Cargando…

Accuracy of Dynamic Navigation System Workflow for Implant Supported Full Arch Prosthesis: A Case Series

A minimally invasive implant treatment approach for future full arch implant prosthetic rehabilitations of trophic jaws represents a challenge. An optimal implant planning is strongly related with an accurate merge of the prosthetic information and the radiographic data. To comply with that, most co...

Descripción completa

Detalles Bibliográficos
Autores principales: Stefanelli, Luigi V., Mandelaris, George A., Franchina, Alessio, Pranno, Nicola, Pagliarulo, Michele, Cera, Francesca, Maltese, Fabio, De Angelis, Francesca, Di Carlo, Stefano
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7400369/
https://www.ncbi.nlm.nih.gov/pubmed/32668790
http://dx.doi.org/10.3390/ijerph17145038
_version_ 1783566347862540288
author Stefanelli, Luigi V.
Mandelaris, George A.
Franchina, Alessio
Pranno, Nicola
Pagliarulo, Michele
Cera, Francesca
Maltese, Fabio
De Angelis, Francesca
Di Carlo, Stefano
author_facet Stefanelli, Luigi V.
Mandelaris, George A.
Franchina, Alessio
Pranno, Nicola
Pagliarulo, Michele
Cera, Francesca
Maltese, Fabio
De Angelis, Francesca
Di Carlo, Stefano
author_sort Stefanelli, Luigi V.
collection PubMed
description A minimally invasive implant treatment approach for future full arch implant prosthetic rehabilitations of trophic jaws represents a challenge. An optimal implant planning is strongly related with an accurate merge of the prosthetic information and the radiographic data. To comply with that, most computer aided implantology (CAI) systems require additional steps, as radiographic stents or fiducial markers to overlap digital jaw scans to cone beam computed tomography (CBCT) data. Using dynamic CAI, residual teeth (up to three) make it possible for the merge to avoid new radiographic scans. An additional challenge is the treatment involving immediate implants compared with delayed implants placed into healed bone. As for other static CAI systems, the operator’s experience and the quality of the CBCT data make the planning affordable and secure the entire implants placement procedure. The literature reports accuracies in terms of comparison between placed implants and planned implants, following a double CBCT approach, based on radiographic volume overlapping. Thirteen consecutive future totally edentulous patients (77 implants), divided into two groups (group A: 3–4 teeth traced; group B: 5–6 teeth traced) requiring a full arch implant prosthetic rehabilitation were included in the reported case series. A dynamic CAI was used to plan and to place all implants following all the recommended digital steps. The software used provided a tool (Trace and Place) that made the merge between X-ray views of the residual teeth and their own positions possible. This method definitely registered that teeth positions comply with the required accuracy live check. After implants placement, a post-operative CBCT was taken in order to evaluate the deviations of the achieved implants at coronal, apical, and depth level as well as angular deviations. Statistically significant radiological mean difference between the two groups was found in the coronal position of implants (0.26 mm, p < 0.001), in the apical position of implants (0.29 mm, p < 0.001), in the depth of implants (0.16 mm, p = 0.022), and in the angular deviation (0.7, p = 0.004). The use of the TaP technology for the treatment of the patients with at least three stable teeth that need to be removed for a totally implant prosthetic treatment is a promising technique. The performed accuracy analysis demonstrated that this digital protocol can be used without a loss of accuracy of the achieved implants compared to planned ones.
format Online
Article
Text
id pubmed-7400369
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-74003692020-08-23 Accuracy of Dynamic Navigation System Workflow for Implant Supported Full Arch Prosthesis: A Case Series Stefanelli, Luigi V. Mandelaris, George A. Franchina, Alessio Pranno, Nicola Pagliarulo, Michele Cera, Francesca Maltese, Fabio De Angelis, Francesca Di Carlo, Stefano Int J Environ Res Public Health Article A minimally invasive implant treatment approach for future full arch implant prosthetic rehabilitations of trophic jaws represents a challenge. An optimal implant planning is strongly related with an accurate merge of the prosthetic information and the radiographic data. To comply with that, most