A novel dynamic robotic moving phantom system for patient‐specific quality assurance in real‐time tumor‐tracking radiotherapy
In this study, we assess a developed novel dynamic moving phantom system that can reproduce patient three‐dimensional (3D) tumor motion and patient anatomy, and perform patient‐specific quality assurance (QA) of respiratory‐gated radiotherapy using SyncTraX. Three patients with lung cancer were enro...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7386190/ https://www.ncbi.nlm.nih.gov/pubmed/32281265 http://dx.doi.org/10.1002/acm2.12876 |
_version_ | 1783563907613327360 |
---|---|
author | Shiinoki, Takehiro Fujii, Fumitake Fujimoto, Koya Yuasa, Yuki Sera, Tatsuhiro |
author_facet | Shiinoki, Takehiro Fujii, Fumitake Fujimoto, Koya Yuasa, Yuki Sera, Tatsuhiro |
author_sort | Shiinoki, Takehiro |
collection | PubMed |
description | In this study, we assess a developed novel dynamic moving phantom system that can reproduce patient three‐dimensional (3D) tumor motion and patient anatomy, and perform patient‐specific quality assurance (QA) of respiratory‐gated radiotherapy using SyncTraX. Three patients with lung cancer were enrolled in a study. 3D printing technology was adopted to obtain individualized lung phantoms using CT images. A water‐equivalent phantom (WEP) with the 3D‐printed plate lung phantom was set at the tip of the robotic arm. The log file that recorded the 3D positions of the lung tumor was used as the input to the dynamic robotic moving phantom. The WEP was driven to track 3D respiratory motion. Respiratory‐gated radiotherapy was performed for driving the WEP. The tracking accuracy was calculated as the differences between the actual and measured positions. For the absolute dose and dose distribution, the differences between the planned and measured doses were calculated. The differences between the planned and measured absolute doses were <1.0% at the isocenter and <4.0% for the lung region. The gamma pass ratios of γ(3 mm/3%) and γ(2 mm/2%) under the conditions of gating and no‐gating were 99.9 ± 0.1% and 90.1 ± 8.5%, and 97.5 ± 0.9% and 68.6 ± 17.8%, respectively, for all the patients. Furthermore, for all the patients, the mean ± SD of the root mean square values of the positional error were 0.11 ± 0.04 mm, 0.33 ± 0.04 mm, and 0.20 ± 0.04 mm in the LR, AP, and SI directions, respectively. Finally, we showed that patient‐specific QA of respiratory‐gated radiotherapy using SyncTraX can be performed under realistic conditions using the moving phantom. |
format | Online Article Text |
id | pubmed-7386190 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-73861902020-07-30 A novel dynamic robotic moving phantom system for patient‐specific quality assurance in real‐time tumor‐tracking radiotherapy Shiinoki, Takehiro Fujii, Fumitake Fujimoto, Koya Yuasa, Yuki Sera, Tatsuhiro J Appl Clin Med Phys Radiation Oncology Physics In this study, we assess a developed novel dynamic moving phantom system that can reproduce patient three‐dimensional (3D) tumor motion and patient anatomy, and perform patient‐specific quality assurance (QA) of respiratory‐gated radiotherapy using SyncTraX. Three patients with lung cancer were enrolled in a study. 3D printing technology was adopted to obtain individualized lung phantoms using CT images. A water‐equivalent phantom (WEP) with the 3D‐printed plate lung phantom was set at the tip of the robotic arm. The log file that recorded the 3D positions of the lung tumor was used as the input to the dynamic robotic moving phantom. The WEP was driven to track 3D respiratory motion. Respiratory‐gated radiotherapy was performed for driving the WEP. The tracking accuracy was calculated as the differences between the actual and measured positions. For the absolute dose and dose distribution, the differences between the planned and measured doses were calculated. The differences between the planned and measured absolute doses were <1.0% at the isocenter and <4.0% for the lung region. The gamma pass ratios of γ(3 mm/3%) and γ(2 mm/2%) under the conditions of gating and no‐gating were 99.9 ± 0.1% and 90.1 ± 8.5%, and 97.5 ± 0.9% and 68.6 ± 17.8%, respectively, for all the patients. Furthermore, for all the patients, the mean ± SD of the root mean square values of the positional error were 0.11 ± 0.04 mm, 0.33 ± 0.04 mm, and 0.20 ± 0.04 mm in the LR, AP, and SI directions, respectively. Finally, we showed that patient‐specific QA of respiratory‐gated radiotherapy using SyncTraX can be performed under realistic conditions using the moving phantom. John Wiley and Sons Inc. 2020-04-13 /pmc/articles/PMC7386190/ /pubmed/32281265 http://dx.doi.org/10.1002/acm2.12876 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Shiinoki, Takehiro Fujii, Fumitake Fujimoto, Koya Yuasa, Yuki Sera, Tatsuhiro A novel dynamic robotic moving phantom system for patient‐specific quality assurance in real‐time tumor‐tracking radiotherapy |
title | A novel dynamic robotic moving phantom system for patient‐specific quality assurance in real‐time tumor‐tracking radiotherapy |
title_full | A novel dynamic robotic moving phantom system for patient‐specific quality assurance in real‐time tumor‐tracking radiotherapy |
title_fullStr | A novel dynamic robotic moving phantom system for patient‐specific quality assurance in real‐time tumor‐tracking radiotherapy |
title_full_unstemmed | A novel dynamic robotic moving phantom system for patient‐specific quality assurance in real‐time tumor‐tracking radiotherapy |
title_short | A novel dynamic robotic moving phantom system for patient‐specific quality assurance in real‐time tumor‐tracking radiotherapy |
title_sort | novel dynamic robotic moving phantom system for patient‐specific quality assurance in real‐time tumor‐tracking radiotherapy |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7386190/ https://www.ncbi.nlm.nih.gov/pubmed/32281265 http://dx.doi.org/10.1002/acm2.12876 |
work_keys_str_mv | AT shiinokitakehiro anoveldynamicroboticmovingphantomsystemforpatientspecificqualityassuranceinrealtimetumortrackingradiotherapy AT fujiifumitake anoveldynamicroboticmovingphantomsystemforpatientspecificqualityassuranceinrealtimetumortrackingradiotherapy AT fujimotokoya anoveldynamicroboticmovingphantomsystemforpatientspecificqualityassuranceinrealtimetumortrackingradiotherapy AT yuasayuki anoveldynamicroboticmovingphantomsystemforpatientspecificqualityassuranceinrealtimetumortrackingradiotherapy AT seratatsuhiro anoveldynamicroboticmovingphantomsystemforpatientspecificqualityassuranceinrealtimetumortrackingradiotherapy AT shiinokitakehiro noveldynamicroboticmovingphantomsystemforpatientspecificqualityassuranceinrealtimetumortrackingradiotherapy AT fujiifumitake noveldynamicroboticmovingphantomsystemforpatientspecificqualityassuranceinrealtimetumortrackingradiotherapy AT fujimotokoya noveldynamicroboticmovingphantomsystemforpatientspecificqualityassuranceinrealtimetumortrackingradiotherapy AT yuasayuki noveldynamicroboticmovingphantomsystemforpatientspecificqualityassuranceinrealtimetumortrackingradiotherapy AT seratatsuhiro noveldynamicroboticmovingphantomsystemforpatientspecificqualityassuranceinrealtimetumortrackingradiotherapy |