Cargando…

Development of an Infrared Monitor-Guided Bleb Revision Procedure

The needle revision procedure to address failing filtering blebs is a blind technique that might easily damage the scleral flap, conjunctiva, and choroid. We propose a new surgical procedure, infrared monitor-guided bleb revision, to perform bleb revision minimally invasively and effectively, and de...

Descripción completa

Detalles Bibliográficos
Autores principales: Matsushita, Kenji, Kawashima, Rumi, Nishida, Kohji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: S. Karger AG 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7383186/
https://www.ncbi.nlm.nih.gov/pubmed/32774286
http://dx.doi.org/10.1159/000508606
_version_ 1783563397095227392
author Matsushita, Kenji
Kawashima, Rumi
Nishida, Kohji
author_facet Matsushita, Kenji
Kawashima, Rumi
Nishida, Kohji
author_sort Matsushita, Kenji
collection PubMed
description The needle revision procedure to address failing filtering blebs is a blind technique that might easily damage the scleral flap, conjunctiva, and choroid. We propose a new surgical procedure, infrared monitor-guided bleb revision, to perform bleb revision minimally invasively and effectively, and demonstrate the procedure in a patient. We developed the guided procedure with the infrared monitor to observe the bleb interior with greater contrast. Under the monitor, we dissect the hard fibrotic tissue with a bleb knife and, if necessary, remove adhesions using a needle and vitreous forceps. Finally, 5-fluorouracil is injected into the subconjunctiva. We have performed bleb revisions safely with clear visualization of the scleral flap using an infrared light. In the current case, the patient had good intraocular pressure control for about 1 year. The new infrared monitor-guided bleb revision procedure facilitates successful bleb revisions without damage to the underlying structures.
format Online
Article
Text
id pubmed-7383186
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher S. Karger AG
record_format MEDLINE/PubMed
spelling pubmed-73831862020-08-07 Development of an Infrared Monitor-Guided Bleb Revision Procedure Matsushita, Kenji Kawashima, Rumi Nishida, Kohji Case Rep Ophthalmol Case Report The needle revision procedure to address failing filtering blebs is a blind technique that might easily damage the scleral flap, conjunctiva, and choroid. We propose a new surgical procedure, infrared monitor-guided bleb revision, to perform bleb revision minimally invasively and effectively, and demonstrate the procedure in a patient. We developed the guided procedure with the infrared monitor to observe the bleb interior with greater contrast. Under the monitor, we dissect the hard fibrotic tissue with a bleb knife and, if necessary, remove adhesions using a needle and vitreous forceps. Finally, 5-fluorouracil is injected into the subconjunctiva. We have performed bleb revisions safely with clear visualization of the scleral flap using an infrared light. In the current case, the patient had good intraocular pressure control for about 1 year. The new infrared monitor-guided bleb revision procedure facilitates successful bleb revisions without damage to the underlying structures. S. Karger AG 2020-06-25 /pmc/articles/PMC7383186/ /pubmed/32774286 http://dx.doi.org/10.1159/000508606 Text en Copyright © 2020 by S. Karger AG, Basel http://creativecommons.org/licenses/by-nc/4.0/ This article is licensed under the Creative Commons Attribution-NonCommercial-4.0 International License (CC BY-NC) (http://www.karger.com/Services/OpenAccessLicense). Usage and distribution for commercial purposes requires written permission.
spellingShingle Case Report
Matsushita, Kenji
Kawashima, Rumi
Nishida, Kohji
Development of an Infrared Monitor-Guided Bleb Revision Procedure
title Development of an Infrared Monitor-Guided Bleb Revision Procedure
title_full Development of an Infrared Monitor-Guided Bleb Revision Procedure
title_fullStr Development of an Infrared Monitor-Guided Bleb Revision Procedure
title_full_unstemmed Development of an Infrared Monitor-Guided Bleb Revision Procedure
title_short Development of an Infrared Monitor-Guided Bleb Revision Procedure
title_sort development of an infrared monitor-guided bleb revision procedure
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7383186/
https://www.ncbi.nlm.nih.gov/pubmed/32774286
http://dx.doi.org/10.1159/000508606
work_keys_str_mv AT matsushitakenji developmentofaninfraredmonitorguidedblebrevisionprocedure
AT kawashimarumi developmentofaninfraredmonitorguidedblebrevisionprocedure
AT nishidakohji developmentofaninfraredmonitorguidedblebrevisionprocedure