Cargando…

Performance Evaluation of Mixed Reality Display for Guidance During Transcatheter Cardiac Mapping and Ablation

Cardiac electrophysiology procedures present the physician with a wealth of 3D information, typically presented on fixed 2D monitors. New developments in wearable mixed reality displays offer the potential to simplify and enhance 3D visualization while providing hands-free, dynamic control of device...

Descripción completa

Detalles Bibliográficos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IEEE 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7390021/
https://www.ncbi.nlm.nih.gov/pubmed/32742821
http://dx.doi.org/10.1109/JTEHM.2020.3007031
_version_ 1783564429605994496
collection PubMed
description Cardiac electrophysiology procedures present the physician with a wealth of 3D information, typically presented on fixed 2D monitors. New developments in wearable mixed reality displays offer the potential to simplify and enhance 3D visualization while providing hands-free, dynamic control of devices within the procedure room. Objective: This work aims to evaluate the performance and quality of a mixed reality system designed for intraprocedural use in cardiac electrophysiology. Method: The Enhanced Electrophysiology Visualization and Interaction System (ĒLVIS) mixed reality system performance criteria, including image quality, hardware performance, and usability were evaluated using existing display validation procedures adapted to the electrophysiology specific use case. Additional performance and user validation were performed through a 10 patient, in-human observational study, the Engineering ĒLVIS (E2) Study. Results: The ĒLVIS system achieved acceptable frame rate, latency, and battery runtime with acceptable dynamic range and depth distortion as well as minimal geometric distortion. Bench testing results corresponded with physician feedback in the observational study, and potential improvements in geometric understanding were noted. Conclusion: The ĒLVIS system, based on current commercially available mixed reality hardware, is capable of meeting the hardware performance, image quality, and usability requirements of the electroanatomic mapping display for intraprocedural, real-time use in electrophysiology procedures. Verifying off the shelf mixed reality hardware for specific clinical use can accelerate the adoption of this transformative technology and provide novel visualization, understanding, and control of clinically relevant data in real-time.
format Online
Article
Text
id pubmed-7390021
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher IEEE
record_format MEDLINE/PubMed
spelling pubmed-73900212020-07-30 Performance Evaluation of Mixed Reality Display for Guidance During Transcatheter Cardiac Mapping and Ablation IEEE J Transl Eng Health Med Article Cardiac electrophysiology procedures present the physician with a wealth of 3D information, typically presented on fixed 2D monitors. New developments in wearable mixed reality displays offer the potential to simplify and enhance 3D visualization while providing hands-free, dynamic control of devices within the procedure room. Objective: This work aims to evaluate the performance and quality of a mixed reality system designed for intraprocedural use in cardiac electrophysiology. Method: The Enhanced Electrophysiology Visualization and Interaction System (ĒLVIS) mixed reality system performance criteria, including image quality, hardware performance, and usability were evaluated using existing display validation procedures adapted to the electrophysiology specific use case. Additional performance and user validation were performed through a 10 patient, in-human observational study, the Engineering ĒLVIS (E2) Study. Results: The ĒLVIS system achieved acceptable frame rate, latency, and battery runtime with acceptable dynamic range and depth distortion as well as minimal geometric distortion. Bench testing results corresponded with physician feedback in the observational study, and potential improvements in geometric understanding were noted. Conclusion: The ĒLVIS system, based on current commercially available mixed reality hardware, is capable of meeting the hardware performance, image quality, and usability requirements of the electroanatomic mapping display for intraprocedural, real-time use in electrophysiology procedures. Verifying off the shelf mixed reality hardware for specific clinical use can accelerate the adoption of this transformative technology and provide novel visualization, understanding, and control of clinically relevant data in real-time. IEEE 2020-07-03 /pmc/articles/PMC7390021/ /pubmed/32742821 http://dx.doi.org/10.1109/JTEHM.2020.3007031 Text en https://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Performance Evaluation of Mixed Reality Display for Guidance During Transcatheter Cardiac Mapping and Ablation
title Performance Evaluation of Mixed Reality Display for Guidance During Transcatheter Cardiac Mapping and Ablation
title_full Performance Evaluation of Mixed Reality Display for Guidance During Transcatheter Cardiac Mapping and Ablation
title_fullStr Performance Evaluation of Mixed Reality Display for Guidance During Transcatheter Cardiac Mapping and Ablation
title_full_unstemmed Performance Evaluation of Mixed Reality Display for Guidance During Transcatheter Cardiac Mapping and Ablation
title_short Performance Evaluation of Mixed Reality Display for Guidance During Transcatheter Cardiac Mapping and Ablation
title_sort performance evaluation of mixed reality display for guidance during transcatheter cardiac mapping and ablation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7390021/
https://www.ncbi.nlm.nih.gov/pubmed/32742821
http://dx.doi.org/10.1109/JTEHM.2020.3007031
work_keys_str_mv AT performanceevaluationofmixedrealitydisplayforguidanceduringtranscathetercardiacmappingandablation
AT performanceevaluationofmixedrealitydisplayforguidanceduringtranscathetercardiacmappingandablation
AT performanceevaluationofmixedrealitydisplayforguidanceduringtranscathetercardiacmappingandablation
AT performanceevaluationofmixedrealitydisplayforguidanceduringtranscathetercardiacmappingandablation
AT performanceevaluationofmixedrealitydisplayforguidanceduringtranscathetercardiacmappingandablation
AT performanceevaluationofmixedrealitydisplayforguidanceduringtranscathetercardiacmappingandablation