Cargando…

Three-dimensional evaluation of bracket placement accuracy and excess bonding adhesive depending on indirect bonding technique and bracket geometry: an in-vitro study

BACKGROUND: This study aimed at comparing bracket placement and excess bonding adhesive depending on different indirect bonding (IDB) techniques and bracket geometries. METHODS: Four hundred eighty brackets without hook (WOH) and 360 with hook (WH) were placed on 60 plaster models. Three IDB techniq...

Descripción completa

Detalles Bibliográficos
Autores principales: Möhlhenrich, Stephan Christian, Alexandridis, Constantin, Peters, Florian, Kniha, Kristian, Modabber, Ali, Danesh, Golamreza, Fritz, Ulrike
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7397578/
https://www.ncbi.nlm.nih.gov/pubmed/32741369
http://dx.doi.org/10.1186/s13005-020-00231-5
Descripción
Sumario:BACKGROUND: This study aimed at comparing bracket placement and excess bonding adhesive depending on different indirect bonding (IDB) techniques and bracket geometries. METHODS: Four hundred eighty brackets without hook (WOH) and 360 with hook (WH) were placed on 60 plaster models. Three IDB techniques were tested: polyvinyl-siloxane vacuum-form (PVS-VF), polyvinyl-siloxane putty (PVS-putty), and translucence double-polyvinyl-siloxane (double-PVS). PVS-VF and PVS-putty were combined with chemically, and double-PVS was combined with light cured bonding adhesive. Virtual images of models before and after bracket transfer were generated, and computerized images were compared. Linear, angular deviations, and excess bonding adhesive were measured. RESULTS: Linear differences between the three groups were obtained for PVS-VF (WH: 1.08, SD 0.50 mm; WOH: 0.86, SD 0.25 mm), PVS-putty (WH: 0.73, SD 0.51 mm; WOH: 0.58, SD 0.28 mm), and double-PVS (WH: 0.65, SD 0.45 mm; WOH: 0.59, SD 0.33 mm) (P < 0.001). Hooks affected bracket placement accuracy in PVS-VF (P < 0.001) and PVS-putty (P = 0.029). Angular differences were observed for brackets WOH between the PVS-VF (0.64, SD 0.48°) and double-PVS group (0.92, SD 0.76°) (P < 0.001) and within double-PVS group (WH: 0.66, SD 0.51° vs. WOH: 0.92, SD 0.76°, P < 0.001). Highest amount of excess adhesive was obtained for PVS-putty group (WH: 6.54, SD 5.31 mm (2)). CONCLUSIONS: The double-PVS group revealed promising results with respect to transfer accuracy, whereas the PVS-VF group provided least excess bonding adhesive. Basically, hooks lead to lower precision and higher excess bonding adhesive. PVS trays for IDB generate high bracket placement accuracy. PVS-putty is the easiest to handle with and also the cheapest, but leads to large excess bonding adhesive, especially in combination with hooked brackets or tubes.