Cargando…

Reliability of a musculoskeletal profiling test battery in elite academy soccer players

The study aimed to quantify the measurement error / reliability of a musculoskeletal profiling test battery administered in young, elite academy soccer players, and to examine if the order in which the test battery was administered, and who it was administered by, influenced reliability. Players (n...

Descripción completa

Detalles Bibliográficos
Autores principales: Grazette, Neval, McAllister, Scot, Ong, Chin Wei, Sunderland, Caroline, Nevill, Mary E., Morris, John G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7377398/
https://www.ncbi.nlm.nih.gov/pubmed/32702027
http://dx.doi.org/10.1371/journal.pone.0236341
_version_ 1783562208002703360
author Grazette, Neval
McAllister, Scot
Ong, Chin Wei
Sunderland, Caroline
Nevill, Mary E.
Morris, John G.
author_facet Grazette, Neval
McAllister, Scot
Ong, Chin Wei
Sunderland, Caroline
Nevill, Mary E.
Morris, John G.
author_sort Grazette, Neval
collection PubMed
description The study aimed to quantify the measurement error / reliability of a musculoskeletal profiling test battery administered in young, elite academy soccer players, and to examine if the order in which the test battery was administered, and who it was administered by, influenced reliability. Players (n = 75; age 12–20 years; stature 1.47–1.95 m; body mass 36–89 kg) from U-12 to U-23 age groups were assigned to either: 1) intra-rater-fixed order; 2) intra-rater-non-fixed order; 3) inter-rater-fixed order; or, 4) inter-rater-non-fixed order groups. On two separate occasions separated by 3 to 7 days, 12 raters conducted a musculoskeletal profiling test battery comprising 10 tests (Supine Medial Hip Rotation, Supine Lateral Hip Rotation, Hamstring 90/90, Prone Medial Hip Rotation [degrees]; Combined Elevation, Thoracic Rotation, Weight-Bearing Dorsiflexion, Y-Balance [centimetres]; Beighton, Lumbar Quadrant [categorical]). The measurement error / reliability for tests measured in degrees and centimetres was evaluated using the intraclass correlation (relative reliability), coefficient of variation and ratio limits of agreement (absolute reliability). Intraclass correlations varied from 0.04 (“poor”) to 0.95 (“excellent”), coefficient of variation from 2.9 to 43.4%, and the ratio limits of agreement from 1.058 (*/÷ 1.020) to 2.026 (*/÷ 1.319) for the tests measured in degrees and centimetres. The intraclass correlation, coefficient of variation and ratio limits of agreement were smallest for five out of eight tests measured in degrees and centimetres when the tests were administered in an intra-rater-fixed test order. These findings emphasise that different testing methods, and the administration of a musculoskeletal profiling test battery using a less than optimal design, will influence measurement error and hence test reliability. These observations need to be considered when investigating musculoskeletal function and age, injury, training or asymmetry in young, elite academy soccer players.
format Online
Article
Text
id pubmed-7377398
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-73773982020-08-12 Reliability of a musculoskeletal profiling test battery in elite academy soccer players Grazette, Neval McAllister, Scot Ong, Chin Wei Sunderland, Caroline Nevill, Mary E. Morris, John G. PLoS One Research Article The study aimed to quantify the measurement error / reliability of a musculoskeletal profiling test battery administered in young, elite academy soccer players, and to examine if the order in which the test battery was administered, and who it was administered by, influenced reliability. Players (n = 75; age 12–20 years; stature 1.47–1.95 m; body mass 36–89 kg) from U-12 to U-23 age groups were assigned to either: 1) intra-rater-fixed order; 2) intra-rater-non-fixed order; 3) inter-rater-fixed order; or, 4) inter-rater-non-fixed order groups. On two separate occasions separated by 3 to 7 days, 12 raters conducted a musculoskeletal profiling test battery comprising 10 tests (Supine Medial Hip Rotation, Supine Lateral Hip Rotation, Hamstring 90/90, Prone Medial Hip Rotation [degrees]; Combined Elevation, Thoracic Rotation, Weight-Bearing Dorsiflexion, Y-Balance [centimetres]; Beighton, Lumbar Quadrant [categorical]). The measurement error / reliability for tests measured in degrees and centimetres was evaluated using the intraclass correlation (relative reliability), coefficient of variation and ratio limits of agreement (absolute reliability). Intraclass correlations varied from 0.04 (“poor”) to 0.95 (“excellent”), coefficient of variation from 2.9 to 43.4%, and the ratio limits of agreement from 1.058 (*/÷ 1.020) to 2.026 (*/÷ 1.319) for the tests measured in degrees and centimetres. The intraclass correlation, coefficient of variation and ratio limits of agreement were smallest for five out of eight tests measured in degrees and centimetres when the tests were administered in an intra-rater-fixed test order. These findings emphasise that different testing methods, and the administration of a musculoskeletal profiling test battery using a less than optimal design, will influence measurement error and hence test reliability. These observations need to be considered when investigating musculoskeletal function and age, injury, training or asymmetry in young, elite academy soccer players. Public Library of Science 2020-07-23 /pmc/articles/PMC7377398/ /pubmed/32702027 http://dx.doi.org/10.1371/journal.pone.0236341 Text en © 2020 Grazette et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Grazette, Neval
McAllister, Scot
Ong, Chin Wei
Sunderland, Caroline
Nevill, Mary E.
Morris, John G.
Reliability of a musculoskeletal profiling test battery in elite academy soccer players
title Reliability of a musculoskeletal profiling test battery in elite academy soccer players
title_full Reliability of a musculoskeletal profiling test battery in elite academy soccer players
title_fullStr Reliability of a musculoskeletal profiling test battery in elite academy soccer players
title_full_unstemmed Reliability of a musculoskeletal profiling test battery in elite academy soccer players
title_short Reliability of a musculoskeletal profiling test battery in elite academy soccer players
title_sort reliability of a musculoskeletal profiling test battery in elite academy soccer players
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7377398/
https://www.ncbi.nlm.nih.gov/pubmed/32702027
http://dx.doi.org/10.1371/journal.pone.0236341
work_keys_str_mv AT grazetteneval reliabilityofamusculoskeletalprofilingtestbatteryineliteacademysoccerplayers
AT mcallisterscot reliabilityofamusculoskeletalprofilingtestbatteryineliteacademysoccerplayers
AT ongchinwei reliabilityofamusculoskeletalprofilingtestbatteryineliteacademysoccerplayers
AT sunderlandcaroline reliabilityofamusculoskeletalprofilingtestbatteryineliteacademysoccerplayers
AT nevillmarye reliabilityofamusculoskeletalprofilingtestbatteryineliteacademysoccerplayers
AT morrisjohng reliabilityofamusculoskeletalprofilingtestbatteryineliteacademysoccerplayers