Personalized Fluoroscopic Angles in Watchman™ Left Atrial Appendage Closure Landing Zone Assessment: A Three-Dimensional Printed Simulation Study

Background Atrial fibrillation causes ischemic stroke when thrombi dislodge from a cardiac outpouching, the left atrial appendage (LAA), and embolize to the brain. LAA occlusion with the Watchman™ device (Boston Scientific Corporation, MA, USA), which prevents stroke, requires accurate LAA measureme...

Descripción completa

Detalles Bibliográficos
Autores principales: Shee, Vikram, He, Liwei, Liu, Shenrong, Huang, Xingfu, Chen, Yanyu, Xie, Liangzhen, Deng, Xiaojiang, Peng, Jian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7381882/
https://www.ncbi.nlm.nih.gov/pubmed/32724734
http://dx.doi.org/10.7759/cureus.8783
_version_ 1783563140041015296
author Shee, Vikram
He, Liwei
Liu, Shenrong
Huang, Xingfu
Chen, Yanyu
Xie, Liangzhen
Deng, Xiaojiang
Peng, Jian
author_facet Shee, Vikram
He, Liwei
Liu, Shenrong
Huang, Xingfu
Chen, Yanyu
Xie, Liangzhen
Deng, Xiaojiang
Peng, Jian
author_sort Shee, Vikram
collection PubMed
description Background Atrial fibrillation causes ischemic stroke when thrombi dislodge from a cardiac outpouching, the left atrial appendage (LAA), and embolize to the brain. LAA occlusion with the Watchman™ device (Boston Scientific Corporation, MA, USA), which prevents stroke, requires accurate LAA measurements for device sizing. We explore whether standard fluoroscopic LAA measurements improve when obtained at CT-derived viewing angles personalized to LAA anatomy while concurrently referring to three-dimensional (3D) CT. Methods Left atrial 3D reconstructions created from contrast CT (n=28) were analysed to identify personalized viewing angles wherein LAA dimensions (LAA maximum landing zone diameter and LAA length) were best observed. The 3D-CT reconstructions were then 3D printed with stands. Fluoroscopy of anatomically oriented models in the catheter lab simulated LAA angiography. Fluoroscopic images were acquired at standard (caudal 20˚/right anterior oblique 30˚) and personalized viewing angles. Repeated measurements of LAA dimensions were taken from CT (Control), fluoroscopy at standard angles (Standard), personalized angles (Blinded), and personalized angles while concurrently referring to 3D CT (Referred). Results Control measurements correlated and agreed better with Referred and Blinded measurements than with Standard measurements (diameter correlation and agreement: Control/Standard r=.554, limits of agreement [LOAs]=6.83/-5.91; Control/Blinded r=.641, LOA =5.67/-5.54; Control/Referred r=.741, LOA=4.69/-4.14; length correlation and agreement: Control/Standard r(s)=.829, LOA=9.61/-3.02; Control/Blinded r(s)=0.789, LOA=7.13/-4.94; Control/Referred r(s)=.907, LOA=4.84/-4.13). Personalized angles resulted in hypothetical device size predictions more consistent with Control (device size correlation: Control/Standard r(s)=.698, Control/Blinded r(s)=.731, Control/Referred r(s)=.893, P<0.001). False ineligibility rates were Standard=6/28, Blinded=6/28, and Referred=2/28. Conclusion This simulation suggests that personalized fluoroscopic viewing angles with in-procedural reference to 3D CT may improve the accuracy of LAA maximum landing zone diameter and length measurements at the Watchman landing zone. This improvement may result in more consistent device size selection and procedural eligibility assessment. Further clinical research on these interventions is merited.
format Online
Article
Text
id pubmed-7381882
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-73818822020-07-27 Personalized Fluoroscopic Angles in Watchman™ Left Atrial Appendage Closure Landing Zone Assessment: A Three-Dimensional Printed Simulation Study Shee, Vikram He, Liwei Liu, Shenrong Huang, Xingfu Chen, Yanyu Xie, Liangzhen Deng, Xiaojiang Peng, Jian Cureus Cardiology Background Atrial fibrillation causes ischemic stroke when thrombi dislodge from a cardiac outpouching, the left atrial appendage (LAA), and embolize to the brain. LAA occlusion with the Watchman™ device (Boston Scientific Corporation, MA, USA), which prevents stroke, requires accurate LAA measurements for device sizing. We explore whether standard fluoroscopic LAA measurements improve when obtained at CT-derived viewing angles personalized to LAA anatomy while concurrently referring to three-dimensional (3D) CT. Methods Left atrial 3D reconstructions created from contrast CT (n=28) were analysed to