Cargando…

How frequency hopping suppresses pulse-echo ambiguity in bat biosonar

Big brown bats transmit wideband FM biosonar sounds that sweep from 55 to 25 kHz (first harmonic, FM1) and from 110 to 50 kHz (second harmonic, FM2). FM1 is required to perceive echo delay for target ranging; FM2 contributes only if corresponding FM1 frequencies are present. We show that echoes need...

Descripción completa

Detalles Bibliográficos
Autores principales: Ming, Chen, Bates, Mary E., Simmons, James A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: National Academy of Sciences 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7382275/
https://www.ncbi.nlm.nih.gov/pubmed/32632013
http://dx.doi.org/10.1073/pnas.2001105117
_version_ 1783563214517174272
author Ming, Chen
Bates, Mary E.
Simmons, James A.
author_facet Ming, Chen
Bates, Mary E.
Simmons, James A.
author_sort Ming, Chen
collection PubMed
description Big brown bats transmit wideband FM biosonar sounds that sweep from 55 to 25 kHz (first harmonic, FM1) and from 110 to 50 kHz (second harmonic, FM2). FM1 is required to perceive echo delay for target ranging; FM2 contributes only if corresponding FM1 frequencies are present. We show that echoes need only the lowest FM1 broadcast frequencies of 25 to 30 kHz for delay perception. If these frequencies are removed, no delay is perceived. Bats begin echo processing at the lowest frequencies and accumulate perceptual acuity over successively higher frequencies, but they cannot proceed without the low-frequency starting point in their broadcasts. This reveals a solution to pulse-echo ambiguity, a serious problem for radar or sonar. In dense, extended biosonar scenes, bats have to emit sounds rapidly to avoid collisions with near objects. But if a new broadcast is emitted when echoes of the previous broadcast still are arriving, echoes from both broadcasts intermingle, creating ambiguity about which echo corresponds to which broadcast. Frequency hopping by several kilohertz from one broadcast to the next can segregate overlapping narrowband echo streams, but wideband FM echoes ordinarily do not segregate because their spectra still overlap. By starting echo processing at the lowest frequencies in frequency-hopped broadcasts, echoes of the higher hopped broadcast are prevented from being accepted by lower hopped broadcasts, and ambiguity is avoided. The bat-inspired spectrogram correlation and transformation (SCAT) model also begins at the lowest frequencies; echoes that lack them are eliminated from processing of delay and no longer cause ambiguity.
format Online
Article
Text
id pubmed-7382275
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher National Academy of Sciences
record_format MEDLINE/PubMed
spelling pubmed-73822752020-07-30 How frequency hopping suppresses pulse-echo ambiguity in bat biosonar Ming, Chen Bates, Mary E. Simmons, James A. Proc Natl Acad Sci U S A Biological Sciences Big brown bats transmit wideband FM biosonar sounds that sweep from 55 to 25 kHz (first harmonic, FM1) and from 110 to 50 kHz (second harmonic, FM2). FM1 is required to perceive echo delay for target ranging; FM2 contributes only if corresponding FM1 frequencies are present. We show that echoes need only the lowest FM1 broadcast frequencies of 25 to 30 kHz for delay perception. If these frequencies are removed, no delay is perceived. Bats begin echo processing at the lowest frequencies and accumulate perceptual acuity over successively higher frequencies, but they cannot proceed without the low-frequency starting point in their broadcasts. This reveals a solution to pulse-echo ambiguity, a serious problem for radar or sonar. In dense, extended biosonar scenes, bats have to emit sounds rapidly to avoid collisions with near objects. But if a new broadcast is emitted when echoes of the previous broadcast still are arriving, echoes from both broadcasts intermingle, creating ambiguity about which echo corresponds to which broadcast. Frequency hopping by several kilohertz from one broadcast to the next can segregate overlapping narrowband echo streams, but wideband FM echoes ordinarily do not segregate because their spectra still overlap. By starting echo processing at the lowest frequencies in frequency-hopped broadcasts, echoes of the higher hopped broadcast are prevented from being accepted by lower hopped broadcasts, and ambiguity is avoided. The bat-inspired spectrogram correlation and transformation (SCAT) model also begins at the lowest frequencies; echoes that lack them are eliminated from processing of delay and no longer cause ambiguity. National Academy of Sciences 2020-07-21 2020-07-06 /pmc/articles/PMC7382275/ /pubmed/32632013 http://dx.doi.org/10.1073/pnas.2001105117 Text en Copyright © 2020 the Author(s). Published by PNAS. https://creativecommons.org/licenses/by-nc-nd/4.0/ https://creativecommons.org/licenses/by-nc-nd/4.0/This open access article is distributed under Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0 (CC BY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Biological Sciences
Ming, Chen
Bates, Mary E.
Simmons, James A.
How frequency hopping suppresses pulse-echo ambiguity in bat biosonar
title How frequency hopping suppresses pulse-echo ambiguity in bat biosonar
title_full How frequency hopping suppresses pulse-echo ambiguity in bat biosonar
title_fullStr How frequency hopping suppresses pulse-echo ambiguity in bat biosonar
title_full_unstemmed How frequency hopping suppresses pulse-echo ambiguity in bat biosonar
title_short How frequency hopping suppresses pulse-echo ambiguity in bat biosonar
title_sort how frequency hopping suppresses pulse-echo ambiguity in bat biosonar
topic Biological Sciences
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7382275/
https://www.ncbi.nlm.nih.gov/pubmed/32632013
http://dx.doi.org/10.1073/pnas.2001105117
work_keys_str_mv AT mingchen howfrequencyhoppingsuppressespulseechoambiguityinbatbiosonar
AT batesmarye howfrequencyhoppingsuppressespulseechoambiguityinbatbiosonar
AT simmonsjamesa howfrequencyhoppingsuppressespulseechoambiguityinbatbiosonar