Cargando…

Clinical outcomes of Ti-Ni shape-memory patella concentrator combined with cannulated compression screws in the treatment of C2 and C3 patella fracture: a retrospective study of 54 cases

BACKGROUND: Ti-Ni shape-memory patella concentrator (TNSMPC) has been designed as an alternative approach for fixation of patella fracture, which has some advantages like higher hardness, higher tenacity, better wearing resistance, excellent corrosion resistance and desired histocompatibility. The p...

Descripción completa

Detalles Bibliográficos
Autores principales: Yao, Chen, Sun, Jie, Wu, Jiancheng, Zhou, Zhenyu, Liu, Fan, Tao, Ran, Zhang, Yafeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7395425/
https://www.ncbi.nlm.nih.gov/pubmed/32736553
http://dx.doi.org/10.1186/s12891-020-03536-3
_version_ 1783565406351392768
author Yao, Chen
Sun, Jie
Wu, Jiancheng
Zhou, Zhenyu
Liu, Fan
Tao, Ran
Zhang, Yafeng
author_facet Yao, Chen
Sun, Jie
Wu, Jiancheng
Zhou, Zhenyu
Liu, Fan
Tao, Ran
Zhang, Yafeng
author_sort Yao, Chen
collection PubMed
description BACKGROUND: Ti-Ni shape-memory patella concentrator (TNSMPC) has been designed as an alternative approach for fixation of patella fracture, which has some advantages like higher hardness, higher tenacity, better wearing resistance, excellent corrosion resistance and desired histocompatibility. The present study was to investigate the efficiency of TNSMPC combined with cannulated compression screws in the treatment of comminuted patella fractures. METHODS: Between January 2014 and December 2017, 54 patients of C2 and C3 patella fractures underwent open reduction and internal fixation with TNSMPC combined with cannulated compression screws. All the patients got standard postoperative rehabilitation programs and were regularly followed up for at least 12 months after the operation. X-rays, knee functions and life quality were evaluated during the follow-up. RESULTS: All the patients achieved bone healing and recovery of knee function with low incidence of complications according to outcomes of X-rays and questionnaires. The average operation time and blood loss during surgery were 77.5 ± 25.12 min and 24.25 ± 4.70 ml respectively. The Knee Outcome Survey Activities of Daily Living Scale, the range of motion and the 36-item short-form heath survey after the operation were all improved. According to the Bostman’s criteria, the excellent to good rate was 92.6%. CONCLUSION: TNSMPC combined with cannulated compression screws is an effective internal fixation method for C2 and C3 patella fracture with excellent clinical outcomes. In addition, the operation does not increase extra technique difficulty or tissue damage relatively, which is worth promotion.
format Online
Article
Text
id pubmed-7395425
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-73954252020-08-05 Clinical outcomes of Ti-Ni shape-memory patella concentrator combined with cannulated compression screws in the treatment of C2 and C3 patella fracture: a retrospective study of 54 cases Yao, Chen Sun, Jie Wu, Jiancheng Zhou, Zhenyu Liu, Fan Tao, Ran Zhang, Yafeng BMC Musculoskelet Disord Research Article BACKGROUND: Ti-Ni shape-memory patella concentrator (TNSMPC) has been designed as an alternative approach for fixation of patella fracture, which has some advantages like higher hardness, higher tenacity, better wearing resistance, excellent corrosion resistance and desired histocompatibility. The present study was to investigate the efficiency of TNSMPC combined with cannulated compression screws in the treatment of comminuted patella fractures. METHODS: Between January 2014 and December 2017, 54 patients of C2 and C3 patella fractures underwent open reduction and internal fixation with TNSMPC combined with cannulated compression screws. All the patients got standard postoperative rehabilitation programs and were regularly followed up for