Cargando…

Factors related to difficult self‐expandable metallic stent placement for malignant colonic obstruction: A post‐hoc analysis of a multicenter study across Japan

BACKGROUND AND AIM: Colorectal cancer patients often present with large bowel obstruction. Elective placement of a self‐expandable metallic stent (SEMS) can relieve obstruction, but can be challenging. Previous studies have compared cases by outcomes only, but the present study investigated successf...

Descripción completa

Detalles Bibliográficos
Autores principales: Kuwai, Toshio, Yamaguchi, Toshiki, Imagawa, Hiroki, Yoshida, Shuntaro, Isayama, Hiroyuki, Matsuzawa, Takeaki, Yamada, Tomonori, Saito, Shuji, Shimada, Mamoru, Hirata, Nobuto, Sasaki, Takashi, Koizumi, Koichi, Maetani, Iruru, Saida, Yoshihisa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7379649/
https://www.ncbi.nlm.nih.gov/pubmed/30113095
http://dx.doi.org/10.1111/den.13260
_version_ 1783562688939425792
author Kuwai, Toshio
Yamaguchi, Toshiki
Imagawa, Hiroki
Yoshida, Shuntaro
Isayama, Hiroyuki
Matsuzawa, Takeaki
Yamada, Tomonori
Saito, Shuji
Shimada, Mamoru
Hirata, Nobuto
Sasaki, Takashi
Koizumi, Koichi
Maetani, Iruru
Saida, Yoshihisa
author_facet Kuwai, Toshio
Yamaguchi, Toshiki
Imagawa, Hiroki
Yoshida, Shuntaro
Isayama, Hiroyuki
Matsuzawa, Takeaki
Yamada, Tomonori
Saito, Shuji
Shimada, Mamoru
Hirata, Nobuto
Sasaki, Takashi
Koizumi, Koichi
Maetani, Iruru
Saida, Yoshihisa
author_sort Kuwai, Toshio
collection PubMed
description BACKGROUND AND AIM: Colorectal cancer patients often present with large bowel obstruction. Elective placement of a self‐expandable metallic stent (SEMS) can relieve obstruction, but can be challenging. Previous studies have compared cases by outcomes only, but the present study investigated successful cases only to identify factors related to prolonged and difficult SEMS placement in patients with malignant colonic obstruction. METHODS: A post‐hoc analysis of a multicenter clinical trial conducted between March 2012 and October 2013 at 46 facilities across Japan (UMIN000007953) was carried out; 511 patients who required SEMS placement for acute colorectal obstruction or symptomatic stricture secondary to malignant neoplasm were enrolled. Technical success rates and procedure times were recorded. Clinical and interventional parameters were investigated for their potential effect on procedure time by univariate and multivariate analyses. RESULTS: Technical success rate of SEMS placement was 98%. Median procedure time was 30 (range, 4–170) min. In 27% of patients, procedure time exceeded 45 min, indicating technically difficult placement. Multivariate analyses showed significant associations between technically difficult placement and a ColoRectal Obstruction Scoring System (CROSS) score of 0 before SEMS placement (odds ratio [OR], 1.6; P < 0.05), tumor site in the right colon (OR, 2.5; P < 0.0001), stricture length ≥5 cm (OR, 2.2; P < 0.001), peritoneal carcinomatosis (OR, 1.7; P < 0.05), and multiple SEMS placement (OR, 8.0; P < 0.01). CONCLUSION: Clinicians must anticipate technical challenges in cases with peritoneal carcinomatosis, a CROSS score of 0, or expansive strictures; such cases require experienced clinicians to carry out SEMS placement.
format Online
Article
Text
id pubmed-7379649
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-73796492020-07-24 Factors related to difficult self‐expandable metallic stent placement for malignant colonic obstruction: A post‐hoc analysis of a multicenter study across Japan Kuwai, Toshio Yamaguchi, Toshiki Imagawa, Hiroki Yoshida, Shuntaro Isayama, Hiroyuki Matsuzawa, Takeaki Yamada, Tomonori Saito, Shuji Shimada, Mamoru Hirata, Nobuto Sasaki, Takashi Koizumi, Koichi Maetani, Iruru Saida, Yoshihisa Dig Endosc Original Articles BACKGROUND AND AIM: Colorectal cancer patients often present with large bowel obstruction. Elective placement of a self‐expandable metallic stent (SEMS) can relieve obstruction, but can be challenging. Previous studies have compared cases by outcomes only, but the present study investigated successful cases only to identify factors related to prolonged and difficult SEMS placement in patients with malignant colonic obstruction. METHODS: A post‐hoc analysis of a multicenter clinical trial conducted between March 2012 and