computer aided implantology (CAI) systems require additional steps, as radiographic stents or fiducial markers to overlap digital jaw scans to cone beam computed tomography (CBCT) data. Using dynamic CAI, residual teeth (up to three) make it possible for the merge to avoid new radiographic scans. An additional challenge is the treatment involving immediate implants compared with delayed implants placed into healed bone. As for other static CAI systems, the operator’s experience and the quality of the CBCT data make the planning affordable and secure the entire implants placement procedure. The literature reports accuracies in terms of comparison between placed implants and planned implants, following a double CBCT approach, based on radiographic volume overlapping. Thirteen consecutive future totally edentulous patients (77 implants), divided into two groups (group A: 3–4 teeth traced; group B: 5–6 teeth traced) requiring a full arch implant prosthetic rehabilitation were included in the reported case series. A dynamic CAI was used to plan and to place all implants following all the recommended digital steps. The software used provided a tool (Trace and Place) that made the merge between X-ray views of the residual teeth and their own positions possible. This method definitely registered that teeth positions comply with the required accuracy live check. After implants placement, a post-operative CBCT was taken in order to evaluate the deviations of the achieved implants at coronal, apical, and depth level as well as angular deviations. Statistically significant radiological mean difference between the two groups was found in the coronal position of implants (0.26 mm, p < 0.001), in the apical position of implants (0.29 mm, p < 0.001), in the depth of implants (0.16 mm, p = 0.022), and in the angular deviation (0.7, p = 0.004). The use of the TaP technology for the treatment of the patients with at least three stable teeth that need to be removed for a totally implant prosthetic treatment is a promising technique. The performed accuracy analysis demonstrated that this digital protocol can be used without a loss of accuracy of the achieved implants compared to planned ones. MDPI 2020-07-13 2020-07 /pmc/articles/PMC7400369/ /pubmed/32668790 http://dx.doi.org/10.3390/ijerph17145038 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Stefanelli, Luigi V.
Mandelaris, George A.
Franchina, Alessio
Pranno, Nicola
Pagliarulo, Michele
Cera, Francesca
Maltese, Fabio
De Angelis, Francesca
Di Carlo, Stefano
Accuracy of Dynamic Navigation System Workflow for Implant Supported Full Arch Prosthesis: A Case Series
title Accuracy of Dynamic Navigation System Workflow for Implant Supported Full Arch Prosthesis: A Case Series
title_full Accuracy of Dynamic Navigation System Workflow for Implant Supported Full Arch Prosthesis: A Case Series
title_fullStr Accuracy of Dynamic Navigation System Workflow for Implant Supported Full Arch Prosthesis: A Case Series
title_full_unstemmed Accuracy of Dynamic Navigation System Workflow for Implant Supported Full Arch Prosthesis: A Case Series
title_short Accuracy of Dynamic Navigation System Workflow for Implant Supported Full Arch Prosthesis: A Case Series
title_sort accuracy of dynamic navigation system workflow for implant supported full arch prosthesis: a case series
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7400369/
https://www.ncbi.nlm.nih.gov/pubmed/32668790
http://dx.doi.org/10.3390/ijerph17145038
work_keys_str_mv AT stefanelliluigiv accuracyofdynamicnavigationsystemworkflowforimplantsupportedfullarchprosthesisacaseseries
AT mandelarisgeorgea accuracyofdynamicnavigationsystemworkflowforimplantsupportedfullarchprosthesisacaseseries
AT franchinaalessio accuracyofdynamicnavigationsystemworkflowforimplantsupportedfullarchprosthesisacaseseries
AT prannonicola accuracyofdynamicnavigationsystemworkflowforimplantsupportedfullarchprosthesisacaseseries
AT pagliarulomichele accuracyofdynamicnavigationsystemworkflowforimplantsupportedfullarchprosthesisacaseseries
AT cerafrancesca accuracyofdynamicnavigationsystemworkflowforimplantsupportedfullarchprosthesisacaseseries
AT maltesefabio accuracyofdynamicnavigationsystemworkflowforimplantsupportedfullarchprosthesisacaseseries
AT deangelisfrancesca accuracyofdynamicnavigationsystemworkflowforimplantsupportedfullarchprosthesisacaseseries
AT dicarlostefano accuracyofdynamicnavigationsystemworkflowforimplantsupportedfullarchprosthesisacaseseries