Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer

Because dogs tolerate conventional rectal temperature measurements poorly, a calibrated infrared thermometer was tested for assessing canine body surface temperature. Body surface temperature of 204 dogs was estimated on various sites (digit, snout, axilla, eye, gum, inguinal region, and anal verge)...

Descripción completa

Detalles Bibliográficos
Autores principales: Cugmas, Blaž, Šušterič, Primož, Gorenjec, Nina Ružić, Plavec, Tanja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7386665/
https://www.ncbi.nlm.nih.gov/pubmed/32734121
http://dx.doi.org/10.1016/j.vas.2020.100120
_version_ 1783563991925129216
author Cugmas, Blaž
Šušterič, Primož
Gorenjec, Nina Ružić
Plavec, Tanja
author_facet Cugmas, Blaž
Šušterič, Primož
Gorenjec, Nina Ružić
Plavec, Tanja
author_sort Cugmas, Blaž
collection PubMed
description Because dogs tolerate conventional rectal temperature measurements poorly, a calibrated infrared thermometer was tested for assessing canine body surface temperature. Body surface temperature of 204 dogs was estimated on various sites (digit, snout, axilla, eye, gum, inguinal region, and anal verge). Having rectal temperature as the gold standard, temperature difference, Spearman's correlation coefficient, hyperthermia and hypothermia detection sensitivity and specificity, and stress response score was calculated for each measurement site. Although the canine body surface temperature was considerably lower than the rectal temperature, there was a moderate correlation between both temperatures. Spearman's coefficients were 0.60 (p < 0.001) for the inguinal region with a single operator and 0.50 (p < 0.001) for the gum with multiple operators. Measurement site on the gum additionally guaranteed hyperthermia detection sensitivity and specificity up to 90.0% (95% CI: [66.7 100]) and 78.6% (95% CI: [71.6 85.2]), respectively. Measurements with the infrared thermometer provoked a statistically significant lower stress response (mean stress scores between 1.89 and 2.48/5) compared to the contact rectal measurements (stress score of 3.06/5). To conclude, the correct body surface temperature measurement should include a calibrated thermometer, reliable sampling, and the control of external factors such as ambient temperature influence. The transformation of body surface temperature to the recognized rectal temperature interval allows more straightforward data interpretation. The gum temperature exhibited the best clinical potential since the differences to rectal temperatures were below 1°C, and hyperthermia was detected with the sensitivity of up to 90%.
format Online
Article
Text
id pubmed-7386665
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-73866652020-07-29 Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer Cugmas, Blaž Šušterič, Primož Gorenjec, Nina Ružić Plavec, Tanja Vet Anim Sci Article Because dogs tolerate conventional rectal temperature measurements poorly, a calibrated infrared thermometer was tested for assessing canine body surface temperature. Body surface temperature of 204 dogs was estimated on various sites (digit, snout, axilla, eye, gum, inguinal region, and anal verge). Having rectal temperature as the gold standard, temperature difference, Spearman's correlation coefficient, hyperthermia and hypothermia detection sensitivity and specificity, and stress response score was calculated for each measurement site. Although the canine body surface temperature was considerably lower than the rectal temperature, there was a moderate correlation between both temperatures. Spearman's coefficients were 0.60 (p < 0.001) for the inguinal region with a single operator and 0.50 (p < 0.001) for the gum with multiple operators. Measurement site on the gum additionally guaranteed hyperthermia detection sensitivity and specificity up to 90.0% (95% CI: [66.7 100]) and 78.6% (95% CI: [71.6 85.2]), respectively. Measurements with the infrared thermometer provoked a statistically significant lower stress response (mean stress scores between 1.89 and 2.48/5) compared to the contact rectal measurements (stress score of 3.06/5). To conclude, the correct body surface temperature measurement should include a calibrated thermometer, reliable sampling, and the control of external factors such as ambient temperature influence. The transformation of body surface temperature to the recognized rectal temperature interval allows more straightforward data interpretation. The gum temperature exhibited the best clinical potential since the differences to rectal temperatures were below 1°C, and hyperthermia was detected with the sensitivity of up to 90%. Elsevier 2020-05-16 /pmc/articles/PMC7386665/ /pubmed/32734121 http://dx.doi.org/10.1016/j.vas.2020.100120 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Cugmas, Blaž
Šušterič, Primož
Gorenjec, Nina Ružić
Plavec, Tanja
Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer
title Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer
title_full Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer
title_fullStr Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer
title_full_unstemmed Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer
title_short Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer
title_sort comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7386665/
https://www.ncbi.nlm.nih.gov/pubmed/32734121
http://dx.doi.org/10.1016/j.vas.2020.100120
work_keys_str_mv AT cugmasblaz comparisonbetweenrectalandbodysurfacetemperatureindogsbythecalibratedinfraredthermometer
AT sustericprimoz comparisonbetweenrectalandbodysurfacetemperatureindogsbythecalibratedinfraredthermometer
AT gorenjecninaruzic comparisonbetweenrectalandbodysurfacetemperatureindogsbythecalibratedinfraredthermometer
AT plavectanja comparisonbetweenrectalandbodysurfacetemperatureindogsbythecalibratedinfraredthermometer