Cargando…

Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application

There is a lack of commercially available low-cost technologies to assess gait clinically in non-controlled environments. As a consequence of this, there has been poor massification of motion measurement technologies that are both objective and reliable in nature. Advances about the study of gait an...

Descripción completa

Detalles Bibliográficos
Autores principales: Aqueveque, Pablo, Gómez, Britam, Saavedra, Francisco, Canales, Cristian, Contreras, Simón, Ortega-Bastidas, Paulina, Cano-de-la-Cuerda, Roberto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PAGEPress Publications, Pavia, Italy 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7385685/
https://www.ncbi.nlm.nih.gov/pubmed/32782764
http://dx.doi.org/10.4081/ejtm.2019.9002
_version_ 1783563834865221632
author Aqueveque, Pablo
Gómez, Britam
Saavedra, Francisco
Canales, Cristian
Contreras, Simón
Ortega-Bastidas, Paulina
Cano-de-la-Cuerda, Roberto
author_facet Aqueveque, Pablo
Gómez, Britam
Saavedra, Francisco
Canales, Cristian
Contreras, Simón
Ortega-Bastidas, Paulina
Cano-de-la-Cuerda, Roberto
author_sort Aqueveque, Pablo
collection PubMed
description There is a lack of commercially available low-cost technologies to assess gait clinically in non-controlled environments. As a consequence of this, there has been poor massification of motion measurement technologies that are both objective and reliable in nature. Advances about the study of gait and its interpretation in recent years using inertial sensors have allowed proposing acceptable alternatives for the development of portable and low-cost systems that contribute to people’s health in places and institutions that cannot acquire or maintain the operation of commercially available systems. A system based on a custom single Inertial Measurement Unit and a mobile application is proposed. Thus, an investigation is carried out using methodologies and algorithms found in the literature in order to get the main gait events and the spatial-temporal gait parameters. Twenty healthy Chilean subjects were assessed using a motion capture system simultaneously with the proposed tool. The results show that it is possible to estimate temporal gait parameters with slight differences respect gold--standard. We reach maximum mean differences of -2.35±5.02[step/min] for cadence, 0.03±0.04[sec] for stride time,0.02±0.03[sec] for step time, ±0.02[sec] for a single support time, 0.01±0.02[sec] for double support time and 0.01±0.03[m] for step length. As a result of experimental findings, we propose a new technological tool that can perform gait analysis. Our proposed system is user-friendly, low-cost, and portable. Therefore, we suggest that it could be an attractive technological tool that healthcare professionals could harness to objectively measure gait in environments that are either within the community or controlled. We also suggest that the tool could be used in countries where advanced clinical tools cannot be acquired. Therefore, we propose in this paper that our system is an attractive, alternative system that can be used for gait analysis by health professionals worldwide.
format Online
Article
Text
id pubmed-7385685
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher PAGEPress Publications, Pavia, Italy
record_format MEDLINE/PubMed
spelling pubmed-73856852020-08-10 Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application Aqueveque, Pablo Gómez, Britam Saavedra, Francisco Canales, Cristian Contreras, Simón Ortega-Bastidas, Paulina Cano-de-la-Cuerda, Roberto Eur J Transl Myol Article There is a lack of commercially available low-cost technologies to assess gait clinically in non-controlled environments. As a consequence of this, there has been poor massification of motion measurement technologies that are both objective and reliable in nature. Advances about the study of gait and its interpretation in recent years using inertial sensors have allowed proposing acceptable alternatives for the development of portable and low-cost systems that contribute to people’s health in places and institutions that cannot acquire or maintain the operation of commercially available systems. A system based on a custom single Inertial Measurement Unit and a mobile application is proposed. Thus, an investigation is carried out using methodologies and algorithms found in the literature in order to get the main gait events and the spatial-temporal gait parameters. Twenty healthy Chilean subjects were assessed using a motion capture system simultaneously with the proposed tool. The results show that it is possible to estimate temporal gait parameters with slight differences respect gold--standard. We reach maximum mean differences of -2.35±5.02[step/min] for cadence, 0.03±0.04[sec] for stride time,0.02±0.03[sec] for step time, ±0.02[sec] for a single support time, 0.01±0.02[sec] for double support time and 0.01±0.03[m] for step length. As a result of experimental findings, we propose a new technological tool that can perform gait analysis. Our proposed system is user-friendly, low-cost, and portable. Therefore, we suggest that it could be an attractive technological tool that healthcare professionals could harness to objectively measure gait in environments that are either within the community or controlled. We also suggest that the tool could be used in countries where advanced clinical tools cannot be acquired. Therefore, we propose in this paper that our system is an attractive, alternative system that can be used for gait analysis by health professionals worldwide. PAGEPress Publications, Pavia, Italy 2020-06-22 /pmc/articles/PMC7385685/ /pubmed/32782764 http://dx.doi.org/10.4081/ejtm.2019.9002 Text en http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License (by-nc 4.0) which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Article
Aqueveque, Pablo
Gómez, Britam
Saavedra, Francisco
Canales, Cristian
Contreras, Simón
Ortega-Bastidas, Paulina
Cano-de-la-Cuerda, Roberto
Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application
title Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application
title_full Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application
title_fullStr Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application
title_full_unstemmed Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application
title_short Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application
title_sort validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7385685/
https://www.ncbi.nlm.nih.gov/pubmed/32782764
http://dx.doi.org/10.4081/ejtm.2019.9002
work_keys_str_mv AT aquevequepablo validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication
AT gomezbritam validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication
AT saavedrafrancisco validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication
AT canalescristian validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication
AT contrerassimon validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication
AT ortegabastidaspaulina validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication
AT canodelacuerdaroberto validationofaportablesystemforspatialtemporalgaitparametersbasedonasingleinertialmeasurementunitandamobileapplication