Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients

BACKGROUND/AIM: FloTrac/Vigileo is a noncalibrated arterial pressure waveform analysis for cardiac index (CI) monitoring. The aim of our study was to compare the CI measured by the 4th generation of FloTrac with PiCCO in septic shock patients. MATERIALS AND METHODS: We simultaneously measured the CI...

Descripción completa

Detalles Bibliográficos
Autores principales: KHWANNIMIT, Bodin, JOMSURIYA, Rattina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Scientific and Technological Research Council of Turkey 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7379425/
https://www.ncbi.nlm.nih.gov/pubmed/32336075
http://dx.doi.org/10.3906/sag-1909-58
_version_ 1783562636757041152
author KHWANNIMIT, Bodin
JOMSURIYA, Rattina
author_facet KHWANNIMIT, Bodin
JOMSURIYA, Rattina
author_sort KHWANNIMIT, Bodin
collection PubMed
description BACKGROUND/AIM: FloTrac/Vigileo is a noncalibrated arterial pressure waveform analysis for cardiac index (CI) monitoring. The aim of our study was to compare the CI measured by the 4th generation of FloTrac with PiCCO in septic shock patients. MATERIALS AND METHODS: We simultaneously measured the CI using FloTrac (CIv) and compared it with the CI derived from transpulmonary thermodilution (CItd) as well as the pulse contour-derived CI using PiCCO (CIp). RESULTS: Thirty-one septic shock patients were included. The CIv correlated with CItd (r = 0.62, P < 0.0001). The Bland-Altman analysis showed a bias of 0.14, and the limits of agreement were –1.62–1.91 L/min/m2 with a percentage error of 47.4%. However, the concordance rate between CIv and CItd was 93.6%. The comparison of CIv with CIp (n = 352 paired measurements) revealed a bias of -0.16, and the limits of agreement were –1.45–1.79 L/min/m2 with a percentage error of 44.8%. The overall correlation coefficient between CIv and CIp was 0.63 (P < 0.0001), and the concordance rate was 85.4%. CONCLUSION: The 4th generation of FloTrac has not acceptable agreement to assess CI; however, it has the ability to tracked changes of CI, when compared with the transpulmonary thermodilution method by PiCCO.
format Online
Article
Text
id pubmed-7379425
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Scientific and Technological Research Council of Turkey
record_format MEDLINE/PubMed
spelling pubmed-73794252020-07-27 Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients KHWANNIMIT, Bodin JOMSURIYA, Rattina Turk J Med Sci Article BACKGROUND/AIM: FloTrac/Vigileo is a noncalibrated arterial pressure waveform analysis for cardiac index (CI) monitoring. The aim of our study was to compare the CI measured by the 4th generation of FloTrac with PiCCO in septic shock patients. MATERIALS AND METHODS: We simultaneously measured the CI using FloTrac (CIv) and compared it with the CI derived from transpulmonary thermodilution (CItd) as well as the pulse contour-derived CI using PiCCO (CIp). RESULTS: Thirty-one septic shock patients were included. The CIv correlated with CItd (r = 0.62, P < 0.0001). The Bland-Altman analysis showed a bias of 0.14, and the limits of agreement were –1.62–1.91 L/min/m2 with a percentage error of 47.4%. However, the concordance rate between CIv and CItd was 93.6%. The comparison of CIv with CIp (n = 352 paired measurements) revealed a bias of -0.16, and the limits of agreement were –1.45–1.79 L/min/m2 with a percentage error of 44.8%. The overall correlation coefficient between CIv and CIp was 0.63 (P < 0.0001), and the concordance rate was 85.4%. CONCLUSION: The 4th generation of FloTrac has not acceptable agreement to assess CI; however, it has the ability to tracked changes of CI, when compared with the transpulmonary thermodilution method by PiCCO. The Scientific and Technological Research Council of Turkey 2020-06-23 /pmc/articles/PMC7379425/ /pubmed/32336075 http://dx.doi.org/10.3906/sag-1909-58 Text en Copyright © 2020 The Author(s) This article is distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use and redistribution provided that the original author and source are credited.
spellingShingle Article
KHWANNIMIT, Bodin
JOMSURIYA, Rattina
Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients
title Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients
title_full Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients
title_fullStr Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients
title_full_unstemmed Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients
title_short Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients
title_sort comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of flotrac with the picco device in septic shock patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7379425/
https://www.ncbi.nlm.nih.gov/pubmed/32336075
http://dx.doi.org/10.3906/sag-1909-58
work_keys_str_mv AT khwannimitbodin comparisontheaccuracyandtrendingabilityofcardiacindexmeasuredbythefourthgenerationofflotracwiththepiccodeviceinsepticshockpatients
AT jomsuriyarattina comparisontheaccuracyandtrendingabilityofcardiacindexmeasuredbythefourthgenerationofflotracwiththepiccodeviceinsepticshockpatients