Cargando…
Design of a loading system for cyclic test on sutured organs
The design of loading systems to test biologic samples is often challenging, due to shape variability and non-conventional loading set-ups. In addition to this, large economic investments would not be justified since the loading set up is usually designed for one single or for a limited range of app...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7387823/ https://www.ncbi.nlm.nih.gov/pubmed/32742943 http://dx.doi.org/10.1016/j.mex.2020.100988 |
_version_ | 1783564202846191616 |
---|---|
author | Pascoletti, Giulia Pressanto, Maria Chiara Putame, Giovanni Terzini, Mara Franceschini, Giordano Zanetti, Elisabetta M. |
author_facet | Pascoletti, Giulia Pressanto, Maria Chiara Putame, Giovanni Terzini, Mara Franceschini, Giordano Zanetti, Elisabetta M. |
author_sort | Pascoletti, Giulia |
collection | PubMed |
description | The design of loading systems to test biologic samples is often challenging, due to shape variability and non-conventional loading set-ups. In addition to this, large economic investments would not be justified since the loading set up is usually designed for one single or for a limited range of applications. The object of this work is the development of a loading set-up finalised to on-site testing of sutures whose main function is applying a localised tensile load. The main challenges of this design process can be so summarized: • Applying cyclic tensile loads on the suture wire, mimicking the physiologic condition where both suture anchorage points have a certain compliance; • Designing a loading system as versatile as possible, in order to be able to accommodate organs with different geometries and sizes; • Keeping low both the complexity and costs of realization. All these considerations and the design calculi are here reported in detail, discussing the novelty of the system, and its main advantages. |
format | Online Article Text |
id | pubmed-7387823 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-73878232020-07-31 Design of a loading system for cyclic test on sutured organs Pascoletti, Giulia Pressanto, Maria Chiara Putame, Giovanni Terzini, Mara Franceschini, Giordano Zanetti, Elisabetta M. MethodsX Engineering The design of loading systems to test biologic samples is often challenging, due to shape variability and non-conventional loading set-ups. In addition to this, large economic investments would not be justified since the loading set up is usually designed for one single or for a limited range of applications. The object of this work is the development of a loading set-up finalised to on-site testing of sutures whose main function is applying a localised tensile load. The main challenges of this design process can be so summarized: • Applying cyclic tensile loads on the suture wire, mimicking the physiologic condition where both suture anchorage points have a certain compliance; • Designing a loading system as versatile as possible, in order to be able to accommodate organs with different geometries and sizes; • Keeping low both the complexity and costs of realization. All these considerations and the design calculi are here reported in detail, discussing the novelty of the system, and its main advantages. Elsevier 2020-07-08 /pmc/articles/PMC7387823/ /pubmed/32742943 http://dx.doi.org/10.1016/j.mex.2020.100988 Text en © 2020 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Engineering Pascoletti, Giulia Pressanto, Maria Chiara Putame, Giovanni Terzini, Mara Franceschini, Giordano Zanetti, Elisabetta M. Design of a loading system for cyclic test on sutured organs |
title | Design of a loading system for cyclic test on sutured organs |
title_full | Design of a loading system for cyclic test on sutured organs |
title_fullStr | Design of a loading system for cyclic test on sutured organs |
title_full_unstemmed | Design of a loading system for cyclic test on sutured organs |
title_short | Design of a loading system for cyclic test on sutured organs |
title_sort | design of a loading system for cyclic test on sutured organs |
topic | Engineering |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7387823/ https://www.ncbi.nlm.nih.gov/pubmed/32742943 http://dx.doi.org/10.1016/j.mex.2020.100988 |
work_keys_str_mv | AT pascolettigiulia designofaloadingsystemforcyclictestonsuturedorgans AT pressantomariachiara designofaloadingsystemforcyclictestonsuturedorgans AT putamegiovanni designofaloadingsystemforcyclictestonsuturedorgans AT terzinimara designofaloadingsystemforcyclictestonsuturedorgans AT franceschinigiordano designofaloadingsystemforcyclictestonsuturedorgans AT zanettielisabettam designofaloadingsystemforcyclictestonsuturedorgans |