Cargando…
Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest
BACKGROUND: Reusable suction-cup electrodes are used for recording a 12-lead electrocardiogram (ECG) in resource-limited settings. These electrodes may easily detach if those are attached on a hirsute chest. Additionally, the suction pressure may cause erythema and pain. AIM: The aim of this study w...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7380826/ https://www.ncbi.nlm.nih.gov/pubmed/32754501 http://dx.doi.org/10.4103/jfmpc.jfmpc_292_20 |
_version_ | 1783562919959592960 |
---|---|
author | Mondal, Himel Chattopadhyay, Tanmoy Mondal, Shaikat Das, Debasish Biri, Sairavi Kiran |
author_facet | Mondal, Himel Chattopadhyay, Tanmoy Mondal, Shaikat Das, Debasish Biri, Sairavi Kiran |
author_sort | Mondal, Himel |
collection | PubMed |
description | BACKGROUND: Reusable suction-cup electrodes are used for recording a 12-lead electrocardiogram (ECG) in resource-limited settings. These electrodes may easily detach if those are attached on a hirsute chest. Additionally, the suction pressure may cause erythema and pain. AIM: The aim of this study was to develop a low-cost strap for holding the suction-cup-based precordial electrodes and to test its applicability to the recording of ECG. MATERIALS AND METHODS: A scrap rubber tube was cut in size so that it can cover all the precordial electrode positions. Slit openings (electrodes can be inserted through these opening) were made on this rubber strap. A cloth and a hook-and-loop fastener were used to make an adjustable fastener. ECG was recorded first on 16 non-hairy males with electrodes placed on the chest with the strap and then with electrodes attached by suction. After that, ECG was recorded on 16 males with hirsute chest first with the electrodes placed with the help of the strap and then with suction (without strap) on the shaved chest. RESULTS: The outcome of this study is a low-cost ECG chest strap for a hirsute chest. Both the negative and positive QRS voltages in six precordial leads recorded with electrodes placed with the strap were similar to that of suction-attached electrodes in both non-hairy and hirsute chest. CONCLUSION: Developed rubber chest strap can be made with minimal cost and expertise in any resource-limited settings. This would help in recording the ECG of a patient with a hirsute chest. This prototype strap has scope for further improvement. |
format | Online Article Text |
id | pubmed-7380826 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-73808262020-08-03 Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest Mondal, Himel Chattopadhyay, Tanmoy Mondal, Shaikat Das, Debasish Biri, Sairavi Kiran J Family Med Prim Care Original Article BACKGROUND: Reusable suction-cup electrodes are used for recording a 12-lead electrocardiogram (ECG) in resource-limited settings. These electrodes may easily detach if those are attached on a hirsute chest. Additionally, the suction pressure may cause erythema and pain. AIM: The aim of this study was to develop a low-cost strap for holding the suction-cup-based precordial electrodes and to test its applicability to the recording of ECG. MATERIALS AND METHODS: A scrap rubber tube was cut in size so that it can cover all the precordial electrode positions. Slit openings (electrodes can be inserted through these opening) were made on this rubber strap. A cloth and a hook-and-loop fastener were used to make an adjustable fastener. ECG was recorded first on 16 non-hairy males with electrodes placed on the chest with the strap and then with electrodes attached by suction. After that, ECG was recorded on 16 males with hirsute chest first with the electrodes placed with the help of the strap and then with suction (without strap) on the shaved chest. RESULTS: The outcome of this study is a low-cost ECG chest strap for a hirsute chest. Both the negative and positive QRS voltages in six precordial leads recorded with electrodes placed with the strap were similar to that of suction-attached electrodes in both non-hairy and hirsute chest. CONCLUSION: Developed rubber chest strap can be made with minimal cost and expertise in any resource-limited settings. This would help in recording the ECG of a patient with a hirsute chest. This prototype strap has scope for further improvement. Wolters Kluwer - Medknow 2020-05-31 /pmc/articles/PMC7380826/ /pubmed/32754501 http://dx.doi.org/10.4103/jfmpc.jfmpc_292_20 Text en Copyright: © 2020 Journal of Family Medicine and Primary Care http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Mondal, Himel Chattopadhyay, Tanmoy Mondal, Shaikat Das, Debasish Biri, Sairavi Kiran Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest |
title | Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest |
title_full | Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest |
title_fullStr | Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest |
title_full_unstemmed | Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest |
title_short | Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest |
title_sort | fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7380826/ https://www.ncbi.nlm.nih.gov/pubmed/32754501 http://dx.doi.org/10.4103/jfmpc.jfmpc_292_20 |
work_keys_str_mv | AT mondalhimel fabricationofalowcoststrapforholdingprecordialelectrodesonthehirsutechest AT chattopadhyaytanmoy fabricationofalowcoststrapforholdingprecordialelectrodesonthehirsutechest AT mondalshaikat fabricationofalowcoststrapforholdingprecordialelectrodesonthehirsutechest AT dasdebasish fabricationofalowcoststrapforholdingprecordialelectrodesonthehirsutechest AT birisairavikiran fabricationofalowcoststrapforholdingprecordialelectrodesonthehirsutechest |