Cargando…
Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews
BACKGROUND: Titanium miniscrews are used at an ever-increasing rate to provide orthodontic anchorage. The aim of this study was to evaluate the mechanical performance of miniscrews after dry and steam sterilization. MATERIALS AND METHODS: In this experimental study, a total of 72 miniscrews from two...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7386375/ https://www.ncbi.nlm.nih.gov/pubmed/32774800 |
_version_ | 1783563940470456320 |
---|---|
author | Alavi, Shiva Asadi, Farnaz Raji, Seyed Amir Hossein Samie, Soroor |
author_facet | Alavi, Shiva Asadi, Farnaz Raji, Seyed Amir Hossein Samie, Soroor |
author_sort | Alavi, Shiva |
collection | PubMed |
description | BACKGROUND: Titanium miniscrews are used at an ever-increasing rate to provide orthodontic anchorage. The aim of this study was to evaluate the mechanical performance of miniscrews after dry and steam sterilization. MATERIALS AND METHODS: In this experimental study, a total of 72 miniscrews from two different manufacturers with a diameter of 1.6 mm and height of 8 mm were divided into six groups (n = 12). One group of screws from each manufacturer was considered as the control group; the second underwent steam sterilization; and the last group was subjected to dry sterilization. Insertion and fracture torques of each miniscrew were assessed by a torque tester. Data were analyzed using the Kruskal–Wallis and Mann–Whitney tests (P < 0.05). RESULTS: For Jeil miniscrew, no statistically significant differences were detected between the steam-sterilized and control groups in their insertion torques (P > 0.05). There was a statistically significant difference between the steam sterilized, dry sterilized and control groups with respect to their fracture torque (P < 0.001). For Hubit miniscrew, there were no significant differences between steam sterilized, dry sterilized and control groups in their insertion torque (P > 0.05) and between steam sterilized and control groups with respect to their fracture torque (P > 0.05). There were significant differences in the mean values of insertion and fracture torques between the two different manufacturers (P < 0.001). CONCLUSION: Steam sterilization had no detrimental effects on torque values of miniscrews, but dry heat sterilization affected their mechanical properties. |
format | Online Article Text |
id | pubmed-7386375 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-73863752020-08-07 Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews Alavi, Shiva Asadi, Farnaz Raji, Seyed Amir Hossein Samie, Soroor Dent Res J (Isfahan) Original Article BACKGROUND: Titanium miniscrews are used at an ever-increasing rate to provide orthodontic anchorage. The aim of this study was to evaluate the mechanical performance of miniscrews after dry and steam sterilization. MATERIALS AND METHODS: In this experimental study, a total of 72 miniscrews from two different manufacturers with a diameter of 1.6 mm and height of 8 mm were divided into six groups (n = 12). One group of screws from each manufacturer was considered as the control group; the second underwent steam sterilization; and the last group was subjected to dry sterilization. Insertion and fracture torques of each miniscrew were assessed by a torque tester. Data were analyzed using the Kruskal–Wallis and Mann–Whitney tests (P < 0.05). RESULTS: For Jeil miniscrew, no statistically significant differences were detected between the steam-sterilized and control groups in their insertion torques (P > 0.05). There was a statistically significant difference between the steam sterilized, dry sterilized and control groups with respect to their fracture torque (P < 0.001). For Hubit miniscrew, there were no significant differences between steam sterilized, dry sterilized and control groups in their insertion torque (P > 0.05) and between steam sterilized and control groups with respect to their fracture torque (P > 0.05). There were significant differences in the mean values of insertion and fracture torques between the two different manufacturers (P < 0.001). CONCLUSION: Steam sterilization had no detrimental effects on torque values of miniscrews, but dry heat sterilization affected their mechanical properties. Wolters Kluwer - Medknow 2020-05-23 /pmc/articles/PMC7386375/ /pubmed/32774800 Text en Copyright: © 2020 Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Alavi, Shiva Asadi, Farnaz Raji, Seyed Amir Hossein Samie, Soroor Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews |
title | Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews |
title_full | Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews |
title_fullStr | Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews |
title_full_unstemmed | Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews |
title_short | Effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews |
title_sort | effect of steam and dry heat sterilization on the insertion and fracture torque of orthodontic miniscrews |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7386375/ https://www.ncbi.nlm.nih.gov/pubmed/32774800 |
work_keys_str_mv | AT alavishiva effectofsteamanddryheatsterilizationontheinsertionandfracturetorqueoforthodonticminiscrews AT asadifarnaz effectofsteamanddryheatsterilizationontheinsertionandfracturetorqueoforthodonticminiscrews AT rajiseyedamirhossein effectofsteamanddryheatsterilizationontheinsertionandfracturetorqueoforthodonticminiscrews AT samiesoroor effectofsteamanddryheatsterilizationontheinsertionandfracturetorqueoforthodonticminiscrews |