Finite Element Analysis-Based Vertebral Bone Strength Prediction Using MDCT Data: How Low Can We Go?

Objective: To study the impact of dose reduction in MDCT images through tube current reduction or sparse sampling on the vertebral bone strength prediction using finite element (FE) analysis for fracture risk assessment. Methods: Routine MDCT data covering lumbar vertebrae of 12 subjects (six male;...

Descripción completa

Detalles Bibliográficos
Autores principales: Rayudu, Nithin Manohar, Subburaj, Karupppasamy, Mei, Kai, Dieckmeyer, Michael, Kirschke, Jan S., Noël, Peter B., Baum, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7399039/
https://www.ncbi.nlm.nih.gov/pubmed/32849260
http://dx.doi.org/10.3389/fendo.2020.00442
_version_ 1783566069525381120
author Rayudu, Nithin Manohar
Subburaj, Karupppasamy
Mei, Kai
Dieckmeyer, Michael
Kirschke, Jan S.
Noël, Peter B.
Baum, Thomas
author_facet Rayudu, Nithin Manohar
Subburaj, Karupppasamy
Mei, Kai
Dieckmeyer, Michael
Kirschke, Jan S.
Noël, Peter B.
Baum, Thomas
author_sort Rayudu, Nithin Manohar
collection PubMed
description Objective: To study the impact of dose reduction in MDCT images through tube current reduction or sparse sampling on the vertebral bone strength prediction using finite element (FE) analysis for fracture risk assessment. Methods: Routine MDCT data covering lumbar vertebrae of 12 subjects (six male; six female; 74.70 ± 9.13 years old) were included in this study. Sparsely sampled and virtually reduced tube current–based MDCT images were computed using statistical iterative reconstruction (SIR) with reduced dose levels at 50, 25, and 10% of the tube current and original projections, respectively. Subject-specific static non-linear FE analyses were performed on vertebra models (L1, L2, and L3) 3-D-reconstructed from those dose-reduced MDCT images to predict bone strength. Coefficient of correlation (R(2)), Bland-Altman plots, and root mean square coefficient of variation (RMSCV) were calculated to find the variation in the FE-predicted strength at different dose levels, using high-intensity dose-based strength as the reference. Results: FE-predicted failure loads were not significantly affected by up to 90% dose reduction through sparse sampling (R(2) = 0.93, RMSCV = 8.6% for 50%; R(2) = 0.89, RMSCV = 11.90% for 75%; R(2) = 0.86, RMSCV = 11.30% for 90%) and up to 50% dose reduction through tube current reduction method (R(2) = 0.96, RMSCV = 12.06%). However, further reduction in dose with the tube current reduction method affected the ability to predict the failure load accurately (R(2) = 0.88, RMSCV = 22.04% for 75%; R(2) = 0.43, RMSCV = 54.18% for 90%). Conclusion: Results from this study suggest that a 50% radiation dose reduction through reduced tube current and a 90% radiation dose reduction through sparse sampling can be used to predict vertebral bone strength. Our findings suggest that the sparse sampling–based method performs better than the tube current–reduction method in generating images required for FE-based bone strength prediction models.
format Online
Article
Text
id pubmed-7399039
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-73990392020-08-25 Finite Element Analysis-Based Vertebral Bone Strength Prediction Using MDCT Data: How Low Can We Go? Rayudu, Nithin Manohar Subburaj, Karupppasamy Mei, Kai Dieckmeyer, Michael Kirschke, Jan S. Noël, Peter B. Baum, Thomas Front Endocrinol (Lausanne) Endocrinology Objective: To study the impact of dose reduction in MDCT images through tube current reduction or sparse sampling on the vertebral bone strength prediction using finite element (FE) analysis for fracture risk assessment. Methods: Routine MDCT data covering lumbar vertebrae of 12 subjects (six