Cargando…

Consistency of superb microvascular imaging and contrast-enhanced ultrasonography in detection of intraplaque neovascularization: A meta-analysis

This meta-analysis assesses the consistency of superb microvascular imaging (SMI) and contrast-enhanced ultrasonography (CEUS) in detecting intraplaque neovascularization (IPN). We searched PubMed, Web of Science, the Cochrane Library, and CBM databases. A meta-analysis was conducted using STATA ver...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Fang, Wang, Cong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7392312/
https://www.ncbi.nlm.nih.gov/pubmed/32730304
http://dx.doi.org/10.1371/journal.pone.0230937
_version_ 1783564822754885632
author Yang, Fang
Wang, Cong
author_facet Yang, Fang
Wang, Cong
author_sort Yang, Fang
collection PubMed
description This meta-analysis assesses the consistency of superb microvascular imaging (SMI) and contrast-enhanced ultrasonography (CEUS) in detecting intraplaque neovascularization (IPN). We searched PubMed, Web of Science, the Cochrane Library, and CBM databases. A meta-analysis was conducted using STATA version 15.1 software. We calculated the pooled Kappa index. Ten studies that met all of the inclusion criteria were included in this meta-analysis. A total of 608 carotid plaques were assessed through both SMI and CEUS. The pooled summary Kappa index was 0.743 (95% confidence interval (CI) = 0.696–0.790) with statistical significance (z = 31.14, P < 0.01). We found no evidence of publication bias (t = −1.21, P = 0.261). Our meta-analysis indicates that SMI and CEUS display a good consistency in detecting the IPN of carotid plaque; that is, SMI ultrasound may be a promising alternative to CEUS for detecting the IPN of carotid plaque.
format Online
Article
Text
id pubmed-7392312
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-73923122020-08-05 Consistency of superb microvascular imaging and contrast-enhanced ultrasonography in detection of intraplaque neovascularization: A meta-analysis Yang, Fang Wang, Cong PLoS One Research Article This meta-analysis assesses the consistency of superb microvascular imaging (SMI) and contrast-enhanced ultrasonography (CEUS) in detecting intraplaque neovascularization (IPN). We searched PubMed, Web of Science, the Cochrane Library, and CBM databases. A meta-analysis was conducted using STATA version 15.1 software. We calculated the pooled Kappa index. Ten studies that met all of the inclusion criteria were included in this meta-analysis. A total of 608 carotid plaques were assessed through both SMI and CEUS. The pooled summary Kappa index was 0.743 (95% confidence interval (CI) = 0.696–0.790) with statistical significance (z = 31.14, P < 0.01). We found no evidence of publication bias (t = −1.21, P = 0.261). Our meta-analysis indicates that SMI and CEUS display a good consistency in detecting the IPN of carotid plaque; that is, SMI ultrasound may be a promising alternative to CEUS for detecting the IPN of carotid plaque. Public Library of Science 2020-07-30 /pmc/articles/PMC7392312/ /pubmed/32730304 http://dx.doi.org/10.1371/journal.pone.0230937 Text en © 2020 Yang, Wang http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Yang, Fang
Wang, Cong
Consistency of superb microvascular imaging and contrast-enhanced ultrasonography in detection of intraplaque neovascularization: A meta-analysis
title Consistency of superb microvascular imaging and contrast-enhanced ultrasonography in detection of intraplaque neovascularization: A meta-analysis
title_full Consistency of superb microvascular imaging and contrast-enhanced ultrasonography in detection of intraplaque neovascularization: A meta-analysis
title_fullStr Consistency of superb microvascular imaging and contrast-enhanced ultrasonography in detection of intraplaque neovascularization: A meta-analysis
title_full_unstemmed Consistency of superb microvascular imaging and contrast-enhanced ultrasonography in detection of intraplaque neovascularization: A meta-analysis
title_short Consistency of superb microvascular imaging and contrast-enhanced ultrasonography in detection of intraplaque neovascularization: A meta-analysis
title_sort consistency of superb microvascular imaging and contrast-enhanced ultrasonography in detection of intraplaque neovascularization: a meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7392312/
https://www.ncbi.nlm.nih.gov/pubmed/32730304
http://dx.doi.org/10.1371/journal.pone.0230937
work_keys_str_mv AT yangfang consistencyofsuperbmicrovascularimagingandcontrastenhancedultrasonographyindetectionofintraplaqueneovascularizationametaanalysis
AT wangcong consistencyofsuperbmicrovascularimagingandcontrastenhancedultrasonographyindetectionofintraplaqueneovascularizationametaanalysis