Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients
BACKGROUND/AIM: FloTrac/Vigileo is a noncalibrated arterial pressure waveform analysis for cardiac index (CI) monitoring. The aim of our study was to compare the CI measured by the 4th generation of FloTrac with PiCCO in septic shock patients. MATERIALS AND METHODS: We simultaneously measured the CI...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Scientific and Technological Research Council of Turkey
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7379425/ https://www.ncbi.nlm.nih.gov/pubmed/32336075 http://dx.doi.org/10.3906/sag-1909-58 |
_version_ | 1783562636757041152 |
---|---|
author | KHWANNIMIT, Bodin JOMSURIYA, Rattina |
author_facet | KHWANNIMIT, Bodin JOMSURIYA, Rattina |
author_sort | KHWANNIMIT, Bodin |
collection | PubMed |
description | BACKGROUND/AIM: FloTrac/Vigileo is a noncalibrated arterial pressure waveform analysis for cardiac index (CI) monitoring. The aim of our study was to compare the CI measured by the 4th generation of FloTrac with PiCCO in septic shock patients. MATERIALS AND METHODS: We simultaneously measured the CI using FloTrac (CIv) and compared it with the CI derived from transpulmonary thermodilution (CItd) as well as the pulse contour-derived CI using PiCCO (CIp). RESULTS: Thirty-one septic shock patients were included. The CIv correlated with CItd (r = 0.62, P < 0.0001). The Bland-Altman analysis showed a bias of 0.14, and the limits of agreement were –1.62–1.91 L/min/m2 with a percentage error of 47.4%. However, the concordance rate between CIv and CItd was 93.6%. The comparison of CIv with CIp (n = 352 paired measurements) revealed a bias of -0.16, and the limits of agreement were –1.45–1.79 L/min/m2 with a percentage error of 44.8%. The overall correlation coefficient between CIv and CIp was 0.63 (P < 0.0001), and the concordance rate was 85.4%. CONCLUSION: The 4th generation of FloTrac has not acceptable agreement to assess CI; however, it has the ability to tracked changes of CI, when compared with the transpulmonary thermodilution method by PiCCO. |
format | Online Article Text |
id | pubmed-7379425 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Scientific and Technological Research Council of Turkey |
record_format | MEDLINE/PubMed |
spelling | pubmed-73794252020-07-27 Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients KHWANNIMIT, Bodin JOMSURIYA, Rattina Turk J Med Sci Article BACKGROUND/AIM: FloTrac/Vigileo is a noncalibrated arterial pressure waveform analysis for cardiac index (CI) monitoring. The aim of our study was to compare the CI measured by the 4th generation of FloTrac with PiCCO in septic shock patients. MATERIALS AND METHODS: We simultaneously measured the CI using FloTrac (CIv) and compared it with the CI derived from transpulmonary thermodilution (CItd) as well as the pulse contour-derived CI using PiCCO (CIp). RESULTS: Thirty-one septic shock patients were included. The CIv correlated with CItd (r = 0.62, P < 0.0001). The Bland-Altman analysis showed a bias of 0.14, and the limits of agreement were –1.62–1.91 L/min/m2 with a percentage error of 47.4%. However, the concordance rate between CIv and CItd was 93.6%. The comparison of CIv with CIp (n = 352 paired measurements) revealed a bias of -0.16, and the limits of agreement were –1.45–1.79 L/min/m2 with a percentage error of 44.8%. The overall correlation coefficient between CIv and CIp was 0.63 (P < 0.0001), and the concordance rate was 85.4%. CONCLUSION: The 4th generation of FloTrac has not acceptable agreement to assess CI; however, it has the ability to tracked changes of CI, when compared with the transpulmonary thermodilution method by PiCCO. The Scientific and Technological Research Council of Turkey 2020-06-23 /pmc/articles/PMC7379425/ /pubmed/32336075 http://dx.doi.org/10.3906/sag-1909-58 Text en Copyright © 2020 The Author(s) This article is distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use and redistribution provided that the original author and source are credited. |
spellingShingle | Article KHWANNIMIT, Bodin JOMSURIYA, Rattina Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients |
title | Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients |
title_full | Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients |
title_fullStr | Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients |
title_full_unstemmed | Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients |
title_short | Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients |
title_sort | comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of flotrac with the picco device in septic shock patients |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7379425/ https://www.ncbi.nlm.nih.gov/pubmed/32336075 http://dx.doi.org/10.3906/sag-1909-58 |
work_keys_str_mv | AT khwannimitbodin comparisontheaccuracyandtrendingabilityofcardiacindexmeasuredbythefourthgenerationofflotracwiththepiccodeviceinsepticshockpatients AT jomsuriyarattina comparisontheaccuracyandtrendingabilityofcardiacindexmeasuredbythefourthgenerationofflotracwiththepiccodeviceinsepticshockpatients |