Tool in Nanomedicine
title_sort atomic force microscopy imaging in turbid liquids: a promising tool in nanomedicine
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7374447/
https://www.ncbi.nlm.nih.gov/pubmed/32630829
http://dx.doi.org/10.3390/s20133715
work_keys_str_mv AT leitnermichael atomicforcemicroscopyimaginginturbidliquidsapromisingtoolinnanomedicine
AT seferovichannah atomicforcemicroscopyimaginginturbidliquidsapromisingtoolinnanomedicine
AT stainersarah atomicforcemicroscopyimaginginturbidliquidsapromisingtoolinnanomedicine
AT buchroithnerboris atomicforcemicroscopyimaginginturbidliquidsapromisingtoolinnanomedicine
AT schwalbchristianh atomicforcemicroscopyimaginginturbidliquidsapromisingtoolinnanomedicine
AT deutschingeralexander atomicforcemicroscopyimaginginturbidliquidsapromisingtoolinnanomedicine
AT ebnerandreas atomicforcemicroscopyimaginginturbidliquidsapromisingtoolinnanomedicine