Cargando…
Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study)
BACKGROUND: The purpose of this in-vitro study was to evaluate the effect of dynamic cyclic loading on screw loosening of retightened abutment screw versus new abutment screw in both narrow and standard implants. METHODS: Separate acrylic resin blocks containing implant assembly (fixture, abutment,...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7385049/ https://www.ncbi.nlm.nih.gov/pubmed/32720011 http://dx.doi.org/10.1186/s40729-020-00229-3 |
_version_ | 1783563699140689920 |
---|---|
author | Attiah, Eman Mohammed Nasr AlGendy, Attiah Ali Mostafa, Tamer Mohamed Nasr |
author_facet | Attiah, Eman Mohammed Nasr AlGendy, Attiah Ali Mostafa, Tamer Mohamed Nasr |
author_sort | Attiah, Eman Mohammed Nasr |
collection | PubMed |
description | BACKGROUND: The purpose of this in-vitro study was to evaluate the effect of dynamic cyclic loading on screw loosening of retightened abutment screw versus new abutment screw in both narrow and standard implants. METHODS: Separate acrylic resin blocks containing implant assembly (fixture, abutment, abutment screw, metal tube capping the abutment). Samples were divided into two main groups according to the diameter of implant: group 1 (GI 4.5-mm diameter) and group 2 (GII 3-mm diameter). Each group is subdivided into two subgroups according to the suggested option to manage screw loosening either by retightening (GIA, GIIA) or using new screws (GIB, GIIB). One hundred thousand cycles of eccentric dynamic cyclic loading (DCL) were applied before and after retightening or replacing the screw; then, removal torque loss (RTL) ratio was calculated, tabulated, and analyzed by t-student, ANOVA, pair wise Tukey’s tests. RESULTS: There were differences between GI and GII regarding the incidence of screw loosening process. Removal torque loss ratio was higher in GIB and GIIB where the old abutment screws were replaced by new screws for both standard implants (SIs) and narrow diameter implants (NDIs). There was significant effect of retightening and replacing the abutment screws after exposure to DCL. CONCLUSIONS: Within the limitations of this in-vitro study, it can be conclude that screw loosening process occurred in both SIs and NDIs but with higher values in NDIs. It is better to retighten the screw of NDIs and SIs than replacing it with a new screw. |
format | Online Article Text |
id | pubmed-7385049 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-73850492020-08-04 Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study) Attiah, Eman Mohammed Nasr AlGendy, Attiah Ali Mostafa, Tamer Mohamed Nasr Int J Implant Dent Research BACKGROUND: The purpose of this in-vitro study was to evaluate the effect of dynamic cyclic loading on screw loosening of retightened abutment screw versus new abutment screw in both narrow and standard implants. METHODS: Separate acrylic resin blocks containing implant assembly (fixture, abutment, abutment screw, metal tube capping the abutment). Samples were divided into two main groups according to the diameter of implant: group 1 (GI 4.5-mm diameter) and group 2 (GII 3-mm diameter). Each group is subdivided into two subgroups according to the suggested option to manage screw loosening either by retightening (GIA, GIIA) or using new screws (GIB, GIIB). One hundred thousand cycles of eccentric dynamic cyclic loading (DCL) were applied before and after retightening or replacing the screw; then, removal torque loss (RTL) ratio was calculated, tabulated, and analyzed by t-student, ANOVA, pair wise Tukey’s tests. RESULTS: There were differences between GI and GII regarding the incidence of screw loosening process. Removal torque loss ratio was higher in GIB and GIIB where the old abutment screws were replaced by new screws for both standard implants (SIs) and narrow diameter implants (NDIs). There was significant effect of retightening and replacing the abutment screws after exposure to DCL. CONCLUSIONS: Within the limitations of this in-vitro study, it can be conclude that screw loosening process occurred in both SIs and NDIs but with higher values in NDIs. It is better to retighten the screw of NDIs and SIs than replacing it with a new screw. Springer Berlin Heidelberg 2020-07-28 /pmc/articles/PMC7385049/ /pubmed/32720011 http://dx.doi.org/10.1186/s40729-020-00229-3 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Research Attiah, Eman Mohammed Nasr AlGendy, Attiah Ali Mostafa, Tamer Mohamed Nasr Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study) |
title | Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study) |
title_full | Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study) |
title_fullStr | Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study) |
title_full_unstemmed | Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study) |
title_short | Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study) |
title_sort | effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study) |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7385049/ https://www.ncbi.nlm.nih.gov/pubmed/32720011 http://dx.doi.org/10.1186/s40729-020-00229-3 |
work_keys_str_mv | AT attiahemanmohammednasr effectofdynamiccyclicloadingonscrewlooseningofretightenedversusnewabutmentscrewinbothnarrowandstandardimplantsinvitrostudy AT algendyattiahali effectofdynamiccyclicloadingonscrewlooseningofretightenedversusnewabutmentscrewinbothnarrowandstandardimplantsinvitrostudy AT mostafatamermohamednasr effectofdynamiccyclicloadingonscrewlooseningofretightenedversusnewabutmentscrewinbothnarrowandstandardimplantsinvitrostudy |