at least 12 months after the operation. X-rays, knee functions and life quality were evaluated during the follow-up. RESULTS: All the patients achieved bone healing and recovery of knee function with low incidence of complications according to outcomes of X-rays and questionnaires. The average operation time and blood loss during surgery were 77.5 ± 25.12 min and 24.25 ± 4.70 ml respectively. The Knee Outcome Survey Activities of Daily Living Scale, the range of motion and the 36-item short-form heath survey after the operation were all improved. According to the Bostman’s criteria, the excellent to good rate was 92.6%. CONCLUSION: TNSMPC combined with cannulated compression screws is an effective internal fixation method for C2 and C3 patella fracture with excellent clinical outcomes. In addition, the operation does not increase extra technique difficulty or tissue damage relatively, which is worth promotion. BioMed Central 2020-07-31 /pmc/articles/PMC7395425/ /pubmed/32736553 http://dx.doi.org/10.1186/s12891-020-03536-3 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Yao, Chen
Sun, Jie
Wu, Jiancheng
Zhou, Zhenyu
Liu, Fan
Tao, Ran
Zhang, Yafeng
Clinical outcomes of Ti-Ni shape-memory patella concentrator combined with cannulated compression screws in the treatment of C2 and C3 patella fracture: a retrospective study of 54 cases
title Clinical outcomes of Ti-Ni shape-memory patella concentrator combined with cannulated compression screws in the treatment of C2 and C3 patella fracture: a retrospective study of 54 cases
title_full Clinical outcomes of Ti-Ni shape-memory patella concentrator combined with cannulated compression screws in the treatment of C2 and C3 patella fracture: a retrospective study of 54 cases
title_fullStr Clinical outcomes of Ti-Ni shape-memory patella concentrator combined with cannulated compression screws in the treatment of C2 and C3 patella fracture: a retrospective study of 54 cases
title_full_unstemmed Clinical outcomes of Ti-Ni shape-memory patella concentrator combined with cannulated compression screws in the treatment of C2 and C3 patella fracture: a retrospective study of 54 cases
title_short Clinical outcomes of Ti-Ni shape-memory patella concentrator combined with cannulated compression screws in the treatment of C2 and C3 patella fracture: a retrospective study of 54 cases
title_sort clinical outcomes of ti-ni shape-memory patella concentrator combined with cannulated compression screws in the treatment of c2 and c3 patella fracture: a retrospective study of 54 cases
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7395425/
https://www.ncbi.nlm.nih.gov/pubmed/32736553
http://dx.doi.org/10.1186/s12891-020-03536-3
work_keys_str_mv AT yaochen clinicaloutcomesoftinishapememorypatellaconcentratorcombinedwithcannulatedcompressionscrewsinthetreatmentofc2andc3patellafracturearetrospectivestudyof54cases
AT sunjie clinicaloutcomesoftinishapememorypatellaconcentratorcombinedwithcannulatedcompressionscrewsinthetreatmentofc2andc3patellafracturearetrospectivestudyof54cases
AT wujiancheng clinicaloutcomesoftinishapememorypatellaconcentratorcombinedwithcannulatedcompressionscrewsinthetreatmentofc2andc3patellafracturearetrospectivestudyof54cases
AT zhouzhenyu clinicaloutcomesoftinishapememorypatellaconcentratorcombinedwithcannulatedcompressionscrewsinthetreatmentofc2andc3patellafracturearetrospectivestudyof54cases
AT liufan clinicaloutcomesoftinishapememorypatellaconcentratorcombinedwithcannulatedcompressionscrewsinthetreatmentofc2andc3patellafracturearetrospectivestudyof54cases
AT taoran clinicaloutcomesoftinishapememorypatellaconcentratorcombinedwithcannulatedcompressionscrewsinthetreatmentofc2andc3patellafracturearetrospectivestudyof54cases
AT zhangyafeng clinicaloutcomesoftinishapememorypatellaconcentratorcombinedwithcannulatedcompressionscrewsinthetreatmentofc2andc3patellafracturearetrospectivestudyof54cases