Cargando…

Comparison of direct measurement of intracranial pressures and presumptive clinical and magnetic resonance imaging indicators of intracranial hypertension in dogs with brain tumors

BACKGROUND: Intracranial hypertension (ICH) is often presumptively diagnosed based on clinical or imaging findings. Clinical or imaging surrogates of ICH are not usually validated with reference standard direct intracranial pressure (dICP) recordings. HYPOTHESES: Dogs with brain magnetic resonance i...

Descripción completa

Detalles Bibliográficos
Autores principales: Giannasi, Savannah, Kani, Yukitaka, Hsu, Fang‐Chi, Rossmeisl, John H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7379039/
https://www.ncbi.nlm.nih.gov/pubmed/32415794
http://dx.doi.org/10.1111/jvim.15802
_version_ 1783562554029637632
author Giannasi, Savannah
Kani, Yukitaka
Hsu, Fang‐Chi
Rossmeisl, John H.
author_facet Giannasi, Savannah
Kani, Yukitaka
Hsu, Fang‐Chi
Rossmeisl, John H.
author_sort Giannasi, Savannah
collection PubMed
description BACKGROUND: Intracranial hypertension (ICH) is often presumptively diagnosed based on clinical or imaging findings. Clinical or imaging surrogates of ICH are not usually validated with reference standard direct intracranial pressure (dICP) recordings. HYPOTHESES: Dogs with brain magnetic resonance imaging (MRI) or clinical features of presumed ICH would have higher dICP than dogs lacking those features. ANIMALS: Twenty dogs with gliomas and 3 normal controls. METHODS: Prospective, convenience study. Dogs were presumptively categorized with normal ICP or ICH from scores generated from described clinical and brain MRI indicators of ICH. dICP was recorded in anesthetized dogs using an intraparenchymal microsensor and compared between groups. RESULTS: dICP was not different between control (10.4 ± 2.1 mm Hg) and dogs with glioma (15.6 ± 8.3 mm Hg), or between dogs in clinically predicted ICP groups. Compared with dogs with MRI‐predicted normal ICP, MRI‐predicted ICH dogs had higher dICP (10.3 ± 4.1 versus 19.2 ± 7.9 mm Hg, P = .004), larger tumors (1.45 ± 1.2 versus 5.71 ± 3.03 cm(3), P = .0004), larger optic nerve sheath diameters, and 14/14 (100%) displayed structural anatomical shifts on MRI. At a dICP threshold of 15 mm Hg, the sensitivity of MRI for predicting ICH was 90% and the specificity 69%. CONCLUSIONS AND CLINICAL RELEVANCE: dICP measurements are feasible in dogs with brain tumors. MRI features including brain herniations, mass effect, and optic nerve size aid in the identification of dogs with ICH. Clinical estimation of ICP did not discriminate between dogs with and without ICH.
format Online
Article
Text
id pubmed-7379039
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-73790392020-07-27 Comparison of direct measurement of intracranial pressures and presumptive clinical and magnetic resonance imaging indicators of intracranial hypertension in dogs with brain tumors Giannasi, Savannah Kani, Yukitaka Hsu, Fang‐Chi Rossmeisl, John H. J Vet Intern Med SMALL ANIMAL BACKGROUND: Intracranial hypertension (ICH) is often presumptively diagnosed based on clinical or imaging findings. Clinical or imaging surrogates of ICH are not usually validated with reference standard direct intracranial pressure (dICP) recordings. HYPOTHESES: Dogs with brain magnetic resonance imaging (MRI) or clinical features of presumed ICH would have higher dICP than dogs lacking those features. ANIMALS: Twenty dogs with gliomas and 3 normal controls. METHODS: Prospective, convenience study. Dogs were presumptively categorized with normal ICP or ICH from scores generated from described clinical and brain MRI indicators of ICH. dICP was recorded in anesthetized dogs using an intraparenchymal microsensor and compared between groups. RESULTS: dICP was not different between control (10.4 ± 2.1 mm Hg) and dogs with glioma (15.6 ± 8.3 mm Hg), or between dogs in clinically predicted ICP groups. Compared with dogs with MRI‐predicted normal ICP, MRI‐predicted ICH dogs had higher dICP (10.3 ± 4.1 versus 19.2 ± 7.9 mm Hg, P = .004), larger tumors (1.45 ± 1.2 versus 5.71 ± 3.03 cm(3), P = .0004), larger optic nerve sheath diameters, and 14/14 (100%) displayed structural anatomical shifts on MRI. At a dICP threshold of 15 mm Hg, the sensitivity of MRI for predicting ICH was 90% and the specificity 69%. CONCLUSIONS AND CLINICAL RELEVANCE: dICP measurements are feasible in dogs with brain tumors. MRI features including brain herniations, mass effect, and optic nerve size aid in the identification of dogs with ICH. Clinical estimation of ICP did not discriminate between dogs with and without ICH. John Wiley & Sons, Inc. 2020-05-16 2020-07 /pmc/articles/PMC7379039/ /pubmed/32415794 http://dx.doi.org/10.1111/jvim.15802 Text en © 2020 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle SMALL ANIMAL
Giannasi, Savannah
Kani, Yukitaka
Hsu, Fang‐Chi
Rossmeisl, John H.
Comparison of direct measurement of intracranial pressures and presumptive clinical and magnetic resonance imaging indicators of intracranial hypertension in dogs with brain tumors
title Comparison of direct measurement of intracranial pressures and presumptive clinical and magnetic resonance imaging indicators of intracranial hypertension in dogs with brain tumors
title_full Comparison of direct measurement of intracranial pressures and presumptive clinical and magnetic resonance imaging indicators of intracranial hypertension in dogs with brain tumors
title_fullStr Comparison of direct measurement of intracranial pressures and presumptive clinical and magnetic resonance imaging indicators of intracranial hypertension in dogs with brain tumors
title_full_unstemmed Comparison of direct measurement of intracranial pressures and presumptive clinical and magnetic resonance imaging indicators of intracranial hypertension in dogs with brain tumors
title_short Comparison of direct measurement of intracranial pressures and presumptive clinical and magnetic resonance imaging indicators of intracranial hypertension in dogs with brain tumors
title_sort comparison of direct measurement of intracranial pressures and presumptive clinical and magnetic resonance imaging indicators of intracranial hypertension in dogs with brain tumors
topic SMALL ANIMAL
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7379039/
https://www.ncbi.nlm.nih.gov/pubmed/32415794
http://dx.doi.org/10.1111/jvim.15802
work_keys_str_mv AT giannasisavannah comparisonofdirectmeasurementofintracranialpressuresandpresumptiveclinicalandmagneticresonanceimagingindicatorsofintracranialhypertensionindogswithbraintumors
AT kaniyukitaka comparisonofdirectmeasurementofintracranialpressuresandpresumptiveclinicalandmagneticresonanceimagingindicatorsofintracranialhypertensionindogswithbraintumors
AT hsufangchi comparisonofdirectmeasurementofintracranialpressuresandpresumptiveclinicalandmagneticresonanceimagingindicatorsofintracranialhypertensionindogswithbraintumors
AT rossmeisljohnh comparisonofdirectmeasurementofintracranialpressuresandpresumptiveclinicalandmagneticresonanceimagingindicatorsofintracranialhypertensionindogswithbraintumors