October 2013 at 46 facilities across Japan (UMIN000007953) was carried out; 511 patients who required SEMS placement for acute colorectal obstruction or symptomatic stricture secondary to malignant neoplasm were enrolled. Technical success rates and procedure times were recorded. Clinical and interventional parameters were investigated for their potential effect on procedure time by univariate and multivariate analyses. RESULTS: Technical success rate of SEMS placement was 98%. Median procedure time was 30 (range, 4–170) min. In 27% of patients, procedure time exceeded 45 min, indicating technically difficult placement. Multivariate analyses showed significant associations between technically difficult placement and a ColoRectal Obstruction Scoring System (CROSS) score of 0 before SEMS placement (odds ratio [OR], 1.6; P < 0.05), tumor site in the right colon (OR, 2.5; P < 0.0001), stricture length ≥5 cm (OR, 2.2; P < 0.001), peritoneal carcinomatosis (OR, 1.7; P < 0.05), and multiple SEMS placement (OR, 8.0; P < 0.01). CONCLUSION: Clinicians must anticipate technical challenges in cases with peritoneal carcinomatosis, a CROSS score of 0, or expansive strictures; such cases require experienced clinicians to carry out SEMS placement. John Wiley and Sons Inc. 2018-09-03 2019-01 /pmc/articles/PMC7379649/ /pubmed/30113095 http://dx.doi.org/10.1111/den.13260 Text en © 2018 The Authors. Digestive Endoscopy published by John Wiley & Sons Australia, Ltd on behalf of Japan Gastroenterological Endoscopy Society. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Kuwai, Toshio
Yamaguchi, Toshiki
Imagawa, Hiroki
Yoshida, Shuntaro
Isayama, Hiroyuki
Matsuzawa, Takeaki
Yamada, Tomonori
Saito, Shuji
Shimada, Mamoru
Hirata, Nobuto
Sasaki, Takashi
Koizumi, Koichi
Maetani, Iruru
Saida, Yoshihisa
Factors related to difficult self‐expandable metallic stent placement for malignant colonic obstruction: A post‐hoc analysis of a multicenter study across Japan
title Factors related to difficult self‐expandable metallic stent placement for malignant colonic obstruction: A post‐hoc analysis of a multicenter study across Japan
title_full Factors related to difficult self‐expandable metallic stent placement for malignant colonic obstruction: A post‐hoc analysis of a multicenter study across Japan
title_fullStr Factors related to difficult self‐expandable metallic stent placement for malignant colonic obstruction: A post‐hoc analysis of a multicenter study across Japan
title_full_unstemmed Factors related to difficult self‐expandable metallic stent placement for malignant colonic obstruction: A post‐hoc analysis of a multicenter study across Japan
title_short Factors related to difficult self‐expandable metallic stent placement for malignant colonic obstruction: A post‐hoc analysis of a multicenter study across Japan
title_sort factors related to difficult self‐expandable metallic stent placement for malignant colonic obstruction: a post‐hoc analysis of a multicenter study across japan
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7379649/
https://www.ncbi.nlm.nih.gov/pubmed/30113095
http://dx.doi.org/10.1111/den.13260
work_keys_str_mv AT kuwaitoshio factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan
AT yamaguchitoshiki factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan
AT imagawahiroki factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan
AT yoshidashuntaro factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan
AT isayamahiroyuki factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan
AT matsuzawatakeaki factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan
AT yamadatomonori factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan
AT saitoshuji factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan
AT shimadamamoru factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan
AT hiratanobuto factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan
AT sasakitakashi factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan
AT koizumikoichi factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan
AT maetaniiruru factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan
AT saidayoshihisa factorsrelatedtodifficultselfexpandablemetallicstentplacementformalignantcolonicobstructionaposthocanalysisofamulticenterstudyacrossjapan