Cargando…

Objective Quantification of Spontaneous Retinal Venous Pulsations Using a Novel Tablet-Based Ophthalmoscope

PURPOSE: Dynamic assessment of retinal vascular characteristics can aid in identifying glaucoma-specific biomarkers. More specifically, a loss of spontaneous retinal venous pulsations (SVPs) has been reported in glaucoma, but a lack of readily available tools has limited the ability to explore the f...

Descripción completa

Detalles Bibliográficos
Autores principales: Shariflou, Sahar, Agar, Ashish, Rose, Kathryn, Bowd, Christopher, Golzan, S. Mojtaba
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7396170/
https://www.ncbi.nlm.nih.gov/pubmed/32818106
http://dx.doi.org/10.1167/tvst.9.4.19
Descripción
Sumario:PURPOSE: Dynamic assessment of retinal vascular characteristics can aid in identifying glaucoma-specific biomarkers. More specifically, a loss of spontaneous retinal venous pulsations (SVPs) has been reported in glaucoma, but a lack of readily available tools has limited the ability to explore the full potential of SVP analysis in glaucoma assessment. Advancements in smart technology have paved the way for the development of portable, noninvasive, and inexpensive imaging modalities. By combining off-the-shelf optical elements and smart devices, the current study aims to determine whether SVPs can be detected and quantified using a novel tablet-based ophthalmoscope in glaucoma and glaucoma suspects. METHODS: Thirty patients, including 21 with confirmed glaucoma (9 men; average age 75 ± 8 years) and 9 glaucoma suspects (5 men; average age 64 ± 9 years), were studied. All patients had intraocular pressure measurements, Humphrey visual field assessment, optical coherence tomography, and a 10-second videoscopy of the retinal circulation. The retinal vasculature recordings (46° field of view at 30 frames per second) were analyzed to extract SVP amplitudes. RESULTS: SVPs were detected and quantified in 100% of patients with glaucoma and those with suspected glaucoma using the novel device. The average SVP amplitudes in glaucoma and glaucoma suspects were 42.6% ± 10.7% and 34% ± 6.7%, respectively. CONCLUSIONS: Our results suggest that a novel tablet-based ophthalmoscope can aid in documenting and objectively quantifying SVPs in all patients. TRANSLATIONAL RELEVANCE: Outcomes of this study provide an innovative, portable, noninvasive, and inexpensive solution for objective assessment of SVPs, which may have clinical relevance in glaucoma screening.