Cargando…

Pre-hospital One-Hour Troponin in a Low-Prevalence Population of Acute Coronary Syndrome: OUT-ACS study

OBJECTIVE: The European Society of Cardiology 0/1-hour algorithm for high-sensitivity cardiac troponin T (hs-cTnT) has demonstrated high rule-out safety in large hospital validation cohorts. We aimed to validate the algorithm in a primary care setting, where patients have a lower pretest probability...

Descripción completa

Detalles Bibliográficos
Autores principales: Johannessen, Tonje R, Vallersnes, Odd Martin, Halvorsen, Sigrun, Larstorp, Anne Cecilie K., Mdala, Ibrahimu, Atar, Dan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7380862/
https://www.ncbi.nlm.nih.gov/pubmed/32719074
http://dx.doi.org/10.1136/openhrt-2020-001296
Descripción
Sumario:OBJECTIVE: The European Society of Cardiology 0/1-hour algorithm for high-sensitivity cardiac troponin T (hs-cTnT) has demonstrated high rule-out safety in large hospital validation cohorts. We aimed to validate the algorithm in a primary care setting, where patients have a lower pretest probability for acute coronary syndrome. METHODS: This prospective, observational, diagnostic study included patients with acute non-specific chest pain admitted to a primary care emergency clinic in Oslo, Norway, from November 2016 to October 2018. hs-cTnT was measured after 0, 1 and 4 hours. The primary outcome measure was the diagnostic performance of the 0/1-hour algorithm, the 90-day incidence of AMI or all-cause death the secondary. RESULTS: Among 1711 included patients, 61 (3.6%) were diagnosed with AMI. By applying the algorithm, 1311 (76.6%) patients were assigned to the rule-out group. The negative predictive value was 99.9% (95% CI 99.5% to 100.0%), the sensitivity and specificity 98.4% (91.2–100.0) and 79.4% (77.4–81.3), respectively. Sixty-six (3.9%) patients were triaged towards rule-in, where 45 were diagnosed with AMI. The corresponding positive predictive value was 68.2% (58.3–76.7), sensitivity 73.8% (60.9–84.2), and specificity 98.7% (98.1–99.2). Among 334 (19.5%) patients assigned to the observation group in need of further tests, 15 patients had an AMI. The following 90 days, five new patients experienced an AMI and nine patients died, with a low incidence in the rule-out group (0.3%). CONCLUSION: The 0/1-hour algorithm for hs-cTnT seems safe, efficient and applicable for an accelerated assessment of patients with non-specific chest pain in a primary care emergency setting. TRIAL REGISTRATION NUMBER: NCT02983123.