Development of an Infrared Monitor-Guided Bleb Revision Procedure
The needle revision procedure to address failing filtering blebs is a blind technique that might easily damage the scleral flap, conjunctiva, and choroid. We propose a new surgical procedure, infrared monitor-guided bleb revision, to perform bleb revision minimally invasively and effectively, and de...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
S. Karger AG
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7383186/ https://www.ncbi.nlm.nih.gov/pubmed/32774286 http://dx.doi.org/10.1159/000508606 |
_version_ | 1783563397095227392 |
---|---|
author | Matsushita, Kenji Kawashima, Rumi Nishida, Kohji |
author_facet | Matsushita, Kenji Kawashima, Rumi Nishida, Kohji |
author_sort | Matsushita, Kenji |
collection | PubMed |
description | The needle revision procedure to address failing filtering blebs is a blind technique that might easily damage the scleral flap, conjunctiva, and choroid. We propose a new surgical procedure, infrared monitor-guided bleb revision, to perform bleb revision minimally invasively and effectively, and demonstrate the procedure in a patient. We developed the guided procedure with the infrared monitor to observe the bleb interior with greater contrast. Under the monitor, we dissect the hard fibrotic tissue with a bleb knife and, if necessary, remove adhesions using a needle and vitreous forceps. Finally, 5-fluorouracil is injected into the subconjunctiva. We have performed bleb revisions safely with clear visualization of the scleral flap using an infrared light. In the current case, the patient had good intraocular pressure control for about 1 year. The new infrared monitor-guided bleb revision procedure facilitates successful bleb revisions without damage to the underlying structures. |
format | Online Article Text |
id | pubmed-7383186 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | S. Karger AG |
record_format | MEDLINE/PubMed |
spelling | pubmed-73831862020-08-07 Development of an Infrared Monitor-Guided Bleb Revision Procedure Matsushita, Kenji Kawashima, Rumi Nishida, Kohji Case Rep Ophthalmol Case Report The needle revision procedure to address failing filtering blebs is a blind technique that might easily damage the scleral flap, conjunctiva, and choroid. We propose a new surgical procedure, infrared monitor-guided bleb revision, to perform bleb revision minimally invasively and effectively, and demonstrate the procedure in a patient. We developed the guided procedure with the infrared monitor to observe the bleb interior with greater contrast. Under the monitor, we dissect the hard fibrotic tissue with a bleb knife and, if necessary, remove adhesions using a needle and vitreous forceps. Finally, 5-fluorouracil is injected into the subconjunctiva. We have performed bleb revisions safely with clear visualization of the scleral flap using an infrared light. In the current case, the patient had good intraocular pressure control for about 1 year. The new infrared monitor-guided bleb revision procedure facilitates successful bleb revisions without damage to the underlying structures. S. Karger AG 2020-06-25 /pmc/articles/PMC7383186/ /pubmed/32774286 http://dx.doi.org/10.1159/000508606 Text en Copyright © 2020 by S. Karger AG, Basel http://creativecommons.org/licenses/by-nc/4.0/ This article is licensed under the Creative Commons Attribution-NonCommercial-4.0 International License (CC BY-NC) (http://www.karger.com/Services/OpenAccessLicense). Usage and distribution for commercial purposes requires written permission. |
spellingShingle | Case Report Matsushita, Kenji Kawashima, Rumi Nishida, Kohji Development of an Infrared Monitor-Guided Bleb Revision Procedure |
title | Development of an Infrared Monitor-Guided Bleb Revision Procedure |
title_full | Development of an Infrared Monitor-Guided Bleb Revision Procedure |
title_fullStr | Development of an Infrared Monitor-Guided Bleb Revision Procedure |
title_full_unstemmed | Development of an Infrared Monitor-Guided Bleb Revision Procedure |
title_short | Development of an Infrared Monitor-Guided Bleb Revision Procedure |
title_sort | development of an infrared monitor-guided bleb revision procedure |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7383186/ https://www.ncbi.nlm.nih.gov/pubmed/32774286 http://dx.doi.org/10.1159/000508606 |
work_keys_str_mv | AT matsushitakenji developmentofaninfraredmonitorguidedblebrevisionprocedure AT kawashimarumi developmentofaninfraredmonitorguidedblebrevisionprocedure AT nishidakohji developmentofaninfraredmonitorguidedblebrevisionprocedure |