Cargando…
Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application
There is a lack of commercially available low-cost technologies to assess gait clinically in non-controlled environments. As a consequence of this, there has been poor massification of motion measurement technologies that are both objective and reliable in nature. Advances about the study of gait an...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
PAGEPress Publications, Pavia, Italy
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7385685/ https://www.ncbi.nlm.nih.gov/pubmed/32782764 http://dx.doi.org/10.4081/ejtm.2019.9002 |
_version_ | 1783563834865221632 |
---|---|
author | Aqueveque, Pablo Gómez, Britam Saavedra, Francisco Canales, Cristian Contreras, Simón Ortega-Bastidas, Paulina Cano-de-la-Cuerda, Roberto |
author_facet | Aqueveque, Pablo Gómez, Britam Saavedra, Francisco Canales, Cristian Contreras, Simón Ortega-Bastidas, Paulina Cano-de-la-Cuerda, Roberto |
author_sort | Aqueveque, Pablo |
collection | PubMed |
description | There is a lack of commercially available low-cost technologies to assess gait clinically in non-controlled environments. As a consequence of this, there has been poor massification of motion measurement technologies that are both objective and reliable in nature. Advances about the study of gait and its interpretation in recent years using inertial sensors have allowed proposing acceptable alternatives for the development of portable and low-cost systems that contribute to people’s health in places and institutions that cannot acquire or maintain the operation of commercially available systems. A system based on a custom single Inertial Measurement Unit and a mobile application is proposed. Thus, an investigation is carried out using methodologies and algorithms found in the literature in order to get the main gait events and the spatial-temporal gait parameters. Twenty healthy Chilean subjects were assessed using a motion capture system simultaneously with the proposed tool. The results show that it is possible to estimate temporal gait parameters with slight differences respect gold--standard. We reach maximum mean differences of -2.35±5.02[step/min] for cadence, 0.03±0.04[sec] for stride time,0.02±0.03[sec] for step time, ±0.02[sec] for a single support time, 0.01±0.02[sec] for double support time and 0.01±0.03[m] for step length. As a result of experimental findings, we propose a new technological tool that can perform gait analysis. Our proposed system is user-friendly, low-cost, and portable. Therefore, we suggest that it could be an attractive technological tool that healthcare professionals could harness to objectively measure gait in environments that are either within the community or controlled. We also suggest that the tool could be used in countries where advanced clinical tools cannot be acquired. Therefore, we propose in this paper that our system is an attractive, alternative system that can be used for gait analysis by health professionals worldwide. |
format | Online Article Text |
id | pubmed-7385685 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | PAGEPress Publications, Pavia, Italy |
record_format | MEDLINE/PubMed |
spelling | pubmed-73856852020-08-10 Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application Aqueveque, Pablo Gómez, Britam Saavedra, Francisco Canales, Cristian Contreras, Simón Ortega-Bastidas, Paulina Cano-de-la-Cuerda, Roberto Eur J Transl Myol Article There is a lack of commercially available low-cost technologies to assess gait clinically in non-controlled environments. As a consequence of this, there has been poor massification of motion measurement technologies that are both objective and reliable in nature. Advances about the study of gait and its interpretation in recent years using inertial sensors have allowed proposing acceptable alternatives for the development of portable and low-cost systems that contribute to people’s health in places and institutions that cannot acquire or maintain the operation of commercially available systems. A system based on a custom single Inertial Measurement Unit and a mobile application is proposed. Thus, an investigation is carried out using methodologies and algorithms found in the literature in order to get the main gait events and the spatial-temporal gait parameters. Twenty healthy Chilean subjects were assessed using a motion capture system simultaneously with the proposed tool. The results show that it is possible to estimate temporal gait parameters with slight differences respect gold--standard. We reach maximum mean differences of -2.35±5.02[step/min] for cadence, 0.03±0.04[sec] for stride time,0.02±0.03[sec] for step time, ±0.02[sec] for a single support time, 0.01±0.02[sec] for double support time and 0.01±0.03[m] for step length. As a result of experimental findings, we propose a new technological tool that can perform gait analysis. Our proposed system is user-friendly, low-cost, and portable. Therefore, we suggest that it could be an attractive technological tool that healthcare professionals could harness to objectively measure gait in environments that are either within the community or controlled. We also suggest that the tool could be used in countries where advanced clinical tools cannot be acquired. Therefore, we propose in this paper that our system is an attractive, alternative system that can be used for gait analysis by health professionals worldwide. PAGEPress Publications, Pavia, Italy 2020-06-22 /pmc/articles/PMC7385685/ /pubmed/32782764 http://dx.doi.org/10.4081/ejtm.2019.9002 Text en http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License (by-nc 4.0) which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Article Aqueveque, Pablo Gómez, Britam Saavedra, Francisco Canales, Cristian Contreras, Simón Ortega-Bastidas, Paulina Cano-de-la-Cuerda, Roberto Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application |
title | Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application |
title_full | Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application |
title_fullStr | Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application |
title_full_unstemmed | Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application |
title_short | Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application |
title_sort | validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7385685/ https://www.ncbi.nlm.nih.gov/pubmed/32782764 http://dx.doi.org/10.4081/ejtm.2019.9002 |
work_keys_str_mv | AT aquevequepablo validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication AT gomezbritam validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication AT saavedrafrancisco validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication AT canalescristian validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication AT contrerassimon validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication AT ortegabastidaspaulina validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication AT canodelacuerdaroberto validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication |