Cargando…
Study on FcγRn Electrochemical Receptor Sensor and Its Kinetics
Neonatal γ-immunoglobulin (IgG) Fc receptor (FcγRn) is a receptor that transports IgG across the intestinal mucosa, placenta, and mammary gland, ensuring the balance of IgG and albumin in the body. These functions of FcγRn depend on the intracellular signal transduction and activation caused by the...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7397135/ https://www.ncbi.nlm.nih.gov/pubmed/32674374 http://dx.doi.org/10.3390/molecules25143206 |
_version_ | 1783565710988935168 |
---|---|
author | Peng, Dandan Lu, Dingqiang Pang, Guangchang |
author_facet | Peng, Dandan Lu, Dingqiang Pang, Guangchang |
author_sort | Peng, Dandan |
collection | PubMed |
description | Neonatal γ-immunoglobulin (IgG) Fc receptor (FcγRn) is a receptor that transports IgG across the intestinal mucosa, placenta, and mammary gland, ensuring the balance of IgG and albumin in the body. These functions of FcγRn depend on the intracellular signal transduction and activation caused by the combination of its extracellular domain and IgG Fc domain. Nevertheless, there are still no kinetic studies on this interaction. Consequently, in the present study, we successfully constructed the human FcγRn (hFcγRn) electrochemical receptor sensor. The signal amplification system formed by chitosan nanogold-hFcγRn protein and horseradish peroxidase was used to simulate the cell signal amplification system in vivo, and the kinetic effects between seven IgG and hFcγRn receptors from different species were quantitatively measured. The results showed that the interaction of these seven IgGs with hFcγRn was similar to the catalytic kinetics of enzyme and substrate, and there was a ligand-receptor saturation effect. The order of the interconnect allosteric constants (K(a)), which is similar to the Michaelis constant (K(m)), was human IgG < bovine IgG < horse IgG < rabbit IgG < sheep IgG < donkey IgG < quail IgY. The results showed that hFcγRn had the strongest ability to transport human IgG, which was consistent with the evolution of the system. Therefore, our hFcγRn electrochemical receptor sensor can be used to measure and evaluate the interconnected allosteric network. It is also an essential parameter of the interaction between hFcγRn and different IgGs and, thus, provides a new detection and evaluation method for immunoemulsion, therapeutic monoclonal antibody therapy, heteroantibody treatment, and half-life research. |
format | Online Article Text |
id | pubmed-7397135 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-73971352020-08-05 Study on FcγRn Electrochemical Receptor Sensor and Its Kinetics Peng, Dandan Lu, Dingqiang Pang, Guangchang Molecules Article Neonatal γ-immunoglobulin (IgG) Fc receptor (FcγRn) is a receptor that transports IgG across the intestinal mucosa, placenta, and mammary gland, ensuring the balance of IgG and albumin in the body. These functions of FcγRn depend on the intracellular signal transduction and activation caused by the combination of its extracellular domain and IgG Fc domain. Nevertheless, there are still no kinetic studies on this interaction. Consequently, in the present study, we successfully constructed the human FcγRn (hFcγRn) electrochemical receptor sensor. The signal amplification system formed by chitosan nanogold-hFcγRn protein and horseradish peroxidase was used to simulate the cell signal amplification system in vivo, and the kinetic effects between seven IgG and hFcγRn receptors from different species were quantitatively measured. The results showed that the interaction of these seven IgGs with hFcγRn was similar to the catalytic kinetics of enzyme and substrate, and there was a ligand-receptor saturation effect. The order of the interconnect allosteric constants (K(a)), which is similar to the Michaelis constant (K(m)), was human IgG < bovine IgG < horse IgG < rabbit IgG < sheep IgG < donkey IgG < quail IgY. The results showed that hFcγRn had the strongest ability to transport human IgG, which was consistent with the evolution of the system. Therefore, our hFcγRn electrochemical receptor sensor can be used to measure and evaluate the interconnected allosteric network. It is also an essential parameter of the interaction between hFcγRn and different IgGs and, thus, provides a new detection and evaluation method for immunoemulsion, therapeutic monoclonal antibody therapy, heteroantibody treatment, and half-life research. MDPI 2020-07-14 /pmc/articles/PMC7397135/ /pubmed/32674374 http://dx.doi.org/10.3390/molecules25143206 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Peng, Dandan Lu, Dingqiang Pang, Guangchang Study on FcγRn Electrochemical Receptor Sensor and Its Kinetics |
title | Study on FcγRn Electrochemical Receptor Sensor and Its Kinetics |
title_full | Study on FcγRn Electrochemical Receptor Sensor and Its Kinetics |
title_fullStr | Study on FcγRn Electrochemical Receptor Sensor and Its Kinetics |
title_full_unstemmed | Study on FcγRn Electrochemical Receptor Sensor and Its Kinetics |
title_short | Study on FcγRn Electrochemical Receptor Sensor and Its Kinetics |
title_sort | study on fcγrn electrochemical receptor sensor and its kinetics |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7397135/ https://www.ncbi.nlm.nih.gov/pubmed/32674374 http://dx.doi.org/10.3390/molecules25143206 |
work_keys_str_mv | AT pengdandan studyonfcgrnelectrochemicalreceptorsensoranditskinetics AT ludingqiang studyonfcgrnelectrochemicalreceptorsensoranditskinetics AT pangguangchang studyonfcgrnelectrochemicalreceptorsensoranditskinetics |