male; six female; 74.70 ± 9.13 years old) were included in this study. Sparsely sampled and virtually reduced tube current–based MDCT images were computed using statistical iterative reconstruction (SIR) with reduced dose levels at 50, 25, and 10% of the tube current and original projections, respectively. Subject-specific static non-linear FE analyses were performed on vertebra models (L1, L2, and L3) 3-D-reconstructed from those dose-reduced MDCT images to predict bone strength. Coefficient of correlation (R(2)), Bland-Altman plots, and root mean square coefficient of variation (RMSCV) were calculated to find the variation in the FE-predicted strength at different dose levels, using high-intensity dose-based strength as the reference. Results: FE-predicted failure loads were not significantly affected by up to 90% dose reduction through sparse sampling (R(2) = 0.93, RMSCV = 8.6% for 50%; R(2) = 0.89, RMSCV = 11.90% for 75%; R(2) = 0.86, RMSCV = 11.30% for 90%) and up to 50% dose reduction through tube current reduction method (R(2) = 0.96, RMSCV = 12.06%). However, further reduction in dose with the tube current reduction method affected the ability to predict the failure load accurately (R(2) = 0.88, RMSCV = 22.04% for 75%; R(2) = 0.43, RMSCV = 54.18% for 90%). Conclusion: Results from this study suggest that a 50% radiation dose reduction through reduced tube current and a 90% radiation dose reduction through sparse sampling can be used to predict vertebral bone strength. Our findings suggest that the sparse sampling–based method performs better than the tube current–reduction method in generating images required for FE-based bone strength prediction models. Frontiers Media S.A. 2020-07-28 /pmc/articles/PMC7399039/ /pubmed/32849260 http://dx.doi.org/10.3389/fendo.2020.00442 Text en Copyright © 2020 Rayudu, Subburaj, Mei, Dieckmeyer, Kirschke, Noël and Baum. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Endocrinology
Rayudu, Nithin Manohar
Subburaj, Karupppasamy
Mei, Kai
Dieckmeyer, Michael
Kirschke, Jan S.
Noël, Peter B.
Baum, Thomas
Finite Element Analysis-Based Vertebral Bone Strength Prediction Using MDCT Data: How Low Can We Go?
title Finite Element Analysis-Based Vertebral Bone Strength Prediction Using MDCT Data: How Low Can We Go?
title_full Finite Element Analysis-Based Vertebral Bone Strength Prediction Using MDCT Data: How Low Can We Go?
title_fullStr Finite Element Analysis-Based Vertebral Bone Strength Prediction Using MDCT Data: How Low Can We Go?
title_full_unstemmed Finite Element Analysis-Based Vertebral Bone Strength Prediction Using MDCT Data: How Low Can We Go?
title_short Finite Element Analysis-Based Vertebral Bone Strength Prediction Using MDCT Data: How Low Can We Go?
title_sort finite element analysis-based vertebral bone strength prediction using mdct data: how low can we go?
topic Endocrinology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7399039/
https://www.ncbi.nlm.nih.gov/pubmed/32849260
http://dx.doi.org/10.3389/fendo.2020.00442
work_keys_str_mv AT rayudunithinmanohar finiteelementanalysisbasedvertebralbonestrengthpredictionusingmdctdatahowlowcanwego
AT subburajkarupppasamy finiteelementanalysisbasedvertebralbonestrengthpredictionusingmdctdatahowlowcanwego
AT meikai finiteelementanalysisbasedvertebralbonestrengthpredictionusingmdctdatahowlowcanwego
AT dieckmeyermichael finiteelementanalysisbasedvertebralbonestrengthpredictionusingmdctdatahowlowcanwego
AT kirschkejans finiteelementanalysisbasedvertebralbonestrengthpredictionusingmdctdatahowlowcanwego
AT noelpeterb finiteelementanalysisbasedvertebralbonestrengthpredictionusingmdctdatahowlowcanwego
AT baumthomas finiteelementanalysisbasedvertebralbonestrengthpredictionusingmdctdatahowlowcanwego