identify personalized viewing angles wherein LAA dimensions (LAA maximum landing zone diameter and LAA length) were best observed. The 3D-CT reconstructions were then 3D printed with stands. Fluoroscopy of anatomically oriented models in the catheter lab simulated LAA angiography. Fluoroscopic images were acquired at standard (caudal 20˚/right anterior oblique 30˚) and personalized viewing angles. Repeated measurements of LAA dimensions were taken from CT (Control), fluoroscopy at standard angles (Standard), personalized angles (Blinded), and personalized angles while concurrently referring to 3D CT (Referred). Results Control measurements correlated and agreed better with Referred and Blinded measurements than with Standard measurements (diameter correlation and agreement: Control/Standard r=.554, limits of agreement [LOAs]=6.83/-5.91; Control/Blinded r=.641, LOA =5.67/-5.54; Control/Referred r=.741, LOA=4.69/-4.14; length correlation and agreement: Control/Standard r(s)=.829, LOA=9.61/-3.02; Control/Blinded r(s)=0.789, LOA=7.13/-4.94; Control/Referred r(s)=.907, LOA=4.84/-4.13). Personalized angles resulted in hypothetical device size predictions more consistent with Control (device size correlation: Control/Standard r(s)=.698, Control/Blinded r(s)=.731, Control/Referred r(s)=.893, P<0.001). False ineligibility rates were Standard=6/28, Blinded=6/28, and Referred=2/28. Conclusion This simulation suggests that personalized fluoroscopic viewing angles with in-procedural reference to 3D CT may improve the accuracy of LAA maximum landing zone diameter and length measurements at the Watchman landing zone. This improvement may result in more consistent device size selection and procedural eligibility assessment. Further clinical research on these interventions is merited. Cureus 2020-06-23 /pmc/articles/PMC7381882/ /pubmed/32724734 http://dx.doi.org/10.7759/cureus.8783 Text en Copyright © 2020, Shee et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Cardiology
Shee, Vikram
He, Liwei
Liu, Shenrong
Huang, Xingfu
Chen, Yanyu
Xie, Liangzhen
Deng, Xiaojiang
Peng, Jian
Personalized Fluoroscopic Angles in Watchman™ Left Atrial Appendage Closure Landing Zone Assessment: A Three-Dimensional Printed Simulation Study
title Personalized Fluoroscopic Angles in Watchman™ Left Atrial Appendage Closure Landing Zone Assessment: A Three-Dimensional Printed Simulation Study
title_full Personalized Fluoroscopic Angles in Watchman™ Left Atrial Appendage Closure Landing Zone Assessment: A Three-Dimensional Printed Simulation Study
title_fullStr Personalized Fluoroscopic Angles in Watchman™ Left Atrial Appendage Closure Landing Zone Assessment: A Three-Dimensional Printed Simulation Study
title_full_unstemmed Personalized Fluoroscopic Angles in Watchman™ Left Atrial Appendage Closure Landing Zone Assessment: A Three-Dimensional Printed Simulation Study
title_short Personalized Fluoroscopic Angles in Watchman™ Left Atrial Appendage Closure Landing Zone Assessment: A Three-Dimensional Printed Simulation Study
title_sort personalized fluoroscopic angles in watchman™ left atrial appendage closure landing zone assessment: a three-dimensional printed simulation study
topic Cardiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7381882/
https://www.ncbi.nlm.nih.gov/pubmed/32724734
http://dx.doi.org/10.7759/cureus.8783
work_keys_str_mv AT sheevikram personalizedfluoroscopicanglesinwatchmanleftatrialappendageclosurelandingzoneassessmentathreedimensionalprintedsimulationstudy
AT heliwei personalizedfluoroscopicanglesinwatchmanleftatrialappendageclosurelandingzoneassessmentathreedimensionalprintedsimulationstudy
AT liushenrong personalizedfluoroscopicanglesinwatchmanleftatrialappendageclosurelandingzoneassessmentathreedimensionalprintedsimulationstudy
AT huangxingfu personalizedfluoroscopicanglesinwatchmanleftatrialappendageclosurelandingzoneassessmentathreedimensionalprintedsimulationstudy
AT chenyanyu personalizedfluoroscopicanglesinwatchmanleftatrialappendageclosurelandingzoneassessmentathreedimensionalprintedsimulationstudy
AT xieliangzhen personalizedfluoroscopicanglesinwatchmanleftatrialappendageclosurelandingzoneassessmentathreedimensionalprintedsimulationstudy
AT dengxiaojiang personalizedfluoroscopicanglesinwatchmanleftatrialappendageclosurelandingzoneassessmentathreedimensionalprintedsimulationstudy
AT pengjian personalizedfluoroscopicanglesinwatchmanleftatrialappendageclosurelandingzoneassessmentathreedimensionalprintedsimulationstudy