Pneumonia: Hiding in Plain (Film) Sight

Herein, a case describing how point-of-care lung ultrasound was used to identify the source of progressive multiorgan failure when a chest x-ray and other routine tests failed to provide a conclusive answer is presented. The discussion after the case focuses on the following: (1) the relative streng...

Descripción completa

Detalles Bibliográficos
Autores principales: Fox, William C., Krishnamoorthy, Vijay, Hashmi, Nazish, Bronshteyn, Yuriy S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: W.B. Saunders 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7382342/
https://www.ncbi.nlm.nih.gov/pubmed/32798171
http://dx.doi.org/10.1053/j.jvca.2020.07.062
Descripción
Sumario:Herein, a case describing how point-of-care lung ultrasound was used to identify the source of progressive multiorgan failure when a chest x-ray and other routine tests failed to provide a conclusive answer is presented. The discussion after the case focuses on the following: (1) the relative strengths and weaknesses of chest x-ray versus lung ultrasound in screening for lung disease and (2) suggestions of how lung ultrasound practice can be standardized within the field of anesthesiology.