Reliability of a Robotic Knee Testing Tool to Assess Rotational Stability of the Knee Joint in Healthy Female and Male Volunteers

BACKGROUND: Several clinical tests exist to assess knee laxity. Although these assessments are the predominant tools of diagnosis, they are subjective and rely on the experience of the clinician. The robotic knee testing (RKT) device has been developed to quantitatively and objectively measure rotat...

Descripción completa

Detalles Bibliográficos
Autores principales: Beckley, Samantha, Stinton, Shaun, Lesosky, Maia, September, Alison, Collins, Malcolm, Branch, Thomas, Posthumus, Mike
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7399727/
https://www.ncbi.nlm.nih.gov/pubmed/32748169
http://dx.doi.org/10.1186/s40798-020-00266-7
_version_ 1783566198459334656
author Beckley, Samantha
Stinton, Shaun
Lesosky, Maia
September, Alison
Collins, Malcolm
Branch, Thomas
Posthumus, Mike
author_facet Beckley, Samantha
Stinton, Shaun
Lesosky, Maia
September, Alison
Collins, Malcolm
Branch, Thomas
Posthumus, Mike
author_sort Beckley, Samantha
collection PubMed
description BACKGROUND: Several clinical tests exist to assess knee laxity. Although these assessments are the predominant tools of diagnosis, they are subjective and rely on the experience of the clinician. The robotic knee testing (RKT) device has been developed to quantitatively and objectively measure rotational knee laxity. The purpose of this study was primarily to determine the intra-tester reliability of rotational knee laxity and slack, the amount of rotation occurring between the two turning points of the load deformation curve, measured by the RKT device and investigate the differences between female and male measurements. METHODS: Ninety-one healthy and moderately active volunteers took part in the study, of which twenty-five participated in the reliability study. Tibial rotation was performed using a servomotor to a torque of 6 N m, while measurements of motion in all 6° of freedom were collected. Reliability measurements were collected over 5 days at similar times of the day. Intra-class correlation coefficient (ICC) values and standard error of measurement (SEM) were determined across the load deformation curves. Linear mixed effects modelling was used to further assess the reliability of the measurement of external and internal tibial rotation using features of the curve (internal/external rotational laxity and slack). Measurements of internal/external rotational laxity and slack were compared between the sexes using the Student t test. RESULTS: Pointwise axial rotation measurements of the tibia had good reliability [ICC (2,1) 0.83–0.89], while reliability of the secondary motions ranged between poor and good [ICC (2,1) 0.31–0.89]. All SEMs were less than 0.3°. Most of the variation of the curve features were accounted for by inter-subject differences (56.2–77.8%) and showed moderate to good reliability. Comparison of the right legs of the sexes revealed that females had significantly larger amounts of internal rotation laxity (females 6.1 ± 1.3° vs males 5.6 ± 0.9°, p = 0.037), external rotation laxity (females 6.0 ± 1.6° vs males 5.0 ± 1.2°, p = 0.002) and slack (females 19.2 ± 4.2° vs males 16.6 ± 2.9°, p = 0.003). Similar results were seen within the left legs. CONCLUSIONS: Overall, the RKT is a reliable and precise tool to assess the rotational laxity of the knee joint in healthy individuals. Finally, greater amounts of laxity and slack were also reported for females.
format Online
Article
Text
id pubmed-7399727
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-73997272020-08-13 Reliability of a Robotic Knee Testing Tool to Assess Rotational Stability of the Knee Joint in Healthy Female and Male Volunteers Beckley, Samantha Stinton, Shaun Lesosky, Maia September, Alison Collins, Malcolm Branch, Thomas Posthumus, Mike Sports Med Open Original Research Article BACKGROUND: Several clinical tests exist to assess knee laxity. Although these assessments are the predominant tools of diagnosis, they are subjective and rely on the experience of the clinician. The robotic knee testing (RKT) device has been developed to quantitatively and objectively measure rotational knee laxity. The purpose of this study was primarily to determine the intra-tester reliability of rotational knee laxity