Cargando…

Direct Catalytic Fuel Cell Device Coupled to Chemometric Methods to Detect Organic Compounds of Pharmaceutical and Biomedical Interest

Making use of a small direct methanol fuel cell device (DMFC), used as an analytical sensor, chemometric methods, organic compounds very different from one another, can be determined qualitatively and quantitatively. In this research, the following seven different organic compounds of pharmaceutical...

Descripción completa

Detalles Bibliográficos
Autores principales: Tomassetti, Mauro, Marini, Federico, Angeloni, Riccardo, Castrucci, Mauro, Campanella, Luigi, Di Natale, Corrado
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7374455/
https://www.ncbi.nlm.nih.gov/pubmed/32605007
http://dx.doi.org/10.3390/s20133615
_version_ 1783561703095533568
author Tomassetti, Mauro
Marini, Federico
Angeloni, Riccardo
Castrucci, Mauro
Campanella, Luigi
Di Natale, Corrado
author_facet Tomassetti, Mauro
Marini, Federico
Angeloni, Riccardo
Castrucci, Mauro
Campanella, Luigi
Di Natale, Corrado
author_sort Tomassetti, Mauro
collection PubMed
description Making use of a small direct methanol fuel cell device (DMFC), used as an analytical sensor, chemometric methods, organic compounds very different from one another, can be determined qualitatively and quantitatively. In this research, the following seven different organic compounds of pharmaceutical and biomedical interest, having in common only one –OH group, were considered: chloramphenicol, imipenem, methanol, ethanol, propanol, atropine and cortisone. From a quantitative point of view, the traditional approach, involving the building of individual calibration curves, which allow the quantitative determination of the corresponding organic compounds, even if with different sensitivities, was followed. For the qualitative analysis of each compound, this approach has been much more innovative. In fact, by processing the data from each of the individual response curves, obtained through the fuel cell, using chemometric methods, it is possible to directly identify and recognize each of the seven organic compounds. Since the study is a proof of concept to show the potential of this innovative methodological approach, based on the combination of direct methanol fuel cell with advanced chemometric tools, at this stage, concentration ranges that may not be the ones found in some real situations were investigated. The three methods adopted are all explorative methods with very limited computation costs, which have different characteristics and, therefore, may provide complementary information on the analyzed data. Indeed, while PCA (principal components analysis) provides the most parsimonious summary of the variability observed in the current response matrix, the analysis of the current response behavior was performed by the “slicing” method, in order to transform the current response profiles into numerical matrices, while PARAFAC (Parallel Factor Analysis) allows to obtain a finer deconvolution of the exponential curves. On the other hand, the multiblock nature of “ComDim” (Common Components and Specific Weight Analysis) has been the basis to relate the variability observed in the current response behavior with the parameters of the linear calibrations.
format Online
Article
Text
id pubmed-7374455
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-73744552020-08-05 Direct Catalytic Fuel Cell Device Coupled to Chemometric Methods to Detect Organic Compounds of Pharmaceutical and Biomedical Interest Tomassetti, Mauro Marini, Federico Angeloni, Riccardo Castrucci, Mauro Campanella, Luigi Di Natale, Corrado Sensors (Basel) Article Making use of a small direct methanol fuel cell device (DMFC), used as an analytical sensor, chemometric methods, organic compounds very different from one another, can be determined qualitatively and quantitatively. In this research, the following seven different organic compounds of pharmaceutical and biomedical interest, having in common only one –OH group, were considered: chloramphenicol, imipenem, methanol, ethanol, propanol, atropine and cortisone. From a quantitative point of view, the traditional approach, involving the building of individual calibration curves, which allow the quantitative determination of the corresponding organic compounds, even if with different sensitivities, was followed. For the qualitative analysis of each compound, this approach has been much more innovative. In fact, by processing the data from each of the individual response curves, obtained through the fuel cell, using chemometric methods, it is possible to directly identify and recognize each of the seven organic compounds. Since the study is a proof of concept to show the potential of this innovative methodological approach, based on the combination of direct methanol fuel cell with advanced chemometric tools, at this stage, concentration ranges that may not be the ones found in some real situations were investigated. The three methods adopted are all explorative methods with very limited computation costs, which have different characteristics and, therefore, may provide complementary information on the analyzed data. Indeed, while PCA (principal components analysis) provides the most parsimonious summary of the variability observed in the current response matrix, the analysis of the current response behavior was performed by the “slicing” method, in order to transform the current response profiles into numerical matrices, while PARAFAC (Parallel Factor Analysis) allows to obtain a finer deconvolution of the exponential curves. On the other hand, the multiblock nature of “ComDim” (Common Components and Specific Weight Analysis) has been the basis to relate the variability observed in the current response behavior with the parameters of the linear calibrations. MDPI 2020-06-27 /pmc/articles/PMC7374455/ /pubmed/32605007 http://dx.doi.org/10.3390/s20133615 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Tomassetti, Mauro
Marini, Federico
Angeloni, Riccardo
Castrucci, Mauro
Campanella, Luigi
Di Natale, Corrado
Direct Catalytic Fuel Cell Device Coupled to Chemometric Methods to Detect Organic Compounds of Pharmaceutical and Biomedical Interest
title Direct Catalytic Fuel Cell Device Coupled to Chemometric Methods to Detect Organic Compounds of Pharmaceutical and Biomedical Interest
title_full Direct Catalytic Fuel Cell Device Coupled to Chemometric Methods to Detect Organic Compounds of Pharmaceutical and Biomedical Interest
title_fullStr Direct Catalytic Fuel Cell Device Coupled to Chemometric Methods to Detect Organic Compounds of Pharmaceutical and Biomedical Interest
title_full_unstemmed Direct Catalytic Fuel Cell Device Coupled to Chemometric Methods to Detect Organic Compounds of Pharmaceutical and Biomedical Interest
title_short Direct Catalytic Fuel Cell Device Coupled to Chemometric Methods to Detect Organic Compounds of Pharmaceutical and Biomedical Interest
title_sort direct catalytic fuel cell device coupled to chemometric methods to detect organic compounds of pharmaceutical and biomedical interest
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7374455/
https://www.ncbi.nlm.nih.gov/pubmed/32605007
http://dx.doi.org/10.3390/s20133615
work_keys_str_mv AT tomassettimauro directcatalyticfuelcelldevicecoupledtochemometricmethodstodetectorganiccompoundsofpharmaceuticalandbiomedicalinterest
AT marinifederico directcatalyticfuelcelldevicecoupledtochemometricmethodstodetectorganiccompoundsofpharmaceuticalandbiomedicalinterest
AT angeloniriccardo directcatalyticfuelcelldevicecoupledtochemometricmethodstodetectorganiccompoundsofpharmaceuticalandbiomedicalinterest
AT castruccimauro directcatalyticfuelcelldevicecoupledtochemometricmethodstodetectorganiccompoundsofpharmaceuticalandbiomedicalinterest
AT campanellaluigi directcatalyticfuelcelldevicecoupledtochemometricmethodstodetectorganiccompoundsofpharmaceuticalandbiomedicalinterest
AT dinatalecorrado directcatalyticfuelcelldevicecoupledtochemometricmethodstodetectorganiccompoundsofpharmaceuticalandbiomedicalinterest