Immediate Implant Placement in Non-Infected Sockets versus Infected Sockets: a Systematic Review and Meta-Analysis

OBJECTIVES: The aim of this systematic review is to compare immediate implant placement in infected extraction sockets with non-infected extraction sockets in terms of implant survival and function. MATERIAL AND METHODS: An electronic search was conducted in PubMed, ScienceDirect, ISI Web of Knowled...

Descripción completa

Detalles Bibliográficos
Autores principales: Saijeva, Aza, Juodzbalys, Gintaras
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Stilus Optimus 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7393932/
https://www.ncbi.nlm.nih.gov/pubmed/32760474
http://dx.doi.org/10.5037/jomr.2020.11201
_version_ 1783565134394818560
author Saijeva, Aza
Juodzbalys, Gintaras
author_facet Saijeva, Aza
Juodzbalys, Gintaras
author_sort Saijeva, Aza
collection PubMed
description OBJECTIVES: The aim of this systematic review is to compare immediate implant placement in infected extraction sockets with non-infected extraction sockets in terms of implant survival and function. MATERIAL AND METHODS: An electronic search was conducted in PubMed, ScienceDirect, ISI Web of Knowledge and Google Scholar between January 2010 and February 2020. Studies evaluating implant survival rate and main clinical parameters were included for a qualitative and quantitative analysis. RESULTS: In total, nine studies were included and a pool of 2281 sockets were analysed. Compared with the non-infected group, the infected group showed no significant differences in implant survival rates (risk ratio [RR] = 0.99; 95% confidence interval [CI] = 0.98 to 1; P = 0.08). No significant statistical differences were found in marginal bone level (mean difference [MD] = -0.03; 95% CI = -0.1 to 0.04; P = 0.41), marginal gingival level (MD = -0.07; 95% CI = -0.17 to 0.04; P = 0.23), probing depth (MD = 0.06; 95% CI = -0.24 to 0.36; P = 0.7), modified bleeding index (MD = -0.00162196; 95% CI = -0.09 to 0.09; P = 0.97) and slight but significant changes were seen in width of keratinized gingiva (MD = 0.25; 95% CI = -0.3 to 0.8; P = 0.38) between the groups at the latest follow-up. CONCLUSIONS: There were no significant difference in implant survival rates, marginal bone level, marginal gingival level, modified bleeding index and probing depth between infected sockets and non-infected sockets. However, slight but significant changes were seen in width of keratinized gingiva favouring the non-infected group.
format Online
Article
Text
id pubmed-7393932
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Stilus Optimus
record_format MEDLINE/PubMed
spelling pubmed-73939322020-08-04 Immediate Implant Placement in Non-Infected Sockets versus Infected Sockets: a Systematic Review and Meta-Analysis Saijeva, Aza Juodzbalys, Gintaras J Oral Maxillofac Res Literature Review OBJECTIVES: The aim of this systematic review is to compare immediate implant placement in infected extraction sockets with non-infected extraction sockets in terms of implant survival and function. MATERIAL AND METHODS: An electronic search was conducted in PubMed, ScienceDirect, ISI Web of Knowledge and Google Scholar between January 2010 and February 2020. Studies evaluating implant survival rate and main clinical parameters were included for a qualitative and quantitative analysis. RESULTS: In total, nine studies were included and a pool of 2281 sockets were analysed. Compared with the non-infected group, the infected group showed no significant differences in implant survival rates (risk ratio [RR] = 0.99; 95% confidence interval [CI] = 0.98 to 1; P = 0.08). No significant statistical differences were found in marginal bone level (mean difference [MD] = -0.03; 95% CI = -0.1 to 0.04; P = 0.41), marginal gingival level (MD = -0.07; 95% CI = -0.17 to 0.04; P = 0.23), probing depth (MD = 0.06; 95% CI = -0.24 to 0.36; P = 0.7), modified bleeding index (MD = -0.00162196; 95% CI = -0.09 to 0.09; P = 0.97) and slight but significant changes were seen in width of keratinized gingiva (MD = 0.25; 95% CI = -0.3 to 0.8; P = 0.38) between the groups at the latest follow-up. CONCLUSIONS: There were no significant difference in implant survival rates, marginal bone level, marginal gingival level, modified bleeding index and probing depth between infected sockets and non-infected sockets. However, slight but significant changes were seen in width of keratinized gingiva favouring the non-infected group. Stilus Optimus 2020-06-30 /pmc/articles/PMC7393932/ /pubmed/32760474 http://dx.doi.org/10.5037/jomr.2020.11201 Text en Copyright © Saijeva A, Juodzbalys G. Published in the JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH (http://www.ejomr.org), 30 June 2020. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article, first published in the JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH, distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 UnportedLicense (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work and is properly cited. The copyright, license information and link to the original publication on (http://www.ejomr.org) must be included.
spellingShingle Literature Review
Saijeva, Aza
Juodzbalys, Gintaras
Immediate Implant Placement in Non-Infected Sockets versus Infected Sockets: a Systematic Review and Meta-Analysis
title Immediate Implant Placement in Non-Infected Sockets versus Infected Sockets: a Systematic Review and Meta-Analysis
title_full Immediate Implant Placement in Non-Infected Sockets versus Infected Sockets: a Systematic Review and Meta-Analysis
title_fullStr Immediate Implant Placement in Non-Infected Sockets versus Infected Sockets: a Systematic Review and Meta-Analysis
title_full_unstemmed Immediate Implant Placement in Non-Infected Sockets versus Infected Sockets: a Systematic Review and Meta-Analysis
title_short Immediate Implant Placement in Non-Infected Sockets versus Infected Sockets: a Systematic Review and Meta-Analysis
title_sort immediate implant placement in non-infected sockets versus infected sockets: a systematic review and meta-analysis
topic Literature Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7393932/
https://www.ncbi.nlm.nih.gov/pubmed/32760474
http://dx.doi.org/10.5037/jomr.2020.11201
work_keys_str_mv AT saijevaaza immediateimplantplacementinnoninfectedsocketsversusinfectedsocketsasystematicreviewandmetaanalysis
AT juodzbalysgintaras immediateimplantplacementinnoninfectedsocketsversusinfectedsocketsasystematicreviewandmetaanalysis