and slack, the amount of rotation occurring between the two turning points of the load deformation curve, measured by the RKT device and investigate the differences between female and male measurements. METHODS: Ninety-one healthy and moderately active volunteers took part in the study, of which twenty-five participated in the reliability study. Tibial rotation was performed using a servomotor to a torque of 6 N m, while measurements of motion in all 6° of freedom were collected. Reliability measurements were collected over 5 days at similar times of the day. Intra-class correlation coefficient (ICC) values and standard error of measurement (SEM) were determined across the load deformation curves. Linear mixed effects modelling was used to further assess the reliability of the measurement of external and internal tibial rotation using features of the curve (internal/external rotational laxity and slack). Measurements of internal/external rotational laxity and slack were compared between the sexes using the Student t test. RESULTS: Pointwise axial rotation measurements of the tibia had good reliability [ICC (2,1) 0.83–0.89], while reliability of the secondary motions ranged between poor and good [ICC (2,1) 0.31–0.89]. All SEMs were less than 0.3°. Most of the variation of the curve features were accounted for by inter-subject differences (56.2–77.8%) and showed moderate to good reliability. Comparison of the right legs of the sexes revealed that females had significantly larger amounts of internal rotation laxity (females 6.1 ± 1.3° vs males 5.6 ± 0.9°, p = 0.037), external rotation laxity (females 6.0 ± 1.6° vs males 5.0 ± 1.2°, p = 0.002) and slack (females 19.2 ± 4.2° vs males 16.6 ± 2.9°, p = 0.003). Similar results were seen within the left legs. CONCLUSIONS: Overall, the RKT is a reliable and precise tool to assess the rotational laxity of the knee joint in healthy individuals. Finally, greater amounts of laxity and slack were also reported for females. Springer International Publishing 2020-08-03 /pmc/articles/PMC7399727/ /pubmed/32748169 http://dx.doi.org/10.1186/s40798-020-00266-7 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Original Research Article
Beckley, Samantha
Stinton, Shaun
Lesosky, Maia
September, Alison
Collins, Malcolm
Branch, Thomas
Posthumus, Mike
Reliability of a Robotic Knee Testing Tool to Assess Rotational Stability of the Knee Joint in Healthy Female and Male Volunteers
title Reliability of a Robotic Knee Testing Tool to Assess Rotational Stability of the Knee Joint in Healthy Female and Male Volunteers
title_full Reliability of a Robotic Knee Testing Tool to Assess Rotational Stability of the Knee Joint in Healthy Female and Male Volunteers
title_fullStr Reliability of a Robotic Knee Testing Tool to Assess Rotational Stability of the Knee Joint in Healthy Female and Male Volunteers
title_full_unstemmed Reliability of a Robotic Knee Testing Tool to Assess Rotational Stability of the Knee Joint in Healthy Female and Male Volunteers
title_short Reliability of a Robotic Knee Testing Tool to Assess Rotational Stability of the Knee Joint in Healthy Female and Male Volunteers
title_sort reliability of a robotic knee testing tool to assess rotational stability of the knee joint in healthy female and male volunteers
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7399727/
https://www.ncbi.nlm.nih.gov/pubmed/32748169
http://dx.doi.org/10.1186/s40798-020-00266-7
work_keys_str_mv AT beckleysamantha reliabilityofarobotickneetestingtooltoassessrotationalstabilityofthekneejointinhealthyfemaleandmalevolunteers
AT stintonshaun reliabilityofarobotickneetestingtooltoassessrotationalstabilityofthekneejointinhealthyfemaleandmalevolunteers
AT lesoskymaia reliabilityofarobotickneetestingtooltoassessrotationalstabilityofthekneejointinhealthyfemaleandmalevolunteers
AT septemberalison reliabilityofarobotickneetestingtooltoassessrotationalstabilityofthekneejointinhealthyfemaleandmalevolunteers
AT collinsmalcolm reliabilityofarobotickneetestingtooltoassessrotationalstabilityofthekneejointinhealthyfemaleandmalevolunteers
AT branchthomas reliabilityofarobotickneetestingtooltoassessrotationalstabilityofthekneejointinhealthyfemaleandmalevolunteers
AT posthumusmike reliabilityofarobotickneetestingtooltoassessrotationalstabilityofthekneejointinhealthyfemaleandmalevolunteers