Cargando…
Development of Low-Cost AuNP-Based Aptasensors with Truncated Aptamer for Highly Sensitive Detection of 8-Oxo-dG in Urine
[Image: see text] 8-Oxo-7,8-dihydro-2′-deoxyguanosine (8-oxo-dG), an oxidized form of guanosine residues, is a critical biomarker for various cancers. Herein, a sensitive citrate-capped gold nanoparticle-based aptasensor device has been developed for the detection of 8-oxo-dG in urine. We previously...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2020
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7377066/ https://www.ncbi.nlm.nih.gov/pubmed/32715227 http://dx.doi.org/10.1021/acsomega.0c01834 |
_version_ | 1783562150845874176 |
---|---|
author | Matulakul, Piyaporn Vongpramate, Drusawin Kulchat, Sirinan Chompoosor, Apiwat Thanan, Raynoo Sithithaworn, Paiboon Sakonsinsiri, Chadamas Puangmali, Theerapong |
author_facet | Matulakul, Piyaporn Vongpramate, Drusawin Kulchat, Sirinan Chompoosor, Apiwat Thanan, Raynoo Sithithaworn, Paiboon Sakonsinsiri, Chadamas Puangmali, Theerapong |
author_sort | Matulakul, Piyaporn |
collection | PubMed |
description | [Image: see text] 8-Oxo-7,8-dihydro-2′-deoxyguanosine (8-oxo-dG), an oxidized form of guanosine residues, is a critical biomarker for various cancers. Herein, a sensitive citrate-capped gold nanoparticle-based aptasensor device has been developed for the detection of 8-oxo-dG in urine. We previously designed a 38-nt anti-8-oxo-dG-aptamer by a computer simulation and the experimental validation has been performed in the present work. The analytical performance of the 38-nt aptamer from the in silico design was compared with the parent 66-nt aptamer. This assay is based on the principle of salt-induced aggregation of citrate-capped gold nanoparticles. Based on this sensing mechanism, the difference between the absorbance in the presence and absence of 8-oxo-dG at λ = 525 nm (ΔA525) increased linearly as a function of 8-oxo-dG concentrations in the ranges of 10–100 and 15–100 nM for 38-nt and 66-nt aptasensors, respectively. This method can provide detection limits of 6.4 nM for 8-oxo-dG in the 38-nt aptasensor and 13.2 nM in the 66-nt aptasensor. Similar to the 66-nt aptamer, the shortened aptamer, 38-nt long, can provide high sensitivity and selectivity with rapid detection time. In addition, using the 38-nt aptamer as a recognition component in the developed portable low-cost device showed high sensitivity in the detection range of 15–100 nM with a detection limit of 12.9 nM, which is much lower than the threshold value (280 nM) for normal human urine. This easy-to-use device could effectively and economically be utilized for monitoring 8-oxo-dG in real urine samples and potentially serve as a prototype for a commercial device. |
format | Online Article Text |
id | pubmed-7377066 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-73770662020-07-24 Development of Low-Cost AuNP-Based Aptasensors with Truncated Aptamer for Highly Sensitive Detection of 8-Oxo-dG in Urine Matulakul, Piyaporn Vongpramate, Drusawin Kulchat, Sirinan Chompoosor, Apiwat Thanan, Raynoo Sithithaworn, Paiboon Sakonsinsiri, Chadamas Puangmali, Theerapong ACS Omega [Image: see text] 8-Oxo-7,8-dihydro-2′-deoxyguanosine (8-oxo-dG), an oxidized form of guanosine residues, is a critical biomarker for various cancers. Herein, a sensitive citrate-capped gold nanoparticle-based aptasensor device has been developed for the detection of 8-oxo-dG in urine. We previously designed a 38-nt anti-8-oxo-dG-aptamer by a computer simulation and the experimental validation has been performed in the present work. The analytical performance of the 38-nt aptamer from