Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews

BACKGROUND: Titanium miniscrews are used at an ever-increasing rate to provide orthodontic anchorage. The aim of this study was to evaluate the mechanical performance of miniscrews after dry and steam sterilization. MATERIALS AND METHODS: In this experimental study, a total of 72 miniscrews from two...

Descripción completa

Detalles Bibliográficos
Autores principales: Alavi, Shiva, Asadi, Farnaz, Raji, Seyed Amir Hossein, Samie, Soroor
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7386375/
https://www.ncbi.nlm.nih.gov/pubmed/32774800
_version_ 1783563940470456320
author Alavi, Shiva
Asadi, Farnaz
Raji, Seyed Amir Hossein
Samie, Soroor
author_facet Alavi, Shiva
Asadi, Farnaz
Raji, Seyed Amir Hossein
Samie, Soroor
author_sort Alavi, Shiva
collection PubMed
description BACKGROUND: Titanium miniscrews are used at an ever-increasing rate to provide orthodontic anchorage. The aim of this study was to evaluate the mechanical performance of miniscrews after dry and steam sterilization. MATERIALS AND METHODS: In this experimental study, a total of 72 miniscrews from two different manufacturers with a diameter of 1.6 mm and height of 8 mm were divided into six groups (n = 12). One group of screws from each manufacturer was considered as the control group; the second underwent steam sterilization; and the last group was subjected to dry sterilization. Insertion and fracture torques of each miniscrew were assessed by a torque tester. Data were analyzed using the Kruskal–Wallis and Mann–Whitney tests (P < 0.05). RESULTS: For Jeil miniscrew, no statistically significant differences were detected between the steam-sterilized and control groups in their insertion torques (P > 0.05). There was a statistically significant difference between the steam sterilized, dry sterilized and control groups with respect to their fracture torque (P < 0.001). For Hubit miniscrew, there were no significant differences between steam sterilized, dry sterilized and control groups in their insertion torque (P > 0.05) and between steam sterilized and control groups with respect to their fracture torque (P > 0.05). There were significant differences in the mean values of insertion and fracture torques between the two different manufacturers (P < 0.001). CONCLUSION: Steam sterilization had no detrimental effects on torque values of miniscrews, but dry heat sterilization affected their mechanical properties.
format Online
Article
Text
id pubmed-7386375
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-73863752020-08-07 Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews Alavi, Shiva Asadi, Farnaz Raji, Seyed Amir Hossein Samie, Soroor Dent Res J (Isfahan) Original Article BACKGROUND: Titanium miniscrews are used at an ever-increasing rate to provide orthodontic anchorage. The aim of this study was to evaluate the mechanical performance of miniscrews after dry and steam sterilization. MATERIALS AND METHODS: In this experimental study, a total of 72 miniscrews from two different manufacturers with a diameter of 1.6 mm and height of 8 mm were divided into six groups (n = 12). One group of screws from each manufacturer was considered as the control group; the second underwent steam sterilization; and the last group was subjected to dry sterilization. Insertion and fracture torques of each miniscrew were assessed by a torque tester. Data were analyzed using the Kruskal–Wallis and Mann–Whitney tests (P < 0.05). RESULTS: For Jeil miniscrew, no statistically significant differences were detected between the steam-sterilized and control groups in their insertion torques (P > 0.05). There was a statistically significant difference between the steam sterilized, dry sterilized and control groups with respect to their fracture torque (P < 0.001). For Hubit miniscrew, there were no significant differences between steam sterilized, dry sterilized and control groups in their insertion torque (P > 0.05) and between steam sterilized and control groups with respect to their fracture torque (P > 0.05). There were significant differences in the mean values of insertion and fracture torques between the two different manufacturers (P < 0.001). CONCLUSION: Steam sterilization had no detrimental effects on torque values of miniscrews, but dry heat sterilization affected their mechanical properties. Wolters Kluwer - Medknow 2020-05-23 /pmc/articles/PMC7386375/ /pubmed/32774800 Text en Copyright: © 2020 Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Alavi, Shiva
Asadi, Farnaz
Raji, Seyed Amir Hossein
Samie, Soroor
Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews
title Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews
title_full Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews
title_fullStr Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews
title_full_unstemmed Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews
title_short Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews
title_sort effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7386375/
https://www.ncbi.nlm.nih.gov/pubmed/32774800
work_keys_str_mv AT alavishiva effectofsteamanddryheatsterilizationontheinsertionandfracturetorqueoforthodonticminiscrews
AT asadifarnaz effectofsteamanddryheatsterilizationontheinsertionandfracturetorqueoforthodonticminiscrews
AT rajiseyedamirhossein effectofsteamanddryheatsterilizationontheinsertionandfracturetorqueoforthodonticminiscrews
AT samiesoroor effectofsteamanddryheatsterilizationontheinsertionandfracturetorqueoforthodonticminiscrews