Cargando…

Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: An observational study of our initial experiences

To evaluate the value of a breast computed tomography (CT) (B-CT) in assessing breast density, pathologies and implant integrity in women with breast implants. This retrospective study was approved by the local ethics committee. B-CT images of 21 women with implants (silicone/saline; 20 bilateral, 1...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruby, Lisa, Shim, Sojin, Berger, Nicole, Marcon, Magda, Frauenfelder, Thomas, Boss, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7387031/
https://www.ncbi.nlm.nih.gov/pubmed/32791669
http://dx.doi.org/10.1097/MD.0000000000020797
_version_ 1783564060768337920
author Ruby, Lisa
Shim, Sojin
Berger, Nicole
Marcon, Magda
Frauenfelder, Thomas
Boss, Andreas
author_facet Ruby, Lisa
Shim, Sojin
Berger, Nicole
Marcon, Magda
Frauenfelder, Thomas
Boss, Andreas
author_sort Ruby, Lisa
collection PubMed
description To evaluate the value of a breast computed tomography (CT) (B-CT) in assessing breast density, pathologies and implant integrity in women with breast implants. This retrospective study was approved by the local ethics committee. B-CT images of 21 women with implants (silicone/saline; 20 bilateral, 1 unilateral) who underwent opportunistic screening or diagnostic bilateral B-CT were included. Breast density, implant integrity, extensive capsular fibrosis, soft tissue lesions and micro-/macrocalcifications were rated. In 18 of the 21 women, an additional ultrasound and in two patients breast magnetic resonance imaging was available for comparison. The average dose was calculated for each breast using verified Monte Carlo simulations on 3D image data sets. Breast density was nearly completely fatty (ACR a) in two patients, scattered fibroglandular (ACR b) in five, heterogeneously dense (ACR c) in ten and very dense (ACR d) in four women. In three women showed a unilateral positive Linguine sign indicative of an inner capsule rupture. Extensive capsular fibrosis was found in three women. In three women, soft tissue lesions were depicted, which revealed to be cysts (n = 2) and lymph nodes (n = 1) on subsequent sonography. Diffuse, non-clustered microcalcifications were found in nine women. Eleven women showed cutaneous or intramammary macrocalcifications. Average dose was 6.45 mGy (range 5.81–7.28 mGy). In women with implants, B-CT presents a promising modality for evaluating breast density, implant integrity, extensive capsular fibrosis, soft tissue lesions and micro-/macrocalcifications without the need of breast compression utilizing a lower dose compared to doses reported for conventional four-view mammography.
format Online
Article
Text
id pubmed-7387031
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-73870312020-08-05 Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: An observational study of our initial experiences Ruby, Lisa Shim, Sojin Berger, Nicole Marcon, Magda Frauenfelder, Thomas Boss, Andreas Medicine (Baltimore) 6800 To evaluate the value of a breast computed tomography (CT) (B-CT) in assessing breast density, pathologies and implant integrity in women with breast implants. This retrospective study was approved by the local ethics committee. B-CT images of 21 women with implants (silicone/saline; 20 bilateral, 1 unilateral) who underwent opportunistic screening or diagnostic bilateral B-CT were included. Breast density, implant integrity, extensive capsular fibrosis, soft tissue lesions and micro-/macrocalcifications were rated. In 18 of the 21 women, an additional ultrasound and in two patients breast magnetic resonance imaging was available for comparison. The average dose was calculated for each breast using verified Monte Carlo simulations on 3D image data sets. Breast density was nearly completely fatty (ACR a) in two patients, scattered fibroglandular (ACR b) in five, heterogeneously dense (ACR c) in ten and very dense (ACR d) in four women. In three women showed a unilateral positive Linguine sign indicative of an inner capsule rupture. Extensive capsular fibrosis was found in three women. In three women, soft tissue lesions were depicted, which revealed to be cysts (n = 2) and lymph nodes (n = 1) on subsequent sonography. Diffuse, non-clustered microcalcifications were found in nine women. Eleven women showed cutaneous or intramammary macrocalcifications. Average dose was 6.45 mGy (range 5.81–7.28 mGy). In women with implants, B-CT presents a promising modality for evaluating breast density, implant integrity, extensive capsular fibrosis, soft tissue lesions and micro-/macrocalcifications without the need of breast compression utilizing a lower dose compared to doses reported for conventional four-view mammography. Wolters Kluwer Health 2020-07-24 /pmc/articles/PMC7387031/ /pubmed/32791669 http://dx.doi.org/10.1097/MD.0000000000020797 Text en Copyright © 2020 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0
spellingShingle 6800
Ruby, Lisa
Shim, Sojin
Berger, Nicole
Marcon, Magda
Frauenfelder, Thomas
Boss, Andreas
Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: An observational study of our initial experiences
title Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: An observational study of our initial experiences
title_full Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: An observational study of our initial experiences
title_fullStr Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: An observational study of our initial experiences
title_full_unstemmed Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: An observational study of our initial experiences
title_short Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: An observational study of our initial experiences
title_sort diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: an observational study of our initial experiences
topic 6800
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7387031/
https://www.ncbi.nlm.nih.gov/pubmed/32791669
http://dx.doi.org/10.1097/MD.0000000000020797
work_keys_str_mv AT rubylisa diagnosticvalueofaspiralbreastcomputedtomographysystemequippedwithphotoncountingdetectortechnologyinpatientswithimplantsanobservationalstudyofourinitialexperiences
AT shimsojin diagnosticvalueofaspiralbreastcomputedtomographysystemequippedwithphotoncountingdetectortechnologyinpatientswithimplantsanobservationalstudyofourinitialexperiences
AT bergernicole diagnosticvalueofaspiralbreastcomputedtomographysystemequippedwithphotoncountingdetectortechnologyinpatientswithimplantsanobservationalstudyofourinitialexperiences
AT marconmagda diagnosticvalueofaspiralbreastcomputedtomographysystemequippedwithphotoncountingdetectortechnologyinpatientswithimplantsanobservationalstudyofourinitialexperiences
AT frauenfelderthomas diagnosticvalueofaspiralbreastcomputedtomographysystemequippedwithphotoncountingdetectortechnologyinpatientswithimplantsanobservationalstudyofourinitialexperiences
AT bossandreas diagnosticvalueofaspiralbreastcomputedtomographysystemequippedwithphotoncountingdetectortechnologyinpatientswithimplantsanobservationalstudyofourinitialexperiences