the in silico design was compared with the parent 66-nt aptamer. This assay is based on the principle of salt-induced aggregation of citrate-capped gold nanoparticles. Based on this sensing mechanism, the difference between the absorbance in the presence and absence of 8-oxo-dG at λ = 525 nm (ΔA525) increased linearly as a function of 8-oxo-dG concentrations in the ranges of 10–100 and 15–100 nM for 38-nt and 66-nt aptasensors, respectively. This method can provide detection limits of 6.4 nM for 8-oxo-dG in the 38-nt aptasensor and 13.2 nM in the 66-nt aptasensor. Similar to the 66-nt aptamer, the shortened aptamer, 38-nt long, can provide high sensitivity and selectivity with rapid detection time. In addition, using the 38-nt aptamer as a recognition component in the developed portable low-cost device showed high sensitivity in the detection range of 15–100 nM with a detection limit of 12.9 nM, which is much lower than the threshold value (280 nM) for normal human urine. This easy-to-use device could effectively and economically be utilized for monitoring 8-oxo-dG in real urine samples and potentially serve as a prototype for a commercial device. American Chemical Society 2020-07-08 /pmc/articles/PMC7377066/ /pubmed/32715227 http://dx.doi.org/10.1021/acsomega.0c01834 Text en Copyright © 2020 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes. |
spellingShingle | Matulakul, Piyaporn Vongpramate, Drusawin Kulchat, Sirinan Chompoosor, Apiwat Thanan, Raynoo Sithithaworn, Paiboon Sakonsinsiri, Chadamas Puangmali, Theerapong Development of Low-Cost AuNP-Based Aptasensors with Truncated Aptamer for Highly Sensitive Detection of 8-Oxo-dG in Urine |
title | Development of Low-Cost AuNP-Based Aptasensors with
Truncated Aptamer for Highly Sensitive Detection of 8-Oxo-dG
in Urine |
title_full | Development of Low-Cost AuNP-Based Aptasensors with
Truncated Aptamer for Highly Sensitive Detection of 8-Oxo-dG
in Urine |
title_fullStr | Development of Low-Cost AuNP-Based Aptasensors with
Truncated Aptamer for Highly Sensitive Detection of 8-Oxo-dG
in Urine |
title_full_unstemmed | Development of Low-Cost AuNP-Based Aptasensors with
Truncated Aptamer for Highly Sensitive Detection of 8-Oxo-dG
in Urine |
title_short | Development of Low-Cost AuNP-Based Aptasensors with
Truncated Aptamer for Highly Sensitive Detection of 8-Oxo-dG
in Urine |
title_sort | development of low-cost aunp-based aptasensors with
truncated aptamer for highly sensitive detection of 8-oxo-dg
in urine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7377066/ https://www.ncbi.nlm.nih.gov/pubmed/32715227 http://dx.doi.org/10.1021/acsomega.0c01834 |
work_keys_str_mv | AT matulakulpiyaporn developmentoflowcostaunpbasedaptasensorswithtruncatedaptamerforhighlysensitivedetectionof8oxodginurine AT vongpramatedrusawin developmentoflowcostaunpbasedaptasensorswithtruncatedaptamerforhighlysensitivedetectionof8oxodginurine AT kulchatsirinan developmentoflowcostaunpbasedaptasensorswithtruncatedaptamerforhighlysensitivedetectionof8oxodginurine AT chompoosorapiwat developmentoflowcostaunpbasedaptasensorswithtruncatedaptamerforhighlysensitivedetectionof8oxodginurine AT thananraynoo developmentoflowcostaunpbasedaptasensorswithtruncatedaptamerforhighlysensitivedetectionof8oxodginurine AT sithithawornpaiboon developmentoflowcostaunpbasedaptasensorswithtruncatedaptamerforhighlysensitivedetectionof8oxodginurine AT sakonsinsirichadamas developmentoflowcostaunpbasedaptasensorswithtruncatedaptamerforhighlysensitivedetectionof8oxodginurine AT puangmalitheerapong developmentoflowcostaunpbasedaptasensorswithtruncatedaptamerforhighlysensitivedetectionof8oxodginurine |